ACCURACY
IEC CLASS
BB
(±0.30ºC @ 0ºC)
With Stainless Steel BX Armor Cable for
Industrial Applications
Standard Dimensions
⻬ Transitions Directly to Lead Wires
(No Transitions Fitting)
⻬ Compact Design for Applications
with Space Restrictions
⻬ Available in Standard and
Metric Sizes
Probe length specified by customer
Starts at
$
48
40" of #26 AWG stranded
nickel-plated copper, fiberglass
insulated, fiberglass jacketed
cable with SST BX armor
Note: BX armor is attached to
outside of sheath
PRTF-10-2-100-1/4-12-E-BX,
$48, shown smaller than
actual size.
⻬ Temperature Range: -50 to 500°C
Precision Thin Film 100 or 1000 Ω, Class B DIN Platinum
⻬
Elements per IEC60751 (alpha = 0.00385 Ω/Ω/°C)
⻬ 2-, 3-, 4-Wire Constructions Available
⻬ All Sensors Supplied to IEC60751/ASTM E-1137
Color Codes
300
Probe Length
(2" minimum)
PFA Coating
Available, See
Page C-92
(See ordering example)
Probe Diameters:
Standard =
6"
1
⁄4, 3⁄16, 1⁄8"
Stripped lead wires
standard. Optional
connectors available,
see section G.
Series
stainless
steel probe
100 Ω Sensor
To Order
Model Number
PRTF-10-2-100-(*)-6-E-BX
PRTF-10-2-100-(*)-12-E-BX 3 Wire
PRTF-10-2-100-(*)-18-E-BX 3 Wire
PRTF-10-2-100-(*)-24-E-BX 3 Wire
Specify “-1/8”, “-3/16”, or “-1/4” for probe diameter in inches. To order 4-wire sensors, change “-2” to “-3” in the model number and add $5
*
to the price. To order with shrink tube strain relief, specify “-ST” at end of model number, no additional charge. To order probes in intermediate
lengths (2" minimum), change length in model number and use next longer probe price. For probe lengths over 24", change length in model
number and add $1 per inch of probe length. Cable length refers to length of metal hose with cable extending 6" minimum from end of metal
hose. For metal hose lengths longer than 40", add length to end of model number and add $2.50 per foot. For MTP or OTP connectors, add “-
MTP” or “-OTP” to model number and $7.
Ordering Example:
OTP connector, $54 + 7 = $61.
(Specify Model Number)
Lead Wire Style Sheath Length
3 Wire
PRTF-10-2-100-1/8-12-E-BX-OTP, 100 Ω, Class “B” RTD with a
6"
12"
18"
24"
1
" diameter by 12" long probe, 40" of 3-wire cable with BX armor and
⁄8
MOST POPULAR MODELS HIGHLIGHTED!
1
" Dia.
⁄4
$48
48
54
57
3
16
⁄
$54
Price
" Dia.
54
61
64
1
" Dia.
8
⁄
$54
54
61
64
1000 Ω Sensor
To Order
Model Number Lead Wire Style Sheath Length
PRTF-10-2-1000-(*)-6-E-BX 3 Wire 6" $48 $54 $54
PRTF-10-2-1000-(*)-12-E-BX 3 Wire 12" 48 54 54
PRTF-10-2-1000-(*)-18-E-BX 3 Wire 18" 54 61 61
PRTF-10-2-1000-(*)-24-E-BX 3 Wire 24" 57 64 64
Ordering Example:
BX armor and OTP connector, $54 + 7 = $61.
(Specify Model Number)
1
⁄4" Dia.
PRTF-10-2-1000-1/8-12-E-BX-OTP, 1000 Ω, Class “B” RTD with a 1⁄8" diameter probe 12" long, 40" of 3-wire PFA insulated cable with
Price
3
⁄16" Dia.
1
⁄8" Dia.
C-43
General Purpose RTD Probes
ACCURACY
IEC CLASS
BB
(±0.30ºC @ 0ºC)
With Stainless Steel BX Armor Cable for
Industrial Applications
Metric Dimensions
C
⻬ Transitions Directly to Lead Wires
(No Transitions Fitting)
⻬ Compact Design for Applications
with Space Restrictions
⻬ Available in Standard and
Metric Sizes
Starts at
Probe length specified by customer
$
48
1 m of #26 AWG stranded
nickel-plated copper, fiberglass
insulated, fiberglass jacketed
cable with SST BX armor
Note: BX armor is attached to
outside of sheath
PRTF-10-2-100-M60-300-E-BX,
$48, shown smaller than
actual size.
100 Ω Sensor
To Order
Model Number Lead Wire Style Sheath Length 6 mm Dia. 4.5 mm Dia. 3 mm Dia.
PRTF-10-2-100-(*)-150-E-BX 3 Wire 150 mm $48 $54 $54
PRTF-10-2-100-(*)-300-E-BX 3 Wire 300 mm 48 54 54
PRTF-10-2-100-(*)-450-E-BX 3 Wire 450 mm 54 61 61
PRTF-10-2-100-(*)-600-E-BX 3 Wire 600 mm 57 64 64
Specify “-M30” for 3 mm, “-M45” for 4.5 mm or “-M60” for 6 mm for probe diameter in millimeters. To order 4-wire sensors, change “-2” to “-3”
*
in the model number and add $5 to the price. To order with shrink tube strain relief, specify “-ST” at end of model number, no additional charge.
To order probes in intermediate lengths (50 mm minimum), change length in model number and use next longer probe price. For probe lengths
over 600 mm, change length in model number and add $1 per 25 mm of probe length. Cable length refers to length of metal hose with cable
extending 150 mm minimum from end of metal hose. For metal hose lengths longer than 1 meter, add length to end of the model number and add
$7.50 per meter. For MTP or OTP connectors, add “MTP” or “-OTP” to model number and $7.
Ordering Example: PRTF-10-2-100-M45-150-E-BX-OTP, 100 Ω, Class “B” RTD with a 4.5 mm diameter by 150 mm long probe, 1 m of 3-wire
cable with BX armor and OTP connector, $54 + 7 = $61.
1000 Ω Sensor
To Order
Model Number Lead Wire Style Sheath Length 6 mm Dia. 4.5 mm Dia. 3 mm Dia.
PRTF-10-2-1000-(*)-150-E-BX 3 Wire 150 mm $48 $54 $54
PRTF-10-2-1000-(*)-300-E-BX 3 Wire 300 mm 48 54 54
PRTF-10-2-1000-(*)-450-E-BX 3 Wire 450 mm 54 61 61
PRTF-10-2-1000-(*)-600-E-BX 3 Wire 600 mm 57 64 64
Ordering Example: PRTF-10-2-1000-M30-300-E-BX-OTP, 1000 Ω, Class “B” RTD with 3 mm diameter probe 300 mm long, 1 m of 3-wire PFA
insulated
(Specify Model Number)
(Specify Model Number)
cable with BX armor and OTP connector, $54 + 7 = $61.
⻬ Temperature Range: -50 to 500°C
Precision Thin Film 100 or 1000 Ω, Class B DIN Platinum
⻬
Elements per IEC60751 (alpha = 0.00385 Ω/Ω/°C)
⻬ 2-, 3-, 4-Wire Constructions Available
⻬ All Sensors Supplied to IEC60751/ASTM E-1137
Color Codes
300
Probe Length
(50 mm minimum)
PFA Coating
Available, See
Page C-92
(See ordering example)
Probe Diameters:
Metric = 6, 4.5, 3 mm
Stripped lead wires
standard. Optional
connectors available,
see section G.
150 mm
Series
stainless
steel probe
MOST POPULAR MODELS HIGHLIGHTED!
Price
Price
C-44