Portable Data Logger
OM-CP-SQ2010
⻬
4 to 8 Universal Analog
Inputs (Current, Voltage,
Resistance, Temperature)
Plus 8 Digital Inputs
⻬
16 Derived/Calculated
Channels
⻬
2 Alarm Outputs and 2 Pulse
Counter Inputs (1 at 64 KHz,
1 at 100 Hz)
⻬
0.1% Accuracy
⻬
Up to 1.8 Million Readings
⻬
Large Easy-to-Read
Graphical Display
⻬
Includes Windows®Software
for Data Logger Setup and
Data Transfer to PC
⻬
USB Connectivity
⻬
RS-232 Output For Modem
and Wireless Connection
(Via Interface Modules)
The OM-SQ2010 is a versatile
general purpose data logger
with 4 to 8 analog input channels
to measure current, voltage,
resistance and temperature, plus
8 digital channels to automatically
trigger or stop logging. An RS-232
port is included, allowing connection
to modems and other networking
devices.
This is a portable data logger which
is also suitable for benchtop and
fixed installations. The unit is easily
programmed via the four integral
push buttons and large graphical
display or via the included Windows
®
software. The OM-SQ2010 is able
to fulfill many routine data logging
needs, including more demanding
applications requiring up to ten
readings per second on one channel.
Comprehensive Software
Configuration:
The OM-SQ-SOFT software
(supplied with the OM-SQ2010
series data loggers) allows logger
configuration, data download and
data export while giving the user full
control over the OM-SQ2010. The
optional OM-SQ-SOFT-PLUS
software gives the user access to
many advanced data analysis and
data archiving/transfer features.
To Order, Call or Shop Online at omega.com
OM-SQ2010 data logger, shown smaller than actual size.
The optional OM-SQ-SOFT-PLUS
software lets you quickly and easily
analyze the data from your
OM-SQ2010 data logger in a
familiar windows explorer style
interface. Data can be displayed
with 2 different auto scaling Y-axis.
This is particularly useful when
displaying widely varying data from
different sensors on one graph.
Templates can be setup with any of
these combinations and saves time
when preparing similar presentations
of data
Specifications
No. of Analog Channels:
8 single ended or 4 differential
inputs. The OM-SQ2010 data
logger has a single analog to digital
converter (A/D) which corresponds
You can also zoom in on areas of
interest, use a cursor to pick out
exact values, times and dates, get a
statistical summary of your data, set
high and low alarm thresholds and,
using the calculation function, you
can create new virtual channels
from existing channels.
to inputs on blocks A and B. Each
connection block will accept up to 2
differential inputs or up to 4 single
ended inputs (it is not possible to
mix single ended and differential
inputs on a block).
Analog Input Connections:
Detachable screw terminal blocks
Channel Expansion: No
The OM-SQ-SOFT-PLUS software
also incorporates a report generation
facility, which allows you to create
custom report templates consisting of
a title page with descriptive text,
headers and footers, graphs, tabular
list of data, statistics and data logger
Universal Input: Yes
Voltage Ranges
(Differential and Single Ended):
-6 to 25, -0.6 to 2.4, ±0.3V,
-0.15 to 0.15, -0.075 to 0.075,
-6 to 12, -6 to 6, -3 to 3, -0.6 to 1.2,
-0.6 to 0.6
setup information.
.
OMEGACARESMextended warranty program
is available for models shown on this page.
Ask your sales respresentative for full details
when placing an order. OMEGACARE
covers parts, labor and equivalent loaners.
SM
OM-SQ-SOFT, Windows software
(included with OM-SQ2010 data
loggers) displays data in graphical
or tabular format.
SM
1
Power output for
sensor
excitation/external
devices
Easy to use, removable
connector system
USB, and RS232 connectivity for quick and easy PC and
peripherals communication e.g. Ethernet converter, wi-fi
wireless converter or GSM modem
4 to 8 universal analog inputs (4 differential,
8 single ended) for recording temperature,
current, voltage and resistance
Range of trigger functions via 8 digital
inputs; 2 pulse rate/counter inputs;
2 alarm/relay outputs
OM-SQ2010
data logger,
back view,
shown
smaller than
actual size
Power
supply–internal
alkaline batteries,
external DC power
or via USB
connection to PC
Common Mode: 25V
Current Ranges, Differential
(Requires External 10 Ω Shunt):
4 to 20 mA, ±30 mA
Thermocouple Ranges
(Differential and Single Ended):
Type J: -200 to 1200°C
(-328 to 2192°F)
Type K: -200 to 1372°C
(-328 to 2502°F)
Type T: -200 to 400°C
(-328 to 752°F)
Type N: -200 to 1300°C
(-328 to 2372°F)
Type R: -50 to 1768°C
(-58 to 3214°F)
Type S: -50 to 1768°C
(-58 to 3214°F)
Resistance Ranges (All 2 Wire):
0 to 1250 Ω, 0 to 5000 Ω
0 to 20,000 Ω, 0 to 300,000 Ω
Thermistor Ranges:
U & UU-Type: -50 to 150°C
(-58 to 302°F)
Y-Type: -50 to 150°C (-58 to 302°F)
S-Type: -30 to 150°C (-22 to 302°F)
User-Defined Thermistor: Enter
Steinhart-Hart coefficients or RT pairs
Pt100/1000 (2-wire): -200 to 850°C
(-328 to 1562°F)
A/D Resolution: 24-bit
Accuracy: See table
Internal Reference Temperature:
-50 to 150°C (-58 to 302°F)
Pulse Count Ranges: 0 to 100 Hz
(1 input); 0 to 64 kHz (1 input);
0 to 16,000,000 count
Digital State/Event Ranges:
8 state inputs or 1 x 8 bit binary
Digital/Alarm Outputs: 2 open
drain FETs, 18V, 0.1A
Digital I/O Connections:
DB25F connector
Clock Resolution/Accuracy:
1s/10 ppm Normal Mode:
Each input sampled at a max
rate of 1 rdg per second
Double-Speed (Mains Reject
Off): One input can be sampled
at 10 rdgs per second and all
others are sampled at a max rate
of 1 rdg per second
Input Channels Accuracy @ 23°C
Differential voltage ±(0.1% of reading + 0.05% of full scale)
Single-ended voltage ±(0.1% of reading + 0.1% of full scale)
Differential current ±(0.1% of reading + 0.1% of full scale)
Resistance (up to 200 Ω) ±(0.1% of reading + 0.1% of full scale)
Thermistors (up to 130°C) ±(0.15% of reading + 0.1% of full scale)
Pt100/1000 RTD ±(0.15% of reading + 0.1% of full scale)
Differential J, K and N thermocouples (above -50°C) * ±0.1% of full scale
Differential R, S and T thermocouples (above -50°C) * ±0.2% of full scale
Single-ended J, K and N thermocouples (above -50°C) * ±0.15% of full scale
Single-ended R, S and T thermocouples (above -50°C) * ±0.25% of full scale
Pulse count and rate ±(0.0011% of reading +1)
* Includes cold junction compensation (CJC) error. Data logger held at constant temperature
No of Intervals: 4
Data Scaling: Included in standard
OM-SQ software
Data Statistics: Calculated within
OM-SQ-SOFT-PLUS software
Calculated Channels:
Up to 16
Memory Internal:
16 M (1 to 1.8 million readings)
Display/Keypad: 128 x 64 dot
graphical display, 4 button keypad
Power: 2 C cells internal (included),
or external 8 to 28 Vdc via AC
adaptor and USB when plugged in
Battery Life: Up to 5 days with
continuous usage while sampling
all channels once per second
Sensor Power Output: 5 V at
50 mA, external 8 to 28V at 100 mA
(when connected)
Networking: Via RS-232 to
Ethernet adaptor (Model No.
OM-SQ-NET-ADAP)
Modem Support : Via RS-232
modem (GSM modem kit Model
No. OM-SQ-GSM-KIT)