OMEGAnet@
www.omega.com
On-Line Service Internet e-mail
info@omega.com
Servicing North America:
USA:
IS0
9001 Certified
Canada:
For immediate technical or application assistance:
USA and Canada:
Mexico:
Benelux:
Czech Republic:
France:
Germany/Austria:
United Kingdom:
IS0
9002
Ce M
..
One Omega Drive, Box 4047
Stamford CT 06907-0047
Tel: (203) 359-1660
e-mail:
976 Bergar
Lava1 (Quebec)
Tel: (514) 856-6928
e-mail: info @ omega.ca
Sales
Customer Service: l-800-622-2378
Engineering Service: l-800-872-9436
TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA
Tel: (001) 800-826-6342
En
info @omega.com
H7L
5Al
Service: l-800-826-6342
Espanol: (001) 203-359-7803
l-800-TC-OMEGA@
/
FAX: (203) 359-7700
FAX: (514) 856-6886
l-800-622-BEST ’
/
l-800-USA-WHEN ”
/
FAX: (001) 203-359-7807
e-mail:
Servicing Europe:
Postbus 8034, 1180 LA Amstelveen, The Netherlands
+3120 6418405
Tel:
Toll Free in Benelux: 0800 0993344
e-mail:
Rude
Tel:
Toll Free: 0800-l-66342
9, rue
Tel:
Toll Free in France: 0800-4-06342
e-mail:
Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
Tel: t-49 (07056) 3017
Toll Free in Germany: 0800
e-mail:
One Omega Drive, River Bend Technology Centre
Northbank, Irlam, Manchester
M44 5EX United Kingdom
Tel:
Toll Free in United Kingdom:
e-mail:
nl@omega.com
armady
+420
Denis
+33
+44
1868,733 01
(69) 6311899
Papin, 78190 Trappes
130-621-400
france @omega.com
germany @omega.com
(0)161
777 6611
sales @omega.co.uk
Karvina
TC-OMEGASM
0800-488-488
FAX:
8
FAX:
e-mail:
FAX:
FAX:
FAX:
espanol @omega.com
info @omega.com.mx
+3120 6434643
+420
(69) 6311114
czech @omega.com
+33
130-699-120
+49
(07056) 8540
(0)161777 6622
+44
It
is
the policy of OMEGA to comply with all worldwide safety and
apply. OMEGA is constantly pursuing certification of its products to the European New Approach
Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct, but OMEGA Engineering, Inc. accepts
no liability for any errors it contains, and reserves the right to alter specifications without notice.
WARNING: These products are not designed for use in, and should not be used for, patient-connected applications.
EMC/EMI
regulations that
OVERVIE W
8mm
46mm
3
I_-
66mm
61mm
To wire the unit, an 11 pin socket is required. The
unit can either be DIN rail mounted or panel
mounted using the supplied mounting bracket.
For panel mounting, place the unit in the cutout.
then slide the bracket forward over the rear of the
unit so that the tabs catch in the grooves on the
housing and the bracket is as far forward as
possible. Tighten the panel mount screws until
there is a snug fit against the panel. Do not
overtighten.
Warning: Do Not connect a coil in parallel
with the start signal. Such a connection
will cause the start signal to be continu-
ously active. This situation also applies to
the Reset input.
1