Omega Products PX02K5-010AI User Manual

HIGH-ACCURACY PRESSURE TRANSMITTER
FM
A
PPROVED
PX02 SERIES
4 to 20 mA Output 0-2 to 0-30,000 psi 0-150 mbar to 0-2000 bar
1 bar = 14.5 psi 1 kg/cm2= 14.22 psi 1 atmosphere = 14.7 psi = 29.93 inHg = 760.2 mmHg = 1.014 bar
PX02K5-050GI, $650, shown
Starts at
smaller than actual size.
$
650
MOST POPULAR
Standard
On Request
High-Accuracy, NIST-
Traceable Calibration
FM Intrinsically Safe,
Standard
All Stainless Steel
Construction
Hermetically Sealed
Design for Harsh Environments
Available in Gage,
Absolute, Sealed Gage, psi, and Metric Ranges
Optional Pressure Ports
to Fit Most Industrial Applications
OMEGA’s PX02 Series comprises high-accuracy industrial pressure transmitters. All stainless steel construction and a sealed case make the PX02 suitable for harsh environments. FM Intrinsically Safe approvals are standard. A broad temperature-compensated range of 16 to 71°C (60 to 160°F) and a high operating range to 121°C (250°F) provide stability in applications with fluctuating temperatures.
The PX02 is available in gage, absolute, or sealed models, as well as in psi or metric ranges.
To Order (Specify Model Number)
Models with 7⁄16-20 UNF Connection/Amplifier Housing RANGE MODEL NO. PRICE COMPATIBLE METERS ABSOLUTE PRESSURE (All Ranges Available in Absolute Pressure)
0 to 10 psi 0 to 0.69 bar PX02K5-010AI $765 0 to 15 psi 0 to 1.0 bar PX02K5-015AI 765 0 to 20 psi 0 to 1.4 bar PX02K5-020AI 765 0 to 25 psi 0 to 1.7 bar PX02K5-025AI 765 0 to 50 psi 0 to 3.4 bar PX02K5-050AI 725
GAGE PRESSURE (All Ranges Also Available in Sealed Gage Pressure)
0 to 2 psi 0 to 0.14 bar PX02K5-002GI $715 0 to 5 psi 0 to 0.34 bar PX02K5-005GI 715 0 to 10 psi 0 to 0.69 bar PX02K5-010GI 715 0 to 15 psi 0 to 1.0 bar PX02K5-015GI 715 0 to 50 psi 0 to 3.4 bar PX02K5-050GI 650 0 to 75 psi 0 to 5.2 bar PX02K5-075GI 650 0 to 100 psi 0 to 6.9 bar PX02K5-100GI 650 0 to 200 psi 0 to 13.8 bar PX02K5-200GI 650 0 to 300 psi 0 to 20.7 bar PX02K5-300GI 650 0 to 500 psi 0 to 34.5 bar PX02K5-500GI 650 0 to 1000 psi 0 to 68.9 bar PX02K5-1KGI 650 0 to 1500 psi 0 to 103 bar PX02K5-1.5KGI 650 0 to 2000 psi 0 to 138 bar PX02K5-2KGI 650 0 to 3500 psi 0 to 241 bar PX02K5-3.5KGI 650 0 to 5000 psi 0 to 345 bar PX02K5-5KGI 650 0 to 7500 psi 0 to 517 bar PX02K5-7.5KGI 650 0 to 10,000** psi 0 to 689 bar PX02S5-10KGI 750 0 to 20,000** psi 0 to 1379 bar PX02S5-20KGI 750 0 to 30,000** psi 0 to 2068 bar PX02S5-30KGI 750
Comes complete with 5-point NIST traceable calibration. Metric ranges available – consult Engineering.
4-digit meter, counts in increments of 10.
*
For absolute pressure, replace “G” in model number with “A”, add $50 100 psi. For sealed gage pressure, replace “G” in model number with “S” (no charge unless indicated).
Ordering Examples: PX02K5-1KGI, 1000 psi gage transducer with 4 to 20 mA output, amplifier housing connections and 7⁄16-20 UNF female pressure connection, $650. PX02K5-015AI, 15 psi absolute transducer with 4 to 20 mA output, amplifier housing connections and 7⁄16-20 UNF female pressure connection, $765.
B-200
1
4 HP tube fitting. See section D for compatible meters.
**
MODELS HIGHLIGHTED!
DP41-E, DP25B-E, DP24-E DP41-E, DP25B-E, DP24-E DP41-E, DP25B-E, DP24-E DP41-E, DP25B-E, DP24-E DP41-E, DP25B-E, DP24-E
DP41-E, DP25B-E, DP24-E DP41-E, DP25B-E, DP24-E DP41-E, DP25B-E, DP24-E DP41-E, DP25B-E, DP24-E DP41-E, DP25B-E, DP24-E DP41-E, DP25B-E, DP24-E DP41-E, DP25B-E, DP24-E DP41-E, DP25B-E, DP24-E DP41-E, DP25B-E, DP24-E DP41-E, DP25B-E, DP24-E DP41-E, DP25B-E, DP24-E DP41-E, DP25B-E, DP24-E DP41-E, DP25B-E, DP24-E DP41-E, DP25B-E, DP24-E DP41-E, DP25B-E, DP24-E DP41-E, DP25B-E, DP24-E DP41-E, DP25B-E, DP24-E DP41-E, DP25B-E*, DP24-E* DP41-E, DP25B-E*, DP24-E*
PRESSURE TRANSDUCERS
CURRENT OUTPUT
B
AMPLIFIER HOUSING
(TOP COVER REMOVED)
0-10,000 PSI: 7/16-20
0-10,000 THRU 0-30,000 PSI: 9/16-18
70
(2.75)
235 (9.25)
MAX
92
(3.63)
1/2
19 (3/4)
HEX
38 (1.5) DIA.
1
6
(0.63)
1.50 DIA.
0.750 HEX
LIGHTNING-PROTECTED AMPLIFIER HOUSING
SPECIFICATIONS
xcitation: 12 to 40 Vdc
E Output: 4 to 20 mA ±10% adj Zero Balance: 4 mA +10% -2% adj Agency Approvals: FM Intrinsically
Safe IS/I.II.III/1/CDEFG standard
Linearity: ±0.15% FS Hysteresis: ±0.1% FS Repeatability: ±0.05% FS Sensing Element: 4-active-arm bridge,
using thick-film strain gages in a hermetically sealed chamber
Operating Temp Range:
-46 to 121°C (-50 to 250°F)
Compensated Temp Range:
16 to 71°C (60 to 160°F)
Thermal Effects:
Span: 0.005% of rdg/°F Zero: 0.005% of FS/°F
Proof Pressure:
150% of rated pressure
Burst Pressure:
300% of rated pressure
Wetted Parts: 17-4 PH SS
Pressure Port: Ranges <10000 psi:
7
16-20 UNF female, 1⁄4-18 NPT M/F or
7
16-20 UNF-2A male. 10K psi: 9⁄16-18,
1
4" HP tube.
Electrical Connection: Lightning­protected, explosion-proof amplifier box
CUSTOM CONFIGURATIONS
PX02 PRESSURE ELECTRICAL RANGE SERIES PORT CONNECTION (psi) UNITS OUTPUT OPTIONS
Models <10,000 psi
1
C =
4-18 NPT-M +$20
D = 1⁄4-18 NPT-F, no charge J = 7⁄16-20 UNF-M +$20 K = 7⁄16-20 UNF-F, no charge
Models 10,000 psi
S = 1⁄4 HP tube fitting
no charge
See page B-12 for additional options, including extended temperature ranges.
Ordering Examples: PX02C5-100GI, 100 psi gage pressure transducer with 4 to 20 mA output, $475 + 175 + 20 = $670.
PX02K5-1KSI, 1000 psi sealed gage pressure transducer, with output, $475 + 175 = $650.
PX02J5-015AI, 15 psi absolute pressure transducer with, $540 + 20 + 175 + 50 = $785.
PX02K5-025GI, 25 psi gage pressure transducer with $540 + 175 = $715.
[ 1 ] [ 2 ] [ 3 ] [ 4 ] [ 5 ] [ 6 ]
Base Price PX02 $650: 50 to 7500 psi $765: less than 50 psi $750: over 7500 psi
Add $50 for absolute pressure ranges I = 4 to 20 mA output
2 and 5 psi ranges available only on amplified output.
*
Supplied with
Metric ranges available–PXM02 Series, pages B-198 to B-199
To order a custom configuration:
1. Select a pressure port
2. Select electrical connection
3. Select a pressure range
4. Select pressure units
5. Select output
6. Select options and agency approvals
1
-18 NPT male fitting, lightning protected amplifier box and
4
0 = 3 m (10') cable (std)
+$2/.3 m (ft) over 3 m (10')
1 = PTIH-10-6P connector
(or equal, no charge). Mating connector (sold separately), order
PT06F10-6S, $26.50
5 = Lightning-protected
amplifier box (no charge) (4 to 20 mA models only)
002* 005* 010 015 020 025 050 075 100 150 200 250 300 500 750 1K
1.5K 2K 3K
3.5K 5K
7.5K 10K 20K 30K
7
16
7
-20 UNF female fitting, lightning protected amplifier box, 4 to 20 mA output,
16
S,G,A S,G,A S,G,A S,G,A S,G,A S,G,A S,G,A S,G,A S,G,A S,G,A S,G,A S,G,A S,G,A S,G,A S,G,A S,G,A S,G,A S,G,A S,G,A S,G,A S,G,A S,G,A
S,G,A
S,G,A
S,G,A
7
-20 UNF female fitting, lightning protected amplifier box and 4 to 20 mA
16
-20 UNF male fitting, lightning protected amplifier box and 4 to 20 mA output,
B-201
Dimensions: mm (in)
1
4 HP tube fitting.
OL = Overload stops
+$65
OX = Cleaned for
oxygen use +$75 plus 2 weeks
Loading...