Omega Products OM-CP-SQ2010 User Manual

Extended Warranty
Program
SM
Portable Data Logger
OM-CP-SQ2010
4 to 8 Universal Analog Inputs (Current, Voltage, Resistance, Temperature) Plus 8 Digital Inputs
16 Derived/Calculated Channels
2 Alarm Outputs and 2 Pulse Counter Inputs (1 at 64 KHz, 1 at 100 Hz)
0.1% Accuracy
Up to 1.8 Million Readings
Large Easy-to-Read Graphical Display
Includes Windows®Software for Data Logger Setup and Data Transfer to PC
USB Connectivity
RS-232 Output For Modem and Wireless Connection (Via Interface Modules)
The OM-SQ2010 is a versatile general purpose data logger with 4 to 8 analog input channels to measure current, voltage, resistance and temperature, plus 8 digital channels to automatically trigger or stop logging. An RS-232 port is included, allowing connection to modems and other networking devices.
This is a portable data logger which is also suitable for benchtop and fixed installations. The unit is easily programmed via the four integral push buttons and large graphical display or via the included Windows
®
software. The OM-SQ2010 is able to fulfill many routine data logging needs, including more demanding applications requiring up to ten readings per second on one channel.
Comprehensive Software Configuration:
The OM-SQ-SOFT software (supplied with the OM-SQ2010 series data loggers) allows logger configuration, data download and data export while giving the user full control over the OM-SQ2010. The optional OM-SQ-SOFT-PLUS software gives the user access to many advanced data analysis and data archiving/transfer features.
To Order, Call or Shop Online at omega.com
OM-SQ2010 data logger, shown smaller than actual size.
The optional OM-SQ-SOFT-PLUS software lets you quickly and easily analyze the data from your OM-SQ2010 data logger in a familiar windows explorer style interface. Data can be displayed with 2 different auto scaling Y-axis. This is particularly useful when displaying widely varying data from different sensors on one graph.
Templates can be setup with any of these combinations and saves time when preparing similar presentations of data
Specifications
No. of Analog Channels:
8 single ended or 4 differential inputs. The OM-SQ2010 data logger has a single analog to digital converter (A/D) which corresponds
You can also zoom in on areas of interest, use a cursor to pick out exact values, times and dates, get a statistical summary of your data, set high and low alarm thresholds and, using the calculation function, you can create new virtual channels from existing channels.
to inputs on blocks A and B. Each connection block will accept up to 2 differential inputs or up to 4 single ended inputs (it is not possible to mix single ended and differential inputs on a block).
Analog Input Connections:
Detachable screw terminal blocks Channel Expansion: No
The OM-SQ-SOFT-PLUS software also incorporates a report generation facility, which allows you to create custom report templates consisting of a title page with descriptive text, headers and footers, graphs, tabular list of data, statistics and data logger
Universal Input: Yes Voltage Ranges (Differential and Single Ended):
-6 to 25, -0.6 to 2.4, ±0.3V,
-0.15 to 0.15, -0.075 to 0.075,
-6 to 12, -6 to 6, -3 to 3, -0.6 to 1.2,
-0.6 to 0.6
setup information.
.
OMEGACARESMextended warranty program
is available for models shown on this page.
Ask your sales respresentative for full details
when placing an order. OMEGACARE
covers parts, labor and equivalent loaners.
SM
OM-SQ-SOFT, Windows software (included with OM-SQ2010 data loggers) displays data in graphical or tabular format.
SM
1
Power output for sensor excitation/external devices
Easy to use, removable connector system
USB, and RS232 connectivity for quick and easy PC and peripherals communication e.g. Ethernet converter, wi-fi wireless converter or GSM modem
4 to 8 universal analog inputs (4 differential, 8 single ended) for recording temperature, current, voltage and resistance
Range of trigger functions via 8 digital inputs; 2 pulse rate/counter inputs; 2 alarm/relay outputs
OM-SQ2010 data logger, back view, shown smaller than actual size
Power supply–internal alkaline batteries, external DC power or via USB connection to PC
Common Mode: 25V Current Ranges, Differential (Requires External 10 Shunt):
4 to 20 mA, ±30 mA
Thermocouple Ranges (Differential and Single Ended):
Type J: -200 to 1200°C
(-328 to 2192°F) Type K: -200 to 1372°C (-328 to 2502°F) Type T: -200 to 400°C (-328 to 752°F) Type N: -200 to 1300°C (-328 to 2372°F) Type R: -50 to 1768°C (-58 to 3214°F) Type S: -50 to 1768°C (-58 to 3214°F)
Resistance Ranges (All 2 Wire):
0 to 1250 , 0 to 5000 0 to 20,000 , 0 to 300,000
Thermistor Ranges:
U & UU-Type: -50 to 150°C
(-58 to 302°F)
Y-Type: -50 to 150°C (-58 to 302°F) S-Type: -30 to 150°C (-22 to 302°F)
User-Defined Thermistor: Enter
Steinhart-Hart coefficients or RT pairs Pt100/1000 (2-wire): -200 to 850°C (-328 to 1562°F)
A/D Resolution: 24-bit Accuracy: See table Internal Reference Temperature:
-50 to 150°C (-58 to 302°F) Pulse Count Ranges: 0 to 100 Hz (1 input); 0 to 64 kHz (1 input); 0 to 16,000,000 count
Digital State/Event Ranges:
8 state inputs or 1 x 8 bit binary Digital/Alarm Outputs: 2 open drain FETs, 18V, 0.1A
Digital I/O Connections:
DB25F connector
Clock Resolution/Accuracy:
1s/10 ppm Normal Mode:
Each input sampled at a max rate of 1 rdg per second
Double-Speed (Mains Reject Off): One input can be sampled
at 10 rdgs per second and all others are sampled at a max rate of 1 rdg per second
Input Channels Accuracy @ 23°C
Differential voltage ±(0.1% of reading + 0.05% of full scale)
Single-ended voltage ±(0.1% of reading + 0.1% of full scale) Differential current ±(0.1% of reading + 0.1% of full scale) Resistance (up to 200 ) ±(0.1% of reading + 0.1% of full scale) Thermistors (up to 130°C) ±(0.15% of reading + 0.1% of full scale) Pt100/1000 RTD ±(0.15% of reading + 0.1% of full scale) Differential J, K and N thermocouples (above -50°C) * ±0.1% of full scale Differential R, S and T thermocouples (above -50°C) * ±0.2% of full scale Single-ended J, K and N thermocouples (above -50°C) * ±0.15% of full scale Single-ended R, S and T thermocouples (above -50°C) * ±0.25% of full scale Pulse count and rate ±(0.0011% of reading +1)
* Includes cold junction compensation (CJC) error. Data logger held at constant temperature
No of Intervals: 4 Data Scaling: Included in standard
OM-SQ software Data Statistics: Calculated within OM-SQ-SOFT-PLUS software
Calculated Channels:
Up to 16
Memory Internal:
16 M (1 to 1.8 million readings) Display/Keypad: 128 x 64 dot graphical display, 4 button keypad Power: 2 C cells internal (included), or external 8 to 28 Vdc via AC adaptor and USB when plugged in Battery Life: Up to 5 days with continuous usage while sampling all channels once per second Sensor Power Output: 5 V at 50 mA, external 8 to 28V at 100 mA (when connected) Networking: Via RS-232 to Ethernet adaptor (Model No. OM-SQ-NET-ADAP) Modem Support : Via RS-232 modem (GSM modem kit Model No. OM-SQ-GSM-KIT)
2
To Order, Call or Shop Online at omega.com