Omega Products PX1004L1-1.5KAV User Manual

ELECTRICAL CONNECTOR TWIST-LOCK PCIH0-10-6P (101) OR EQUIVALENT
61 (2.40)
17.47 ±0.25 (0.688 ±0.01) (WRENCH FLATS)
6.35 ±0.25
(0.25 ±0.01)
PRESSURE FITTING MS33656-4
Functions POSITIVE INPUT POSITIVE OUTPUT NEGATIVE OUTPUT NEGATIVE INPUT SHORTED TO "D" SHORTED TO "C"
Pins
A B C D E F
SCHEMATIC
25.7 (1.01) DIA. MAX.
61 (2.40)
17.47 ±0.25 (0.688 ±0.01) (WRENCH FLATS)
6.35 ±0.25
(0.25 ±0.01)
PRESSURE FITTING MS33656-4
Functions POSITIVE INPUT POSITIVE OUTPUT NEGATIVE OUTPUT NEGATIVE INPUT GROUND (CASE)
SCHEMATIC
25.7 (1.01) DIA. MAX
Cable Color
RED STRIPE
YELLOW STRIPE
BLUE STRIPE
WHITE
BROWN STRIPE
762 (30.0)
MIN.
HIGH- AND VERY-HIGH-TEMPERATURE PRESSURE TRANSDUCERS
PX1004/PX1009 Series
mV/V Output 0-15 to 0-10,000 psi 0-1 to 0-700 bar
1 bar = 14.5 psi 1 kg/cm2= 14.22 psi 1 atmosphere = 14.7 psi = 29.93 inHg = 760.2 mmHg = 1.014 bar
Starts at
$
1850
Two Versions That
Operate from -54 to 232°C (-65 to 450°F) (PX1004) or -54 to 343°C (-65 to 650°F) (PX1009)
High PerformanceProven High ReliabilityExceptional Calibration
Stability
Applications
Engine and Test StandsHigh-Temperature TestingProcess MonitoringGround Support
Equipment
High-Temperature
Geothermal Generators
PX1009L0-1KAV, $2500,
shown actual size.
tandard
S
OMEGA’s thin-film technology makes this premium performance possible. The strain gages are sputter-deposited, forming a molecular bond with the substrate. There is virtually no shift, drift, or creep to cause the transducer’s calibration to change. The all-welded stainless steel pressure cavity and double-isolated case ensure pressure integrity and reliability in adverse environments.
These high-temperature transducers are available in many standard ranges from 15 psi to 10,000 psi. A NIST-traceable calibration record is available for these units.
SPECIFICATIONS
Excitation: 10 Vdc Full Range Output:
30 mV nominal, 26 mV minimum
Residual Unbalance:
0 mV ±5% FSO at zero pressure
Input Resistance: 400 nominal Output Resistance: 400 nominal
PX1004
PX1004L1-1KAV, $1850,
shown actual size.
Insulation Resistance:
PX1004:
100 M or greater @ 45 Vdc
PX1009: 50 M or greater @ 45 Vdc
Electrical Connections:
PX1004: PCIH0-10-6P or
equivalent PX1009: Color-coded pigtail leads,
0.8 m (30") long, minimum
Sensing Element:
4-active-arm bridge using sputter­deposited thin-film elements.
Accuracy: Combined linearity, hysteresis and repeatability: ±0.25% FSO, BSL (over the compensated temperature range)
[Note: Performance is determined at 25°C ±1°C (77°F ±2°F), open circuit, rated excitation, unless otherwise specified]
Operating Temp Range:
PX1004: -54 to 232°C (-65 to 450°F) PX1009: -54 to 343°C (-65 to 650°F)
Compensated Temp Range:
PX1004: 24 to 204°C (75 to 400°F) PX1009: 24 to 316°C (75 to 600°F)
PX1009
OMEGA’s PX1004 and PX1009 sputtered thin-film pressure transducers are designed for high-temperature service. These instruments can operate in temperatures from -54 to 232°C or 343°C (-65 to 450°F or 650°F).
Yet even in these extreme temperatures, they provide outstanding accuracy, long-term calibration stability, and reliability. Static accuracy is ±0.25%, and thermal zero and sensitivity shifts over their compensated ranges are less than ±0.01%/°F.
Dimensions: mm (in)
B-75
HIGH AND VERY HIGH TEMPERATURE PRESSURE TRANSDUCERS
Thermal Effects:
Span: ±0.01% FSO/°F Zero: ±0.01% FSO/°F
Natural Frequency:
50 kHz at 5000 psi decreasing logarithmically to 5 kHz at 15 psi Vibration Sensitivity: At 35 g peak from 10 Hz to 2000 Hz (limited to
1
2" D.A.), the output shall not exceed:
15 psi 0.04% FSO/g 0.15% FSO/g 50 psi 0.02% FSO/g 0.07% FSO/g 100 psi 0.015% FSO/g 0.05% FSO/g 500 psi 0.006% FSO/g 0.02% FSO/g 1000 psi 0.003% FSO/g 0.02% FSO/g
PX1004 PX1009
Shock: 100 g, 11 ms half sine wave
without calibration shift or damage
Humidity:
Per MIL-STD-810, Method 507.1 Standard ranges: 0 to 15, 25, 50, 100, 250, 500, 1000, 1500, 2000, 2500, 5000 and 10,000 psia. Sealed gage available in ranges of 100 psi and above.
Proof Pressure:
PX1004: 200% of rated pressure PX1009: 150% of rated pressure
Burst Pressure:
PX1004: 300% of rated pressure PX1009: 200% of rated pressure
Wetted Parts: 17-4 PH vacuum melt or
15-5 stainless steel
MOST POPULAR MODELS HIGHLIGHTED!
Pressure Fitting:
7
16-20 male per MS33656-4
Mounting Isolation: Case isolation ensures that the sensing element will not be affected by external stresses
Mating Connector (PX1004):
PCS06E-10-6S(SR) (sold separately) Weight: 145 g (5 oz) maximum
PX1004 Mating Connector
PCS06E-10-6S(SR)
$135
To Order (Specify Model Number)
RANGE MODEL NO. PX1004 PRICE MODEL NO. PX1009 PRICE COMPATIBLE METERS* ABSOLUTE PRESSURE (All Ranges Available in Sealed Gage Pressure)
0 to 15 psi 0 to 1.0 bar PX1004L1-015AV $1850 PX1009L0-015AV $2500 DP41-S, DP25B-S 0 to 25 psi 0 to 1.7 bar PX1004L1-025AV 1850 PX1009L0-025AV 2500 DP41-S, DP25B-S 0 to 50 psi 0 to 3.4 bar PX1004L1-050AV 1850 PX1009L0-050AV 2500 DP41-S, DP25B-S 0 to 100 psi 0 to 6.9 bar PX1004L1-100AV 1850 PX1009L0-100AV 2500 DP41-S, DP25B-S 0 to 250 psi 0 to 17.2 bar PX1004L1-250AV 1850 PX1009L0-250AV 2500 DP41-S, DP25B-S 0 to 500 psi 0 to 34.5 bar PX1004L1-500AV 1850 PX1009L0-500AV 2500 DP41-S, DP25B-S 0 to 1000 psi 0 to 68.9 bar PX1004L1-1KAV 1850 PX1009L0-1KAV 2500 DP41-S, DP25B-S 0 to 1500 psi 0 to 103 bar PX1004L1-1.5KAV 1850 PX1009L0-1.5KAV 2500 DP41-S, DP25B-S 0 to 2000 psi 0 to 138 bar PX1004L1-2KAV 1850 PX1009L0-2KAV 2500 DP41-S, DP25B-S 0 to 2500 psi 0 to 172 bar PX1004L1-2.5KAV 1850 PX1009L0-2.5KAV 2500 DP41-S, DP25B-S 0 to 5000 psi 0 to 345 bar PX1004L1-5KAV 1850 PX1009L0-5KAV 2500 DP41-S, DP25B-S 0 to 10,000 psi 0 to 689 bar PX1004L1-10KAV 1850 PX1009L0-10KAV 2500 DP41-S, DP25B-S
Comes complete with 5-point calibration. To order sealed gage pressure, replace “A” in model number with “S” (no extra charge). Ordering Examples: PX1004L1-100AV, 100 psi absolute pressure transducer with male pressure connection per MS33656-4 and
PCHI0-10-6P electrical connector, $1850. PCS06E-10-6S(SR), mating connector (sold separately), $135. PX1009L0-1KSV, 1000 psi sealed gage pressure transducer with MS33656-4 male pressure connection and 0.8 m (30") high-temperature cable, $2500.
CUSTOM CONFIGURATIONS
PRESSURE ELECTRICAL RANGE
PX1004/1009 PORT CONNECTION UNITS OUTPUT OPTIONS SERIES [ 1 ] [ 2 ] [ 3 ] [ 4 ] [ 5 ] [ 6 ]
L = MS33656-4
PX1004 only 1 = PCIH0-10-6P
Connector (or equal). Mating connector (sold separately), order
PCS06E-10-6S(SR) $135.
PX1009 only 0 = color-coded
cable, 0.8 m (30") min.
Metric ranges available – Consult Engineering.
Ordering Examples: PX1004L1-100AV, MS33656-4 male pressure port, twist-lock connector, 100 psi absolute pressure range and mV/V output, $1850. PCS06E-10-6S(SR), mating connector (sold separately), $135. PX1004L1-015SV, MS33656-4 male pressure port, twist-lock connector, 15 psi sealed gage pressure range and mV/V output, $1850. PCS06E-10-6S(SR), mating connector (sold separately), $135. PX1009L1-1KSV-CAL11, MS33656-4 male pressure port, 0.8 m (30") high-temperature cable, 1000 psi sealed gage pressure range, mV/V output and optional 11-point NIST-traceable calibration, $2500 + 250 = $2750.
See section D for compatible meters. Metric ranges available – Consult Engineering.
*
ACCESSORY
MODEL NO. PRICE DESCRIPTION
PCS06E-10-6S(SR) $135 Mating connector for PX1004 transducers
015 psi 025 050 100 250 500 1K
1.5K 2K
2.5K 5K 10K
A A A A, S A, S A, S A, S A, S A, S A, S A, S A, S
V = mV/V Output Base Price PX1004:
$1850
Base Price PX1009:
$2500
To order a custom configuration:
1. Select a pressure port
2. Select electrical connection
3. Select a pressure range
4. Select pressure units
CAL11 = 11-point
traceable calibration
+$250
5. Select output
6. Select options and agency approvals
NIST-
PRESSURE TRANSDUCERS
MILLIVOLT OUTPUT
B
B-76
Loading...