Omega Products OMPS300A48 User Manual

Power SuPPlieS
For oPen Frame StePPer DriveS
OMPS Series
l Universal Input Voltage Range
from 85 to 265 Vac
l Built-In Active PFC Filter,
PF>0.95, Conforms to EN61000-3-2
l Pending for Safety Approvals:
CE, CCC, UL/CSA/EN60950
l EMI: Conform to EN55011-B,
EN55022-B, FCC-B
l EMS: Conform to
EN61000-4-2, 3, 4, 5, 6, 8, 11
l LED Power Good Indicator l Peak Current for
Motor Application
l 100% Full Load Burn-In Test,
High Performance, High Reliability
l Compact Size, 15% Smaller
than Conventional Products
OMPS150A24
l 24V Output, Manually Adjustable
Output Voltage
l High Flexibility with 3 Optional
Connection Methods for Input/ Output: Horizontal or Vertical Terminal Block or Connectors to Fit Wire Harness
OMPS300A48
l 48V Output, Manually Adjustable
Output Voltage
l High Flexibility with 2 Optional
Connection Methods for Input/ Output: Horizontal or Vertical Terminal Block
l Fan Speed Control by Output
Current to Extend Lifetime
l Remote Sense to Compensate
Wire/Connection Voltage Drop
Open-frame stepper drives require a separate DC power supply for operation. Omegamation offers two power supplies that are matched for use with our open-frame stepper drive selection: the OMPS150A24 and the OMPS300A48.
Both power supplies are switched-mode, regulated DC power supplies with active PFC filters. The OMPS150A24 is 24 Vdc, 6.3 A (150 W)
while the OMPS300A48 is 48 Vdc,
6.7 A (300 W).
OMPS150A24 SPECIFICATIONS
Nominal Output Voltage: 24V Maximum Output Current: 6.3 A Peak Output Current: 9.5 A Maximum Output Power: 151.2 W Efficiency (Typical) (115/230 Vac)1:
82/85% Input Voltage Range: 85 to 265 Vac
(47 to 63 Hz) or 120 to 370 Vdc Input Current (Typical) (115/230 Vac)1:
1.8/0.9 A Inrush Current (Typical): 16 A at
115 Vac, 32 A at 230 Vac, Ta = 25°C (77°F), cold start
Harmonic Current: Compliance to EN61000-3-2
Power Factor (Typical) (115/230 Vac)
0.99/0.95
Output Voltage Range: 21.6 to 26.4V
1
OMPS150A24 shown smaller than actual size.
OMPS300A48 shown smaller than actual size.
Ripple and Noise (115/230 Vac)
150 mV
Line Regulation2: 96 mV Load Regulation2: 120 mV Temperature Coefficient: Less than
0.02 %/°C
Over Current Protection3: 6.6/9.7 A Over Voltage Protection4: 27.6 to 32.4V Hold-Up Time (Typical)
(115/230 Vac)1: 20 ms Leakage Current: 0.75 mA maximum,
0.25 mA (Typical) at 115 Vac, 0.5 mA (Typical) at 230 Vac
Series Operation: Possible Remote ON/OFF Control:
Option, CN3: 4 to 10V, Power ON; 0 to 0.8V, Power OFF
Operating Temperature: -10 to 70°C (14 to 158°F)
Operating Humidity: 20 to 90% RH (no dewdrop)
Storage Temperature: -30 to 85°C (-22 to 185°F)
Storage Humidity: 10 to 95% RH (no dewdrop)
Cooling Method: Convection cooling/ forced air cooling
Withstand Voltage: Input - Output: 3.0 KVac (20 mA)
Input - FG: 2.0 KVac (20 mA) Output - FG: 500 Vac (100 mA) for 1 minute
:
Isolation Resistance: More than
100 MΩ at Ta = 25°C (77°F) and 70% RH, Output - FG: 500 Vdc
1, 2
:
D-37
115
(4.53)
11
(0.44)
11
(0.44)
65
(2.56)
64
(2.52)
50
(1.95)
25
(0.98)
14
(0.54)
57
(2.24)
117
(4.61)
215
(8.46)
50
(1.97)
Vibration: At no operating, 10 to 55 Hz, 10 min 1 cycle 19.6m/s2 constant, X, Y, Z, 1 hour each
Safety: Pending, UL60950, CSA60950, EN60950
EMI5: Compliance to FCC-Class B, EN55011/EN55022-B,CISPR22 Class B
EMS Immunity5: Compliance to EN61000-4-2, -3, -4, -5, -6, -8, -11
Weight (Typical): 620 g (21.87 oz) Dimensions: 50 x 99 x 199 mm
(1.97 x 3.9 x 7.83")
1
At maximum output power, nominal input
voltage, Ta = 25°C (77°F).
2
Ripple and noise measured at bandwidth of 20 MHz by using a 12” twisted pair-wire terminated with 0.1uF and 47uF parallel capacitors.
3
Constant current limit with automatic recovery. Avoid operating at overload or dead short for more than 60 seconds.
4
Shutdown output voltage, manual reset. Re-power on to recover.
5
This power supply is considered a component to be installed in final equipment which should be re-confirmed to meet EMC directives.
OMPS300A48 SPECIFICATIONS
Nominal Output Voltage: 48V Maximum Output Current: 6.7 A Peak Output Current: 8.7 A Maximum Output Power: 321.6 W Efficiency (Typical) (115/230 Vac)1:
80/85% Input Voltage Range: 85 to 265 Vac
(47 to 63 Hz) or 120 to 370 Vdc
Input Current (Typical) (115/230 Vac)
3.6/1.8 A Inrush Current (Typical): 20 A at
115 Vac, 32 A at 230 Vac, Ta = 25°C (77°F), cold start
Harmonic Current: Compliance to EN61000-3-2
Power Factor (Typical) (115/230 Vac)1:
0.99/0.95
Output Voltage Range: 43.2 to 52.8 Ripple and Noise (115/230 Vac)
1, 2
:
240 mV
Line Regulation2: 96 mV Load Regulation2: 240 mV Temperature Coefficient: Less than
0.02%/°C
Over Current Protection3: 7.0/8.9 A Over Voltage Protection4: 55.2 to 64.8V
Over Temperature Protection: Yes Hold-Up Time (Typical)
(115/230 Vac)1: 20 ms Leakage Current: 0.75 mA maximum,
0.25 mA (typical) at 115 Vac, 0.5 mA (typical) at 230 Vac
Series Operation: Yes Remote ON/OFF Control:
Option, CN2: 4 to 10V, power ON; 0 to 0.8V, power OFF
Remote Sensing: Option Operating Temperature: -10 to 65°C
(14 to 149°F) Operating Humidity: 20 to 90% RH
(no dewdrop) Storage Temperature: -30 to 85°C
(-22 to 185°F) Storage Humidity: 10 to 95% RH
(no dewdrop)
1
:
Cooling Method:
Forced air by blower fan
Withstand Voltage: Input - Output: 3.0 KVac (20 mA)
Input - FG: 2.0 KVac (20 mA) Output - FG: 500 Vac (100 mA) for 1 minute
Isolation Resistance: More than 100M Ω at Ta = 25°C (77°F) and 70% RH, Output - FG: 500 Vdc
Vibration: At no operating, 10 to 55 Hz, 10 min 1 cycle 19.6 m/s2 constant, X, Y, Z, 1 hour each
Safety: Pending, UL60950, CSA60950, EN60950
EMI5: Compliance to FCC-Class B, EN55011/EN55022-B,CISPR22 Class B
EMS Immunity5: Compliance to EN61000-4-2, -3, -4, -5, -6, -8, -11
Weight (Typical): 900 g (31.75 oz) Dimensions: 50 x 115 x 215 mm
(1.97 x 4.53 x 8.46")
1
At maximum output power, nominal input
voltage, Ta = 25°C (77°F).
2
Ripple and noise measured at bandwidth of 20 MHz by using a 12" twisted pair-wire terminated with 0.1uF and 47uF parallel capacitors.
3
Constant current limit with automatic recovery. Avoid operating at overload or dead short for more than 60 seconds.
4
Shutdown output voltage, manual reset. Re-power on to recover.
5
This power supply is considered a component to be installed in final equipment which should be re-confirmed to meet EMC directives.
D
Drives and Motors
OMPS150A24OMPS300A48
50
(1.97)
25
(0.98)
(1.65)
(1.58)
40
(1.58)
Dimensions: mm (inch)
D-38
199
(7.83)
42
40
65
(2.56)
117
(4.61)
45
(1.77)
50
(1.95)
(3.90)
25
(0.98)
99
12
(0.49)
Loading...