Omega Products PX02C1-010GV User Manual

HIGH-ACCURACY MILLIVOLT
38
(1.5)
DIA.
PTIH-10-6P
OR EQUAL
11
(0.45)
70 MAX
(2.75)
16
(0.625)
22
(0.875)
PX02:
19 HEX
(0.75)
PXM02: G1/4 Internal TH'D
PXM02: 21 HEX
(0.83)
PXM02: 21 HEX
(0.83)
38
(1.50)
DIA.
PX02:
19 HEX
(0.75)
0 to 10,000 psi: 7/16-20 UNF or 1/4 NPT
PX02: 10,000 psi and higher 1/4 HP tube
PXM02: 21 HEX
ELECTRICAL CONNECT OR: PTIH-10-6P OR EQUAL
21
(0.81)
70
(2.75)
11
(0.45)
19 HEX
(0.75)
Male Connection
PX02
PXM02 18 HEX (0.71)
F
M
A
PPROVED
OUTPUT PRESSURE TRANSDUCER
STANDARD AND METRIC MODELS
PX02/PXM02 Series
mV/V Output 0-10 to 0-30,000 psi-
Standard Models 0-700 mbar to 0-400 bar-
Metric Models
1 bar = 14.5 psi 1 kg/cm2= 14.22 psi 1 atmosphere = 14.7 psi = 29.93
inHg = 760.2 mmHg = 1.014 bar
S
FM Approved
Intrinsically Safe
FM Hazardous Location
Approval Optional
High Operating Temp:
163°C (325°F)
All Stainless Steel
Shunt Calibration for
Hermetically Sealed for
OMEGA’s PX02/PXM02 is a high­accuracy, 30-millivolt output industrial pressure transducers. The all stainless steel construction and hermetically sealed case make them suitable for harsh environments. An FM Approved Intrinsically Safe rating is standard, and hazardous location ratings are optional. The PX02/PXM02 have a high operating range, a broad compensated range, and excellent temperature compensation that gives stable readings in harsh applications. They are available in gage, sealed, or absolute models as well as psi or metric ranges, with either connector or cable terminations.
Fast System Setup
Harsh Environments (Not Gage Units)
tandard
Starts at
$
475
A
n
i
C
PX02K1-100GV, 7⁄16-20 UNF
connection, $475, shown
STANDARD
actual size.
r
o
e
l
b
a
C
o
r
o
t
c
e
n
n
s
e
yl
t
S
e
l
b
a
l
i
va
SPECIFICATIONS
mV/V OUTPUT
Excitation: 10 Vdc (15 Vdc max) Output: 3 mV/V ±0.25% Input Resistance: 350 ±10 Output Resistance: 350 ±10 Linearity: ±0.15% FS Hysteresis: ±0.1% FS Repeatability: ±0.1% FS Zero Balance: 1.0% FS Agency Approvals:
Standard: FM Intrinsically Safe
IS/I.II.III/1/CDEFG Optional: FM Hazardous Location S/I/1/ABCD
Shunt Calibration: Value specified on calibration sheet
Sensing Element: 4-active-arm bridge, using thick-film strain gages in a hermetically sealed chamber
Operating Temp Range:
-73 to 163°C (-100 to 325°F)
Compensated Temp Range:
16 to 71°C (60 to 160°F)
Female Connection
Wiring Code: DIN Pin Wire Conn 2 A: GN + Out 3 B: WT - Out GND C: BK - Ex 1 D: RD +Ex
E: BU Shunt F: OR Shunt
B-59
METRIC
PXM01MC1-006BARGV, G $495, shown actual size.
Thermal Effects:
Span: 0.003% rdg/°F
Zero: 0.003% FS/°F Proof Pressure: 150% of rated pressure Burst Pressure: 300% of rated pressure Wetted Parts: 17-4 PH SS Pressure Port: See custom
configurations chart Electrical Connection: See custom
configurations chart
Mating Connector (Style 1):
PT06F10-6S (sold separately)
Weight: 255 g (9 oz)
Dimensions: mm (in)
1
4,
Cable style.
PX02C0-100GV, 1⁄4 NPT male, $495, shown smaller than actual size.
STANDARD CUSTOM CONFIGURATIONS
PX02 PRESSURE ELECTRICAL RANGE SERIES PORT CONNECTION (psi) UNITS OUTPUT OPTIONS
Models < 10,000 psi
1
4-18 NPT-M +$20
C = D = 1⁄4-18 NPT-F, no charge J = 7⁄16-20 UNF-M +$20 K = 7⁄16-20 UNF-F, no charge
Models 10,000 psi
S = 1⁄4 HP tube fitting
no charge
* 2 and 5 psi ranges available only with amplified output.
See page B-12 for additional options, including extended temperature ranges.
Ordering Examples: PX02C1-100GI, 100 psi gage pressure transducer with output, $475 + 20 + 175 = $670. PT06F10-6S, mating connector (sold separately), $26.50.
PX02K0-1KS5Z, 1000 psi sealed gage pressure transducer with + 190 = $665.
PX02J1-015A5T, 15 psi absolute pressure transducer with $540 + 20 + 155 + 50 = $765. PT06F10-6S, mating connector (sold separately), $26.50.
[ 1 ] [ 2 ] [ 3 ] [ 4 ] [ 5 ] [ 6 ]
L = Overload stops
O
here available
w
$65
+
X = Oxygen cleaning
O
$75 plus 2 weeks
+
FM = FM hazardous
location
+$150
Mating Connector
PT06F10-6S $26.50
0 = 3 m (10') cable (std) 1 = PTIH-10-6P connector
(or equal, no charge). Mating connector (sold separately), order
PT06F10-6S $26.50
6 = mini DIN connector*
*no shunt cal (no charge)
G1⁄4 Pressure Snubbers: $12.75
PS-4G-MG = Gas PS-4E-MG = Lt Oil PS-4D-MG = Dense
002* 005* 010 015 020 025 050 075 100 150 200 250 300 500 750 1K
1.5K 2K 3K
3.5K 5K
7.5K 10K 20K 30K
7
16
A,G,S A,G,S A,G,S A,G,S A,G,S A,G,S A,G,S A,G,S A,G,S A,G,S A,G,S A,G,S A,G,S A,G,S A,G,S A,G,S A,G,S A,G,S A,G,S A,G,S A,G,S A,G,S A,G,S A,G,S A,G,S
7
-20 UNF female fitting, 3 m (10') cable, and isolated 0 to 5 Vdc output, $475
16
-20 UNF male fitting, PTIH-10-6P connector and 0 to 5 Vdc output,
Base Price PX02: V = mV/V output $475: 50 to 7500 psig $540: below 50 psig,
above 7500 psig
Add $50 for absolute pressure ranges
To order a custom configuration:
1. Select a pressure port
2. Select electrical connection
3. Select a pressure range
4. Select pressure units
5. Select output
6. Select options and agency approvals
1
-18 NPT male fitting, PTIH-10-6P connector and 4 to 20 mA
4
Liquid
PRESSURE TRANSDUCERS
MILLIVOLT OUTPUT
B
METRIC CUSTOM CONFIGURATIONS
PXM01 PRESSURE ELECTRICAL RANGE SERIES PORT CONNECTION (BAR) UNITS OUTPUT OPTIONS
[ 1 ] [ 2 ] [ 3 ] [ 4 ] [ 5 ] [ 6 ]
MA = G1⁄8B Male +$20 MB = G1⁄8B Female no charge MC = G1⁄4B Male +$20 MD = G1⁄4B Female no charge
1.0
1.6
2.5
4.0
6.0 10
0 = 3 m (10') cable (std)
$15/m over 3 m (10')
1 = PTIH-10-6P connector
(or equal, no charge)
6 = mini DIN connector*
*no shunt cal (no charge)
See page B-12 for additional options including
16 25 40 60 100 160 250 400
extended compensated temperatures.
Ordering Examples: PXM01MB0-010BARSV, 10 bar sealed gage pressure transducer with G termination, $475.
PXM01MD1-010BARAV, 10 bar absolute pressure transducer with G1⁄4B female connection and twist-lock connector, $525. PT06F10-6S, mating connector (sold separately), $26.50.
A, G, S A, G, S A, G, S A, G, S A, G, S A, G, S A, G, S A, G, S A, G, S A, G, S A, G, S A, G, S A, G, S A, G, S
V = mV/V Base price PXM01 $475 2.5 bar $540 <2.5 bar
Add $50 for absolute pressure ranges
To order a custom configuration:
1. Select a pressure port
2. Select electrical connection
3. Select a pressure range
4. Select pressure units – absolute, gage
or sealed gage
5. Select output
6. Select options and agency approvals
1
B female connection and 3 m (10') cable
8
OX = Cleaned for
oxygen service
OL = Overload stops
( )m = Optional cable length
in meters
B-60