HIGH-ACCURACY MILLIVOLT
38
(1.5)
DIA.
PTIH-10-6P
OR EQUAL
11
(0.45)
70 MAX
(2.75)
16
(0.625)
22
(0.875)
PX02:
19 HEX
(0.75)
PXM02: G1/4
Internal TH'D
PXM02:
21 HEX
(0.83)
PXM02:
21 HEX
(0.83)
38
(1.50)
DIA.
PX02:
19 HEX
(0.75)
0 to 10,000 psi: 7/16-20 UNF or 1/4 NPT
PX02: 10,000 psi and higher 1/4 HP tube
PXM02:
21 HEX
ELECTRICAL CONNECT OR:
PTIH-10-6P OR EQUAL
21
(0.81)
70
(2.75)
11
(0.45)
19 HEX
(0.75)
Male Connection
PX02
PXM02
18 HEX
(0.71)
OUTPUT PRESSURE TRANSDUCER
STANDARD AND METRIC MODELS
PX02/PXM02 Series
mV/V Output
0-10 to 0-30,000 psi-
Standard Models
0-700 mbar to 0-400 bar-
Metric Models
1 bar = 14.5 psi
1 kg/cm2= 14.22 psi
1 atmosphere = 14.7 psi = 29.93
inHg = 760.2 mmHg = 1.014 bar
S
⻬ FM Approved
Intrinsically Safe
⻬ FM Hazardous Location
Approval Optional
⻬ High Operating Temp:
163°C (325°F)
⻬ All Stainless Steel
Construction
⻬ Shunt Calibration for
⻬ Hermetically Sealed for
OMEGA’s PX02/PXM02 is a highaccuracy, 30-millivolt output
industrial pressure transducers. The
all stainless steel construction and
hermetically sealed case make them
suitable for harsh environments. An
FM Approved Intrinsically Safe
rating is standard, and hazardous
location ratings are optional. The
PX02/PXM02 have a high operating
range, a broad compensated range,
and excellent temperature
compensation that gives stable
readings in harsh applications. They
are available in gage, sealed, or
absolute models as well as psi or
metric ranges, with either connector
or cable terminations.
Fast System Setup
Harsh Environments
(Not Gage Units)
tandard
Starts at
$
475
A
n
i
C
PX02K1-100GV, 7⁄16-20 UNF
connection, $475, shown
STANDARD
actual size.
r
o
e
l
b
a
C
o
r
o
t
c
e
n
n
s
e
yl
t
S
e
l
b
a
l
i
va
SPECIFICATIONS
mV/V OUTPUT
Excitation: 10 Vdc (15 Vdc max)
Output: 3 mV/V ±0.25%
Input Resistance: 350 ±10 Ω
Output Resistance: 350 ±10 Ω
Linearity: ±0.15% FS
Hysteresis: ±0.1% FS
Repeatability: ±0.1% FS
Zero Balance: 1.0% FS
Agency Approvals:
Standard: FM Intrinsically Safe
IS/I.II.III/1/CDEFG
Optional: FM Hazardous Location
S/I/1/ABCD
Shunt Calibration: Value specified
on calibration sheet
Sensing Element: 4-active-arm bridge,
using thick-film strain gages in a
hermetically sealed chamber
Operating Temp Range:
-73 to 163°C (-100 to 325°F)
Compensated Temp Range:
16 to 71°C (60 to 160°F)
Female Connection
Wiring Code:
DIN Pin Wire Conn
2 A: GN + Out
3 B: WT - Out
GND C: BK - Ex
1 D: RD +Ex
E: BU Shunt
F: OR Shunt
B-59
METRIC
PXM01MC1-006BARGV, G
$495, shown actual size.
Thermal Effects:
Span: 0.003% rdg/°F
Zero: 0.003% FS/°F
Proof Pressure: 150% of rated pressure
Burst Pressure: 300% of rated pressure
Wetted Parts: 17-4 PH SS
Pressure Port: See custom
configurations chart
Electrical Connection: See custom
configurations chart
Mating Connector (Style 1):
PT06F10-6S (sold separately)
Weight: 255 g (9 oz)
Dimensions: mm (in)
1
⁄4,
Cable
style.
PX02C0-100GV, 1⁄4 NPT
male, $495, shown
smaller than actual size.
STANDARD CUSTOM CONFIGURATIONS
PX02 PRESSURE ELECTRICAL RANGE
SERIES PORT CONNECTION (psi) UNITS OUTPUT OPTIONS
Models < 10,000 psi
1
⁄4-18 NPT-M +$20
C =
D = 1⁄4-18 NPT-F, no charge
J = 7⁄16-20 UNF-M +$20
K = 7⁄16-20 UNF-F, no charge
Models ≥10,000 psi
S = 1⁄4 HP tube fitting
no charge
* 2 and 5 psi ranges available only with amplified output.
See page B-12 for additional options, including
extended temperature ranges.
Ordering Examples: PX02C1-100GI, 100 psi gage pressure transducer with
output, $475 + 20 + 175 = $670. PT06F10-6S, mating connector (sold separately), $26.50.
PX02K0-1KS5Z, 1000 psi sealed gage pressure transducer with
+ 190 = $665.
PX02J1-015A5T, 15 psi absolute pressure transducer with
$540 + 20 + 155 + 50 = $765. PT06F10-6S, mating connector (sold separately), $26.50.
[ 1 ] [ 2 ] [ 3 ] [ 4 ] [ 5 ] [ 6 ]
L = Overload stops
O
here available
w
$65
+
X = Oxygen cleaning
O
$75 plus 2 weeks
+
FM = FM hazardous
location
+$150
Mating
Connector
PT06F10-6S
$26.50
0 = 3 m (10') cable (std)
1 = PTIH-10-6P connector
(or equal, no charge).
Mating connector
(sold separately), order
PT06F10-6S $26.50
6 = mini DIN connector*
*no shunt cal (no charge)
G1⁄4 Pressure
Snubbers: $12.75
PS-4G-MG = Gas
PS-4E-MG = Lt Oil
PS-4D-MG = Dense
002*
005*
010
015
020
025
050
075
100
150
200
250
300
500
750
1K
1.5K
2K
3K
3.5K
5K
7.5K
10K
20K
30K
7
⁄
16
A,G,S
A,G,S
A,G,S
A,G,S
A,G,S
A,G,S
A,G,S
A,G,S
A,G,S
A,G,S
A,G,S
A,G,S
A,G,S
A,G,S
A,G,S
A,G,S
A,G,S
A,G,S
A,G,S
A,G,S
A,G,S
A,G,S
A,G,S
A,G,S
A,G,S
7
-20 UNF female fitting, 3 m (10') cable, and isolated 0 to 5 Vdc output, $475
⁄
16
-20 UNF male fitting, PTIH-10-6P connector and 0 to 5 Vdc output,
Base Price PX02:
V = mV/V output
$475: 50 to 7500 psig
$540: below 50 psig,
above 7500 psig
Add $50 for absolute
pressure ranges
To order a custom configuration:
1. Select a pressure port
2. Select electrical connection
3. Select a pressure range
4. Select pressure units
5. Select output
6. Select options and agency approvals
1
-18 NPT male fitting, PTIH-10-6P connector and 4 to 20 mA
⁄
4
Liquid
PRESSURE TRANSDUCERS
MILLIVOLT OUTPUT
B
METRIC CUSTOM CONFIGURATIONS
PXM01 PRESSURE ELECTRICAL RANGE
SERIES PORT CONNECTION (BAR) UNITS OUTPUT OPTIONS
[ 1 ] [ 2 ] [ 3 ] [ 4 ] [ 5 ] [ 6 ]
MA = G1⁄8B Male +$20
MB = G1⁄8B Female no charge
MC = G1⁄4B Male +$20
MD = G1⁄4B Female no charge
1.0
1.6
2.5
4.0
6.0
10
0 = 3 m (10') cable (std)
$15/m over 3 m (10')
1 = PTIH-10-6P connector
(or equal, no charge)
6 = mini DIN connector*
*no shunt cal (no charge)
See page B-12 for additional options including
16
25
40
60
100
160
250
400
extended compensated temperatures.
Ordering Examples: PXM01MB0-010BARSV, 10 bar sealed gage pressure transducer with G
termination, $475.
PXM01MD1-010BARAV, 10 bar absolute pressure transducer with G1⁄4B female connection and twist-lock connector, $525.
PT06F10-6S, mating connector (sold separately), $26.50.
A, G, S
A, G, S
A, G, S
A, G, S
A, G, S
A, G, S
A, G, S
A, G, S
A, G, S
A, G, S
A, G, S
A, G, S
A, G, S
A, G, S
V = mV/V Base price PXM01
$475 ≥2.5 bar
$540 <2.5 bar
Add $50 for absolute
pressure ranges
To order a custom configuration:
1. Select a pressure port
2. Select electrical connection
3. Select a pressure range
4. Select pressure units – absolute, gage
or sealed gage
5. Select output
6. Select options and agency approvals
1
B female connection and 3 m (10') cable
⁄
8
OX = Cleaned for
oxygen service
OL = Overload stops
( )m = Optional cable length
in meters
B-60