Omega Products PSW601B Installation Manual

PSW601B TERMINAL BLOCK
PSW601B CIRCUIT LAYOUT
POWER + POWER –
NC
C
NO
M3422 8/99 DPS-5C-1P-10/99 Printed in U.S.A.
®
PSW601B
N-Series
INSTRUCTION
SHEET
M3422/1002
INSTALLATION AND MAINTENANCE PSW601B SERIES
OMEGA®ELECTRONIC SWITCHES FOR PRESSURE CONTROL
INTRODUCTION
The Omega pressure switch is a pre­cision built control device which fea­tures a polysilicon thin film pressure sensor (Transducer). Controllers are available for operation on pressure or vacuum with fixed or variable dif­ferential. The standard electrical switch is a SPDT sealed mechanical relay. The wetted materials are 17­4pH and 316 stainless steel.
The Omega pressure switch is fur­nished in the standard NEMA 4 enclosures which are epoxy coated aluminum castings.
INSTALLATION
These controls are precision instruments and should never be left with internal components exposed. After installation, ensure that the covers are in place and the conduit openings are closed.
MOUNTING PSW601B SERIES
There are three holes external to the enclosures for surface mounting. The location of these holes are shown on the general dimension drawing. The controls may also be mounted direct­ly on the pressure line using the pres­sure connection. When tightening the
control to the pressure line, always use the wrench flats or the hex on the lower housing.
ELECTRICAL CONNECTIONS
Remove cover
PSW601B Series – two screws hold
cover to enclosure.
CONDUIT CONNECTIONS
Note – It is recommended that Teflon tape or other sealant be used on the conduit, bushing or plug threads to ensure the integrity of the enclosure.
PSW601B Series Standard – one
1
2
NPT conduit hole right side.
PSW601B SERIES SPDT – Wire directly to the terminal
block according to circuit require­ments. For 120/250Vac 60Hz switch, wire power lines to terminals marked AC. For 24Vdc switch, wire positive power line to terminal marked 24Vdc+ and wire negative power line to terminal marked 24Vdc–.
Adjustment of Setpoint – A four turn
adjustment potentiometer is located at the upper right corner on the inside of the enclosure.
For accurate setpoint calibration, mount the switch on a calibration stand, a pump or catalog DWT-1305 deadweight gauge tester. A suitable reference standard such as an Omega Test Gauge is necessary to observe changes in pressure.
As received, the pressure switch will normally be set to approximately 90% of the indicated range. Pressurize the system to the required setpoint and turn the adjustment potentiometer until the switch changes mode. Clockwise rotation of the potentiome­ter will increase the setpoint and counter clockwise rotation of the potentiometer will decrease the set­point. When the setpoint has been achieved, raise and lower the pres­sure to ensure that the setpoint is cor­rect. The indicating LEDs will show red when the pressure is below the setpoint and green when the pressure is above the setpoint.
Adjustment of Deadband – A four turn adjustment potentiometer is located at the upper right corner on the inside of the enclosure just below the setpoint potentiometer.
The deadband is adjusted as above. Clockwise rotation of the potentiome­ter will increase the deadband and counter clockwise rotation of the poten­tiometer will decrease the deadband.
After installation of the control, replace the cover to ensure electrical safety and to protect the internal parts from the environment.
B
Ø 0.28 (3 Holes)
D
A
C
1/2 NPT Male & 1/4 NPT Female
3/4 NPT
F
1/4 NPT Female
H
A
I
G
E
PSW601B
ABCDEFGHI J
5431⁄4 35⁄16 23⁄4 25⁄16
13⁄16 23⁄4
23⁄16 23⁄4
(127) (102) (83) (84) (70) (59) (30) (70) (56) (70)
1.8 lb
(.81 kg)
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, patient connected applications.
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.
If the unit should malfunction, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of being damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components which wear are not warranted, including but not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes respon­sibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts man­ufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTA­TIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnifica­tion, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/ DISCLAIMER language, and additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
RETURN REQUESTS / INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.
FOR
WARRANTY RETURNS, please have the following
information available BEFORE contacting OMEGA:
1. P. O. number under which the product was PURCHASED,
2. Model and serial number of the product under warranty, and
3. Repair instructions and/or specific problems relative to the product.
FOR NON-W
ARRANTY
REPAIRS,
consult OMEGA for cur­rent repair charges. Have the following information avail­able BEFORE contacting OMEGA:
1. P. O. number to cover the COST of the repair,
2. Model and serial number of product, and
3. Repair instructions and/or specific problems relative to
the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technol­ogy and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC. © Copyright 1999 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to
any electronic medium or machine-readable form, in whole or in part, without prior written consent of OMEGA ENGINEERING, INC.
MADE IN
Servicing North America:
USA: One Omega Drive, P.O. Box 4047
ISO 9001 Certified Stamford CT 06907-0047
TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com
Canada: 976 Bergar
Laval (Quebec) H7L 5A1 TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: canada@omega.com
For immediate technical or application assistance:
USA and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA
®
Customer Service: 1-800-622-2378 / 1-800-622-BEST
®
Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN
®
TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA
Mexico: Tel: (001) 800-826-6342 FAX: (001) 203-359-7807
En Espan˜ol: (001) 203-359-7803 e-mail: espanol@omega.com
info@omega.com.mx
omega.com
OMEGAnet®On-Line Service Internet e-mail
www.omega.com info@omega.com
Servicing Europe:
Benelux: Postbus 8034, 1180 LAAmstelveen, The Netherlands
Tel: +31 (0)20 6418405 FAX: +31 (0)20 6434643 Toll Free in Benelux: 06 0993344 e-mail: nl@omega.com
Czech Republic: Rudé armády 1868,73301 Karviná
TEL: +420 (0)69 6311899 FAX: +420 (0)69 6311114 Toll Free in Czech Rep.: 0800-1-66342 e-mail: czech@omega.com
France: 9, rue Denis Papin, 78190 Trappes
TEL: +33 (0)130 621 400 FAX: +33 (0)130 699 120 Toll Free in France: 0800-4-06342 e-mail: france@omega.com
Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
TEL: +49 (0)7056 3017 FAX: +49 (0)7056 8540 Toll Free in Germany: 0800 TC OMEGA
SM
e-mail: germany@omega.com
United Kingdom: P.O. Box 7, Omega Drive,
ISO 9002 Certified Irlam, Manchester,
M44 5EX, United Kingdom TEL: +44 (0)161 777 6611 FAX: +44 (0)161 777 6622 Toll Free in England: 0800 488 488 e-mail: sales@omega.co.uk
TM
®
Loading...