Omega Products PTC900-GN-LV User Manual

M-127
1
8 DIN Panel-Mount
Programmable Timer
The PTC900 timer and PTC901 clock/timer offer many features and performance capabilities that suit a wide range of industrial applications. Both can function as an elapsed timer or preset timer, while the PTC901 also offers real-time clock with date capability. The plug-in option cards allow the user to configure the meter for the present application, while providing easy upgrades for future needs. Both models can function as an elapsed­time indicator. By using 2 separate signal inputs and 23 selectable timer ranges, the meters can be programmed to meet most any timing application. With the addition of a plug-in setpoint output card, they can easily become a dual or quad output preset timer. The PTC901 can also operate as a real­time clock with the real-time clock card already installed.
PTC900/PTC901 Series
Starts at
$
169
⻬1⁄8 DIN (50 x 97 mm) 6-Digit, 14.2 mm (0.56")
LED Display
Green Display or Red,
Sunlight-Readable Display
Elapsed Timer with
Preset Capability
Counter with
Preset Capability
Cycle Counting
Capability
Programmable Function
Keys and User Inputs
4 Setpoint
Alarm Outputs
Communications and
Bus Capabilities
PC Software Available
for Meter Configuration
NEMA 4X (IP65)
The meters are capable of displaying time in 12- or 24-hour time formats. The 12-hour format can be displayed in hours and minutes, with or without an am/pm indication or in hours, minutes, and seconds. The 24-hour format can be displayed in hours and minutes or in hours, minutes, and seconds.
The PTC901 also has a calendar display in which the day, month and/or year can be displayed. The meter will recognize leap years, and can automatically adjust for Daylight Savings time. If the application calls simultaneously for a preset timer and a real-time clock, the PTC901 can handle this requirement as well. A battery-backed real-time clock plug-in card is provided with the PTC901. This card, which includes a lithium coin-cell battery, will maintain the time and date when main power is removed.
The meters accept inputs from a variety of sources, including switch contacts and outputs from CMOS or TTL circuits. The input can be configured to trigger on the edge or level of the incoming pulse. Internal jumpers are available for selecting sinking inputs (active-low) or
sourcing inputs (active-high). The front panel keys and three user inputs are programmable to perform various meter functions. The meters can have up to 4 setpoint outputs, determined by the optional plug-in cards. The setpoint plug-in cards provide dual form “C” relays (5A), quad form “A” relays (3A) or either quad-sinking or quad-sourcing open collector logic outputs. The outputs can be assigned to the timer, counter, RTC date, and RTC time. The outputs can also be independently configured to suit a variety of control and alarm requirements.
Plug-in cards can also provide serial communications. These include RS232, RS485 and MODBUS
®
. Display values, setpoint alarm values and setpoint states can be controlled through serial communications. Once the meters have been initially configured, the parameter list may be locked out from further modification entirely, or the setpoint, timer start/stop values, counter start/stop values, RTC time “set”, and display intensity can be made accessible. Lockouts are activated through a security code or user input.
PTC901, $211, shown smaller than actual size.
PTC901 case and mechanics, shown smaller than actual size.
Panel punches
available, visit
omega.com/
panelpunches
M-128
M
Specifications
Display: 6-digit, 14.2 mm (0.56") red
sunlight-readable or standard green LED
Power:
AC Versions:
AC Power: 85 to 250 Vac,
50/60 Hz, 18 VA Isolation: 2300 Vrms for 1 min to
all inputs and outputs; 300V working
DC Versions:
DC Power: 11 to 36 Vdc, 14 W
(derate operating temperature to 40°C (104°F) if operating <15 Vdc and 3 plug-in cards are installed)
AC Power: 24 Vac, ± 10%, 50/60 Hz, 15 VA
Isolation: 500 Vrms for 1 min to all inputs and outputs (50V working)
Sensor Power: 12 Vdc, ±10%, 100 mA max; short circuit protected
Keypad: 3 programmable function keys, 5 keys total
Timer Display
Timer Range: 23 selectable ranges Timing Accuracy: ± 0.01% Minimum Digit Resolution: 0.001 s Maximum Least Significant Digit
Resolution: 1 hr Maximum Display: 999999
Current Sinking (Active-Low): V
il
=
0.9 V max, 22 KW pull-up to 12 Vdc Current-Sourcing (Active-High): V
ih
=
3.6 V min, 22 KW pull-down, max
Continuous Input: 30 Vdc Timer Input Pulse Width: 1 ms minimum Timer Start/Stop Response Time:
1 ms max Filter: Software filtering provided for
switch contact debounce; filter enabled or disabled through programming; if enabled, filter results in 50 ms start/stop response time for successive pulses on the same input terminal
User Inputs
Type: 3 programmable user inputs; logic
inputs configurable as current-sinking (active-low) or current-sourcing (active­high) through a single plug jumper
Current Sinking (Active-Low):
V
il
= 0.9V max, 22 KΩ pull-up to 12 Vdc
Current-Sourcing (Active-High):
V
ih
= 3.6V min, 22 KΩ pull-down, max
Continuous Input: 30 Vdc Isolation To Timer Input Common:
Not isolated
Response Time: 10 ms Memory: Non-volatile E
2
PROM retains all programming parameters and display values
Cycle Counter Display:
Counter Range: 0 to 999999 Digit Resolution: 1 cycle Maximum Count Rate: 50 Hz
Real-Time/Date Display (PTC901):
Real-Time Display: 5 display formats—
hr/min/second (12 or 24 hr format), hr/min (24 hr), hr/min (12 hr with or without AM/PM indication)
Date Display: 7 display formats— month/day or day/month (numeric or 3-letter month format), month/day/year or day/month/year (all numeric), day of week/day (3-letter day of week format)
Real-Time Clock Card:
Field-replaceable plug-in card Time Accuracy: ± 5 s/month (1 min/year)
with end-user calibration
Battery: Lithium 2025 coin cell Battery Life Expectancy: 10 years, typical Synchronization Interface: 2-wire
multi-drop network (RS485 hardware), 32 units max, operates up to 4000'
Isolation To Timer and User Input Commons: 500 Vrms for 1 min
Working Voltage: 50V, not isolated
from all other commons.
Timer Inputs A and B
Type: Logic inputs configurable as current-
sinking (active-low) or curren-sourcing (active-high) via a single plug jumper
Dimensions: mm (in)
96.5
(3.80)
49.5
(1.95)
2.5
(0.10)
104.1 (4.10)
44.5
(1.75)
91.4
(3.60)
44.5
(1.75)