Omega Products PRTXD-12-SL User Manual

0.75
(+)RED
Remote Device
Omega Engineering Made in USA
3.5
°F
Span
Zero
TEST
Test
3 ft long, 2-conductor 22 AWG cable
Loop Power
Supply
24 VDC typical
( – ) ( + )
( – )
( + )
0.75
2.0
0.25 dia.
Stem
length
“L”
1/2 NPT
316 SS
hex nipple
Continuous
weld on
non-spring
loaded
models
1.37
1.25
1400
1200
1000
800
600
400
200
0
) s m h O ( e c n a t s i s e R p o o L x a M
81216202428 32
Loop Supply Voltage (DC)
Voltage Compliance for
4-20 mA Current Loop
3.0
(–)BLACK
Spring-loaded
probes
0.25" nom.
compression
(0.50" max)
Typical
thermowell
Temperature Transmitter
With Display and RTD Sensor
PRTXD Series
U 2-Wire Transmitter U 4 to 20 mA Output U 41⁄2 Digit LCD U RTD Probe Included U NEMA 4X (IP66) Housing
The PRTXD Series are 2-wire transmitters that provide a 4 to 20 mA
signal representing temperature. The units include a 41⁄2 digit display and the RTD sensor. The NEMA 4X (IP66) housing protects the electronics. Units are available with spring-loaded probes for use with thermowells.
Specifications
Sensor: 100 W RTD element, 0.00385
alpha coefficient IEC-751 class B: ±0.3°C at 0°C, ±1.1°C at 150°C Display: 4 4 readings per second, nominal display update rate
Out of Range Indication: ALARM 1: On display above
200°C (392°F) ALARM 2: On display below
-50°C (-58°F) Loop Supply Voltage: Any DC supply/loop resistance that maintains 8 to 32 Vdc at gauge terminals (reverse polarity protected) Loop Output Characteristics: 4 to 20 mA output (see chart for loop voltage characteristics), minimum 8V required at gauge terminals at all times for proper operation Test Function: Front panel TEST button when held, sets loop current and display to test calibration level, independent of temperature input to allow testing of system operation
Wiring Connections (See Drawing): 0.9 m (3') long,
2-conductor 22 AWG cable Material and Color: NEMA 4X (IP66) ABS/Polycarbonate housing, light gray gasketed rear cover connection and probe material: 316 stainless steel probe sheath Operating Temperature (Electronics):
-20 to 85°C (-4 to 185°F) Storage Temperature:
-40 to 95°C (-40 to 203°F)
1
2 digit LCD, 1⁄2" digit height,
1
2 NPT male hex nipple,
Weight: Transmitter: Approx 340 g (12 oz) Shipping Weight: Approx 450 g (1 lb)
Range: -50 to 200°C (-58 to 392°F) Resolution: 0.1 degree Accuracy: ±0.1% of span plus max
sensor error of ±0.3°C at 0°C or ±1.1°C at 150°C
PRTXD-4 RTD transmitter with display and 4" sensor
PRTXD-4-SL RTD transmitter with display and 4" spring-loaded sensor
PRTXD-12 RTD transmitter with display and 12" sensor
PRTXD-12-SL RTD transmitter with display and 12" spring-loaded
Comes complete with operator’s manual. Thermowell required for spring-loaded versions, for 4 and 12" sensors.
Ordering Example: PRTXD-12, RTD transmitter with display and 12” sensor.
See omega.com
for Thermowells
To Order Visit omega.com/prtxd for Pricing and Details
Dimensions: inch
Model No. Description
N-10
PRTXD-4 shown smaller than actual size.
sensor
N
Loading...