Omega Products PHA-52 User Manual

Specifications
Input: 4 to 20 mA non isolated Output: 4 to 20 mA Isolated Insertion loss at 20 mA: 4.5 Vdc
(this represents a max. resistance of 225 ohms into the 4 to 20 mA loop)
Allowable Isolated Load:
20 to 500 ohms Isolation: 1000 Vac or dc, transformer
isolated
Sensitivity: 0.01 mA Stability: 0.01 mA Non-linearity: ±0.03% of span Accuracy: ±0.1% Temperature Range: -20 to 50°C Dimensions: 62.2mm H x 53.3mm W x
48mm D (2.45'' x 2.10'' x 1.89'')
Models
PHA-51 and PHA-52
Dual Alarm Modules
Adds Alarm Relay
Capability to Common Analog Outputs
Ideal for Use with Two
Wire Transmitters
Independent Setpoint
and Dead Band Controls for Each Relay
Relays Energize on
Increasing or Decreasing Input Value-Switch Selectable
NEMA 4X Gasketed
Enclosure Provides Watertight Protection
The Model PHA-51 and PHA-52 dual alarm modules provide an ideal way to add alarm capability to a control system loop. The module’s two relays each have setpoint and deadband controls and an LED to indicate on/off relay status. Relay phasing switches individually select each relay to operate in response to increasing or decreasing input signal value. For compatibility with many systems, input levels are user selectable. The PHA-51 accepts 0 to 20 mA, 4 to 20 mA, or 0 to 5Vdc inputs and the PHA-52 takes 0 to 50 mV, 0 to 100 mV, 0 to 5 Vdc.
Specifications
Inputs: PHA-51: 0 to 20 mA, 4 to 20
mA, 0 to 5 Vdc; PHA-52: 0 to 50 mV, 0 to 100 mV, 0 to 5 Vdc
Outputs: 0 to 5 Vdc, 100 K ohms min. load; 0 to 1 mA, 100 ohms max.
Power: 100 - 130 Vac Relays: Setpoints: 0 to 100% of Input
Signal Range; Deadbands: 0 to 50% of Signal Input Range; Contact Rating: SPDT, 3A max. resistive, 250 Vac max. 3A max. resistive, 30 Vdc max.
Dimensions: 120.6mm H x 120.6mm W x 63.5mm D x (4.75" x 4.75" x 2.5")
Weight: 567g (1.25 lb)
Model PHA-51
$
215
Model PHA-50
$
175
Model PHA-50
Loop Powered Isolator
Prevents Ground LoopsTransformer IsolatedLoop PoweredVirtually Zero
Temperature Drift
The PHA-50 loop-powered isolator provides an isolated 4 to 20 mA output equal to the 4 to 20 mA non isolated input. This one to one current isolator is used in 4 to 20 mA two wire circuits to prevent ground loops. To eliminate moisture and humidity problems, the electronics are encapsulated in epoxy and the output is compensated for virtually zero temperature drift. The PHA-50 can be surface mounted in any position, and a trimpot control to adjust the output span is accessed by removing a protective cap.
Model PHA-51
Model PHA-50
To Order (Specify Model No.)
Model No. Price Description PHA-50 $175 Loop power isolator PHA-51 215 Dual alarm module (4-20 mA, 0-5 Vdc) PHA-52 255 Dual alarm module (millivolt, 0 to 5 Vdc)
Alarm Module and Isolator