Omega Products OMP-MODL-EXM User Manual

OMP-MODL Modular Portable Data Logging and Alarming System
$
1040
Basic Unit
Modular Design Allows
Flexibility to Meet Your Application Requirements
Fully User Programmable
Via Graphic Drag-and­Drop Icons
Universal Analog Inputs
Accepts Thermocouple,
Voltage, Current, Frequency, RTD, Thermistor and Resistance Inputs
Up to 48 Digital
Inputs/Alarm Outputs
One High-Speed
Counter/Event Input
Conditional Logging,
Math, Integrals, Delta Logging and Much More
Low Power for Battery
or Line Powered Use
Full Differential,
Bipolar Inputs
Modem Option with
Pager Alarm Output
Real-Time Trending to a PC
Via Modem or RS-232 Link
16,000 Sample Capacity
(up to 400,000 When Using PCMCIA Memory Card)
Provided Complete with
HyperWare Windows Software
OMEGACARESMextended warranty program is available for models shown on this page. Ask your sales representative for full details when placing an order. OMEGACARE covers parts, labor and equivalent loaners
The OMP-MODL Modulogger is a self-contained, battery or line-powered datalogger and alarm system, which can be deployed as a “stand-alone” system, or incorporated into equipment where it silently samples digital and analog inputs, storing them to internal or PCMCIA memory. Easily programmed, the OMP-MODL has extremely powerful processing capabilities for data reduction (averaging, min/max, etc.) mathematical manipulation (algebraic, trig, time integrals, etc.) as well as unlimited, user-programmable, intelligent data logging capabilities. Together with the supplied Hyperware for Windows software, the OMP-MODL is a powerful, fully user programmable datalogging and alarming system. The Hyperware software provides for graphical programming of the OMP-MODL, serial communications, real-time trending, plotting and spreadsheet conversion of collected data. The OMP-MODL consists of a user specified stack of ruggedly packaged, rectangular modules. The main CPU module can be expanded with additional analog inputs, digital I/O, display and memory expansion modules to meet your specific application needs.
SM
CPU Module
A CPU module is required in all OMP-MODL systems as it contains the system microprocessor, data storage memory, 13 bit Analog to Digital converter basic user switches and indicators, RS-232 port and Cold Junction Compensation circuitry. It also includes four alarm outputs, four universal analog inputs, and one digital count/event input. The provided analog inputs are software configurable for 6 thermocouple types,15 ranges of DC voltage or 7 ranges of DC current (identical function/specs as add-on OMP-MLIM-1 Module).
Modulogger Expanded View
Each of the analog input channels sports full differential inputs, software programmable configuration, front-end completion circuitry and rugged suppression protection circuitry to insure reliable accurate readings. The CPU module also includes a Cold Junction Compensation input for thermocouple applications. If thermocouples are not used, the CJC channel can be used as a system temperature, resistance, thermistor, or contact closure input. A single software configurable, general-purpose digital input is provided for logging of events or counting pulse outputs from flow meters, encoders, or other pulse-train type sources.
E-67
The CPU module also provides two isolated alarm relay outputs, a TTL alarm output, a Status LED and a regulated, current-limited 5 Vdc output, all controllable via software. “Enable”, “Stop” and “Reset” switches as well as LED status indicators are provided at one end of the CPU module. Input and Output wiring is handled through plug-in terminal strips which allow for mass connection and disconnection of wiring.
Expansion Modules
A full family of plug-on modules is available to expand the capability and features of the system. Modules are available for additional analog inputs, digital I/O, modem communication, PCMCIA memory card interface, user interface/display, and battery power. As modules are added, they stack onto the CPU module, building a layered instrument to meet your needs. Modules are self-identifying and configurable via the Hyperware software for input type and range within the module’s capability (e.g., the MLIM-4 accepts 2, 3, and 4 wire RTD, resistance and thermistor inputs each with a multitude of ranges, all under software control).
Real Time Trending
E
Applications
Designed for portable, plant floor, and long-term remote data collection applications, the OMP-MODL incorporates low power CMOS circuitry to provide up to 4 weeks of operation from its optional plug-on D-cell battery pack. A low-voltage power transformer can be used for indefinite logging.
Software
HyperWare for Windows is a powerful multi-purpose software package provided with the OMP-MODL. It facilitates serial communications, provides for graphic programming of the OMP-MODL, real-time data trending, collected data graphic plotting and data export to other applications, such as Microsoft Excel.
Drag and Drop Graphics Programming
Graphic RS-232/Modem Communications
E-68
Specifications
Data Storage Memory: Redundant
battery backed up SRAM. Approx. 16,000 samples for OMP-MODL and up to 80,000 with OMP-MNL­EXM. Up to 500,000 reading when using PCMCIA memory cards.
Data Memory Backup:
Lithium cell, 1 year @ 25°C
Memory Utilization:
User programmable; Stops either when memory is full, or rotary (FIFO).
A/D Converter: 12-bit plus sign (13 bit) SAR converter. Programmable first-order filtering and 50/60 Hz noise rejection options.
A/D Converter Accuracy:
±0.1% RDG + 1 bit
Sampling Throughput Rate:
150 samples per second max. (analog input to memory); rate is dependent on number and type of channels and programmed signal processing. Sampling rates are configurable for each channel.
Digital Input: One general purpose digital input channel. User pro­grammable for event or high-speed counter applications. Contact closure or TTL driven signal input (15 Vdc max)
Outputs: 2 low voltage N.O. relays, 500 mA rated; 1 current limited TTL digital output; 100 mA @5 Vdc regulated output (short circuit protected)
Real-Time Clock: Date and time, 24 hour battery backed up
Glitch Recovery: Hardware watchdog reset followed by software restart of last operation.
Power Consumption: 9 Vdc nominal. Approx. 5 mA between readings, approx. 50 mA during readings provided by optional battery pack (6 internal D-cells)
External Power: Terminal strip connection for external power source. Accepts 10-32 Vdc or 10-26 Vac from any semi-regulated external source (120 Vac wall adapter is included with OMP-MNL). Fuse and Transzorb protected.
Operating Temperature/Humidity:
-10 to 60°C (14 to 140°F), 90% RH non-condensing
Mechanical: Dust sealed.
8.8 W x 4.8 H x 2.2" D (3.8" H with battery pack attached) 1.5 lb. (3 lb. with battery pack)
Expansion Modules:
Modular design allows flexibility to meet your specific application requirements. The following modules may be mixed and matched (5 modules can be attached).
Cold Junction Compensation Range (CJC):
-10 to 60°C (14 to 140°F)
DC VOLTAGE INPUTS Full Scale Ranges:
±20 mV, ±40 mV, ±50 mV, ±60 mV, ±100 mV, ±200 mV, ±1 V, ±2 V, ±5 V, ±10 V, ±30 V
Accuracy:
±0.5% F.S. for ±10 V and +30 V range. All other ranges ±0.3% F.S.
Common Mode Range:
3.5 Vdc, full differential inputs.
Input Resistance:
>2.5 M for 5, 10, and 30 Vdc; >10 M for all other ranges.
DC CURRENT INPUTS Full Scale Ranges:
±200 µA, ±400 µA, ±500 µA, ±1 mA, ±2 mA, ±11 mA, ±22 mA
Accuracy: ±0.3% F.S. Input Resistance:
100 Ω (all current ranges)
OMP-MLIM-2, 4 INPUT/4 OUTPUT OUNTER/TIMER/EVENT INTERFACE MODULE
Provides 4 individually programmable channels of digital signal input and 4 outputs. Any combination of the following input types can be configured on a module:
Frequency: 5 Hz to 30 KHz, 300 mV p-p minimum input amplitude, 15 V p-p maximum
Event: Contact closure or TTL input (0 to 15 Vdc max). 1 second resolution (or 5 msec in millisecond mode). Software controlled 50 msec debounce option.
Counter: Contact closure or TTL input (0 to 15 Vdc max). 20 KHz maximum input frequency. Software controlled 50 msec debounce option. 16 million maximum accumulated counts between reads.
Digital Outputs: (4 separate channels): Low output = tri-state (floating); High output = 4.0 Vdc @ 1 mA, 3.2 Vdc @ 10 mA. Short circuit protected. Max current = 12 mA (approx.) per channel.
OMP-MLIM-8, 8 CHANNEL DIGITAL I/O INTERFACE MODULE
Eight channel digital I/O allows for user configuration of 8 channels as inputs or outputs (individually selectable)
Input Signal: Contact closure or TTL input (0 to 26 Vdc max). 1 second resolution (or 5 msec in millisecond mode). Software controlled 50 msec debounce option.
Output Signal:
Low output = tri-state (floating); High output = 4.0 Vdc @ 3 mA, short circuit protected. Max current = 3 mA (approx.) per channel.
OMP-MLIM-4, 4 CHANNEL RTD/THERMISTOR/RESISTANCE INTERFACE MODULE
Measures any combination of the following input types:
RTD: Type:
100 Ω and 1000 Ω α = 0.00385 and 0.00392
Ranges: -200 to 850°C and
-200 to 300°C Accuracy: ±0.1°C to 0.4°C
depending on range and wiring configuration
Configurations Supported: 2-wire, 3-wire, and 4-wire. (3 and 4 wire configurations use 2 input channels)
THERMISTOR: Thermistor Type: 10k @ 25°C
(Fenwall #16 or equivalent) Ranges: -32 to 180°C; -4 to 180°C;
10 to 180°C; 25 to 180°C Accuracy: ±0.2°C to ±0.5°C
depending on range.
RESISTANCE: Ranges: 12 ranges, from 200 Ω Full
Scale to 400,000 Ω Full Scale
Accuracy:
±0.1 to ±0.3% of Rdg. Depending on range and wiring configuration.
Configurations Supported: 2-wire, 3-wire, and 4-wire. (3 and 4 wire configurations use 2 input channels)
E-69
Thermocouple Input Ranges
Thermocouple Maximum Range Accuracy*
Iron-Constantan 0 to 760°C 32 to 1400°F ±1°C ±1.8°F CHROMEGA®-ALOMEGA CHROMEGA®-Constantan -100 to 1000°C -148 to 1832°F ±1°C ±1.8°F Copper-Constantan -160 to 400°C -256 to 752°F ±1°C ±1.8°F Pt/13%Rh-Pt 0 to 1000°C 32 to 1832°F ±10°C ±18°F Pt/10%Rh-Pt 0 to 1750°C 32 to 3182°F ±10°C ±18°F
* Plus ±0.5°C CJC accuracy
®
0 to 1370°C 32 to 2498°F ±1.2°C ±2.2°F
To Order
(Specify Model Number)
Model Number Price Description
OMP-MODL* $1040 Portable data logging system with 16,000 reading memory with 4 universal analog inputs,
OMP-MODL-EXM* 1140 Portable data logging system with 80,000 reading memory with 4 universal analog inputs,
OMP-MODL-OEM 780 Portable data logger with 16,000 reading memory reading memory with 4 universal
OMP-MODL-EXM-OEM 880 Portable data logger with 80,000 reading memory with 4 universal analog inputs,
*Note: OMP-MODL-TOP and OMP-MODL-BACK are required if not using the OMP-DISP and OMP-MNL-BATT. See Options and Accessories. Ordering Example: OMP-MODL with OMP-MNL-BATT and OMEGACARESM1 year extended warranty for OMP-MODL (adds 1 year to
standard 1 year warranty), $1040 + 65 + 104 = $1209.
one digital input and 4 discrete outputs. Includes Hyperware software, serial cable, AC adapter and user manual
one digital input and 4 discrete outputs. Includes Hyperware software, serial cable, AC adapter and user manual
analog inputs, one digital input and 4 discrete outputs. Does not include software, cables, AC adapter or user manual
one digital input and 4 discrete outputs. Does not include software, cables, AC adapter or user manual
Options and Accessories
Model Number Price Description
OMP-ML-DISP-MDL $140 Display Module with 2 line x 16 character LCD and front panel user switches OMP-MLIM-1 190 Analog interface module; 4 channels of thermocouple, DC voltage and/or DC current inputs
OMP-MLIM-2 150 Digital interface module; 4 channels of frequency, event, and/or count input (individually
OMP-MLIM-4 180 Resistance interface module; 4 channels of RTD, thermistor and/or resistance inputs
OMP-MLIM-5 120 PCMCIA interface module; includes socket for SRAM memory cards
OMP-MLIM-8 140 Digital I/O interface module; 8 channels, individually configurable as inputs
OMP-MODL-TOP 12 Top cover plate (required if OMP-DISP is not used) OMP-MODL-BACK 24 Back cover/mounting plate (required if OMP-MNL-BATT is not used) OMP-MLIM-5-144 240 Modem/PCMCIA interface module; includes 14400 baud modem and socket for SRAM memory
OM-320-MC-50* 120 PCMCIA SRAM memory card - approx. 65,000 samples (requires any OMP-MLIM-5 interface modules) OM-320-MC-200* 160 PCMCIA SRAM memory card - approx. 250,000 samples (requires any OMP-MLIM-5 interface modules) OM-320-MC-400* 260 PCMCIA SRAM memory card - approx. 500,000 samples (requires any OMP-MLIM-5 interface modules) OM-320-PD-2 280 PCMCIA drive connects to IBM PC serial port or USB port for reading data from PCMCIA
OMP-MNL-BATT 65 Battery pack module (w/ 6 D-Cells). Attaches to OMP-MNL dataloggers OM-220-RPS-1 395 Rechargeable power supply for sensor excitation and auxiliary logger power.
OM-220-CHGR-12 150 Battery charger for stand-alone charging of batteries when not installed in OM-220-RPS-1
* The number of readings that each PCMCIA can store depends on the types of inputs that you are storing. For example, Digital I/O uses less memory than Analog inputs, so you can store more readings, therefore, the values listed above are approximations.
(individually selectable)
selectable), plus 4 digital outputs
(individually selectable)
(requires PCMCIA SRAM card)
(contact closure or TTL) or outputs (0-4 V @ 3 mA)
cards (requires PCMCIA SRAM card)
SRAM cards. Includes software drivers.
Dual outputs programmable from 3.5 Vdc-22 Vdc
(115 Vac input)
E
E-70
One Omega Drive | Stamford, CT 06907 | 1-888-TC-OMEGA (1-888-826-6342) | info@omega.com
EPG05
www.omega.com
UNITED KINGDOM
www. omega.co.uk
Manchester, England
0800-488-488
UNITED STATES
www.omega.com
1-800-TC-OMEGA
Stamford, CT.
CANADA
www.omega.ca
Laval(Quebec)
1-800-TC-OMEGA
GERMANY
www.omega.de
Deckenpfronn, Germany
0800-8266342
Karviná, Czech Republic
FRANCE
www.omega.fr
Guyancourt, France
088-466-342
CZECH REPUBLIC
www.omegaeng.cz
596-311-899
BENELUX
www.omega.nl
Amstelveen, NL 0800-099-33-44
More than 100,000 Products Available!
Temperature
Calibrators, Connectors, General Test and Measurement Instruments, Glass Bulb Thermometers, Handheld Instruments for Temperature Measurement, Ice Point References, Indicating Labels, Crayons, Cements and Lacquers, Infrared Temperature Measurement Instruments, Recorders Relative Humidity Measurement Instruments, RTD Probes, Elements and Assemblies, Temperature & Process Meters, Timers and Counters, Temperature and Process Controllers and Power Switching Devices, Thermistor Elements, Probes and Assemblies,Thermocouples Thermowells and Head and Well Assemblies, Transmitters, Wire
Flow and Level
Air Velocity Indicators, Doppler Flowmeters, Level Measurement, Magnetic Flowmeters, Mass Flowmeters, Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area Flowmeters, Vortex Shedding Flowmeters
pH and Conductivity
Conductivity Instrumentation, Dissolved Oxygen Instrumentation, Environmental Instrumentation, pH Electrodes and Instruments, Water and Soil Analysis Instrumentation
Data Acquisition
Auto-Dialers and Alarm Monitoring Systems, Communication Products and Converters, Data Acquisition and Analysis Software, Data Loggers Plug-in Cards, Signal Conditioners, USB, RS232, RS485 and Parallel Port Data Acquisition Systems, Wireless Transmitters and Receivers
Pressure, Strain and Force
Displacement Transducers, Dynamic Measurement Force Sensors, Instrumentation for Pressure and Strain Measurements, Load Cells, Pressure Gauges, Pressure Reference Section, Pressure Switches, Pressure Transducers, Proximity Transducers, Regulators, Strain Gages, Torque Transducers, Valves
Heaters
Band Heaters, Cartridge Heaters, Circulation Heaters, Comfort Heaters, Controllers, Meters and Switching Devices, Flexible Heaters, General Test and Measurement Instruments, Heater Hook-up Wire, Heating Cable Systems, Immersion Heaters, Process Air and Duct, Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters