Omega Products OSXL-101 User Manual

Thermal Imager
OSXL-101
Series
$
1990
Thermal Imager with
Ethernet Connection
Easy to Use and
Implement
2256 Pixel ResolutionBuilt-In AlarmsNEMA 4 (IP65)
Specifications
Temp Range: -20 to 300°C (-4 to 572°F) Working Temp: -10 to 50°C
(14 to 122°F) Working RH: 10 to 80% RH
(no dew condensation)
Temperature Resolution: 0.5°C Accuracy: ±2% of reading or ±3°C
whichever larger (at ambient temp of 25°C ±2°C)
Detector: Thermopile array, 48 x 47 pixels
Wavelength: Center wavelength 10µm Viewable Angle: 60°x 60° or 25° x 25° Radius Resolution: 21.8 mrad Frame Speed: 3 fps (1 fps for alarm
output)
Focus: Fixed focus Emissivity: 0.10 to 1.00 Ethernet: 10BASE-T/100BASE-TX Alarm: 2 SPST (non-voltage contact
output)
Power Supply: 9 to 30 Vdc Power Consumption:
Max 2VA @ 12 Vdc Inrush Current: Max 1.3A @ 12 Vdc (The inrush current should be
considered for the selection of power)
Casing: Polycarbonate (color: black) Weight: Approx. 150 g (5.2 oz)
(sensor only) Protection: NEMA 4 (IP65) (with
provided exclusive cable and tripod screw)
Standards: CE (EN61326 Annex A)
OSXL-101, $1990, shown with mounting stand (included).
Thermal imaging software included.
Thermal image PC screen of 4 sensors (maximum) connected.
J-7
Mounting stand features a ball-socket fitting for full range of motion.
Thermal image PC screen of 1 sensor connected.
Functions
1 m
(3.28')
3 m
(9.84')
5 m
(16.4')
1.4 m (4.6')
29 mm
(1.2")
88 mm (3.5")
146 mm
(5.7")
4.2 m (13.8')
7.0 m (23')
View per pixel
For accurate measurements, 8 x 8 pixels or more for a target is recomended.
POWER SUPPLY (12-24 V DC)
LAN
PLC
LAN
ALARM OUTPUT1
ALARM OUTPUT2
POWER SUPPLY (12 -24 V DC)
1 m
(3.28')
3 m
(9.84')
5 m
(16.4')
0.5 m (1.64')
10 mm (0.40")
31 mm (0.10")
52 mm (0.17")
1.5 m (4.9')
2.5 m (8.2')
View per pixel
For accurate measurements, 5 x 5 pixels or more for a target is recomended.
USB/LAN
ALARM OUTPUT1
ALARM OUTPUT2
POWER SUPPLY (12-24 V DC)
Monitoring Mode
The temperature data is outputted continuously by a command from the PC
Monitor Mode
Multiple Unit Connection (LAN)
Up to 4 sensors can be connectedMonitoring and alarm outputs from
sensor can be used together
Monitor lamp–state of operation indicated in blue, red, and purple
9 to 30 Vdc powerinput/contact alarm output (cable and power supply included)
Monitor Mode
Single Unit Usage
Single unit can monitor 1 area and has
2 alarm outputs
When alarm goes on, the unit stores 1 image
to the memory
Image saving updates every occurrence of alarmReading the data from host PC is possible
Capturing Mode
The temperature data is outputted row-by-row horizontally by a command from PLC, etc.
Connectivity
Up to 4 sensors can be connected to a PC via LAN and viewer software allows you to monitor thermal images, measuring temperature and alarms.
Capturing Mode
PLC Connection
The temperature data is outputted row-by-row
horizontally by a command from PLC, etc
Lens–measurement range:
-20 to 300°C (-4 to 572°F)
LAN connection [2.5 m (8.2') cable included]
Measuring Spot Size and Distance: OSXL-101
J
Distance 1 m (3.28') 3 m (9.84') 5 m (16.4')
Width
m (ft)
Width/Pix
mm (in)
Measuring Spot Size and Distance: OSXL-101-25
1.4 (4.6) 4.2 (13.8) 7.0 (23)
29 (1.2) 88 (3.5) 146 (5.7)
J-8
Distance 1 m (3.28') 3 m (9.84') 5 m (16.4')
Width
m (ft)
Width/Pix
mm (in)
0.5 (1.64) 1.5 (4.9) 2.5 (8.2)
10 (0.4) 31 (0.1) 52 (0.17)