LOW-COST, ELECTRONICALLY
10.1
(0.396)
5.0
(0.198)
15.0 (0.59)
7.5 (0.295)
#8-32 NC-2B TH'D 2 PLC'S
DIMENSIONS mm (inches)
CONTROLLED PROPORTIONAL VALVES
USING SOLENOID TECHNOLOGY
PV100 Series
U Low Power Consumption U 100 ms Response Time
at Maximum Pressure
U Stainless Steel Wetted
U 12 to 24 Vdc Power U For Clean, Dry, Non-
Corrosive Gases Only
The OMEGA® PV100 Series comprises economical proportional valves for use with gases. They combine a solenoid valve with an electronics package that digitally modulates the control signal to provide analog proportional control without the expense or complexity of stepper motors, servo valves, or other proportioning devices. The PV100 Series can be used in open­or closed-loop systems to control flow, pressure, temperature, speed, or position parameters of gases.
SPECIFICATIONS
Valve Type: 2-way normally closed Wetted Parts: Stainless steel with
FKM seals
Power: 12 to 24 Vdc Power Consumption: 7 W maximum Control Signals: 0 to 5 Vdc, 0 to 10
Vdc or 4 to 20 mA DC (specify when ordering)
Ambient Temperature Range:
-10 to 50°C (14 to 122°F) media temperature
Range: -18 to 82°C (0 to 180°F) Linear Control Range: 15 to 85% of
full flow
Response Time for Complete Cycle (Off—Fully Open—Off): 40 ms
@ 0 pressure; 100 ms @ max pressure
PV101-MA with CNi16D53 controller (sold separately), shown actual size. Visit omega.com
Dimensions: mm (inch)
84.07 (3.31)
Repeatability: ±5% when in operating linear control range
Electrical Connection: 0.4 m (18") color-coded lead wires
Wiring: Red: DC power supply
74.45 (3.01)
P
13.46 (0.53)
Gray: Control signal (+) Black: Common (to power and control)
Pressure Connections:
1
8 FNPT
32.51 (1.28)
Enclosure: General purpose, NEMA 11
50.80 (2.00)
To Order
MODEL NO. ORIFICE C
PV101-(*) PV102-(*) PV103-(*) PV104-(*)
(*) Specify input control signal: “-MA” for 4 to 20 mA DC, “-5V” for 0 to 5 Vdc and “-10V” for 0 to 10 Vdc.
Comes complete with operator’s manual. Ordering Example: PV103-MA, proportional valve with
pressure and 4 to 20 mA DC input control signal.
Visit omega.com/pv100 for Pricing and Details
FLOW RANGES, SCCM
MAXIMUM PRESS. PRESS. (10 psi)
V
1
32
"
3
64
"
1
16
"
5
64
"
0.02 13.8 bar (200 psi) 0 to 50,000 0 to 8000
0.045 7 bar (100 psi) 0 to 65,000 0 to 17,000
0.08 4 bar (60 psi) 0 to 75,000 0 to 30,000
0.12 2.7 bar (40 psi) 0 to 80,000 0 to 45,000
AT MAXIMUM
1
" orifice, 4 bar (60 psi) maximum
16
26.92 DIA. (1.06 DIA.)
1/8 NPT 2 PLC'S
AT 0.7 bar
L-21