0.75
(+)RED
Remote Device
Omega Engineering Made in USA
3.5
°F
Span
Zero
TEST
Test
3 ft long,
2-conductor
22 AWG
cable
Loop Power
Supply
24 VDC typical
( – ) ( + )
( – )
( + )
0.75
2.0
0.25 dia.
Stem
length
“L”
1/2 NPT
316 SS
hex nipple
Continuous
weld on
non-spring
loaded
models
1.37
1.25
1400
1200
1000
800
600
400
200
0
) s m h O ( e c n a t s i s e R p o o L x a M
81216202428 32
Loop Supply Voltage (DC)
Voltage Compliance for
4-20 mA Current Loop
3.0
(–)BLACK
Spring-loaded
probes
0.25" nom.
compression
(0.50" max)
Typical
thermowell
Temperature Transmitter
With Display and RTD Sensor
PRTXD Series
U 2-Wire Transmitter
U 4 to 20 mA Output
U 41⁄2 Digit LCD
U RTD Probe Included
U NEMA 4X (IP66) Housing
The PRTXD Series are 2-wire
transmitters that provide a 4 to
20 mA
signal representing
temperature. The units include a
41⁄2 digit display and the RTD sensor.
The NEMA 4X (IP66) housing
protects the electronics. Units are
available with spring-loaded probes
for use with thermowells.
Specifications
Sensor: 100 W RTD element, 0.00385
alpha coefficient IEC-751 class B:
±0.3°C at 0°C, ±1.1°C at 150°C
Display: 4
4 readings per second, nominal display
update rate
Out of Range Indication:
ALARM 1: On display above
200°C (392°F)
ALARM 2: On display below
-50°C (-58°F)
Loop Supply Voltage: Any DC
supply/loop resistance that maintains
8 to 32 Vdc at gauge terminals
(reverse polarity protected)
Loop Output Characteristics:
4 to 20 mA output (see chart for loop
voltage characteristics), minimum
8V required at gauge terminals at
all times for proper operation
Test Function: Front panel TEST button
when held, sets loop current and display
to test calibration level, independent
of temperature input to allow testing of
system operation
Wiring Connections
(See Drawing): 0.9 m (3') long,
2-conductor 22 AWG cable
Material and Color: NEMA 4X (IP66)
ABS/Polycarbonate housing, light gray
gasketed rear cover connection and
probe material:
316 stainless steel probe sheath
Operating Temperature (Electronics):
-20 to 85°C (-4 to 185°F)
Storage Temperature:
-40 to 95°C (-40 to 203°F)
1
⁄2 digit LCD, 1⁄2" digit height,
1
⁄2 NPT male hex nipple,
Weight:
Transmitter: Approx 340 g (12 oz)
Shipping Weight:
Approx 450 g (1 lb)
Range: -50 to 200°C (-58 to 392°F)
Resolution: 0.1 degree
Accuracy: ±0.1% of span plus max
sensor error of ±0.3°C at 0°C or
±1.1°C at 150°C
PRTXD-4 RTD transmitter with display and 4" sensor
PRTXD-4-SL RTD transmitter with display and 4" spring-loaded sensor
PRTXD-12 RTD transmitter with display and 12" sensor
PRTXD-12-SL RTD transmitter with display and 12" spring-loaded
Comes complete with operator’s manual.
† Thermowell required for spring-loaded versions, for 4 and 12" sensors.
Ordering Example: PRTXD-12, RTD transmitter with display and 12” sensor.
See omega.com
for Thermowells
To Order Visit omega.com/prtxd for Pricing and Details
Dimensions: inch
Model No. Description
N-10
PRTXD-4
shown smaller
than actual size.
sensor
N
†
†