Omega Products OM-CP-PRTRANS-0-30A User Manual

OM-CP-PRTRANS Series Transient Pressure Data Logger
1
4" NPT and Submersible Models
Part of the NOMAD®Family
100 Hz OperationSoftware-Selectable
Trigger
RuggedProgrammable
Start Time
32 Sample
Pre-Trigger Buffer
OM-CP-PRTRANS data logger with 1⁄4 NPT fitting, shown smaller than actual size
It is an all too common paradox: you need to capture transient events at a high sample rate, but the events of interest are erratically spread over a long period. The OM-CP-PRTRANS pressure recorder can solve your problems. It samples up to 100 Hz (10 ms) but it will only trigger on pressure limits that you set beforehand. You can start the trigger on high or low thresholds and end the trigger after either a chosen number of samples, or when the signal crosses over your stop threshold. The device can record up to 255 events and take as many as 262,143 pressure samples. It also shows up to 32 samples of “pre-trigger” data so that you can learn what caused the trigger in the first place. The OM-CP-PRTRANS is a battery operated unit with a standard to your pressure systems. It is also completely submersible and the stainless steel sensor can measure the pressure of most common fluids and gases. The non-volatile memory will retain valuable data even if the user-replaceable battery becomes discharged.
The software converts your PC into a real time strip chart recorder. Data can be printed in graphical or tabular format and can be exported to a text or Microsoft file.
The OM-CP-PRTRANS is your solution to the transient pressure problem.
1
4 NPT for easy coupling
OM-CP-PRTRANS fully submersible data logger, shown smaller than actual size
Specifications
Pressure Sensor:
Semiconductor strain gauge Calibrated Accuracy: 2% FSR,
0.25% @ 25°C typical Pressure Response Time: 0.1 ms (10 to 90% FSR) Repeatability: ±0.5% FSR; ±0.2% typical
Adaptor: 1⁄4 MNPT
or fully submersible Trigger Modes: Software programmable window size of bi-level start/stop triggers
Start Time: Software programmable immediate start time or delay start up to 7 days in advance Real Time Recording: May be used with PC to monitor and record data in real time
Memory: Up to 262,143 samples Number of Events: Up to 255
triggered events
Pre-Trigger Size: Up to 32 samples Recording Interval: 1 reading
every 10 ms to 1 every second Calibration: Digital calibration is available through software Calibration Date: Automatically recorded within device Power: 3.6 V lithium battery (included), user replaceable Battery Life: 3 days continuous @ 10 ms sample rate
E-28
Pressure
Range Resolution 0 to 30 psia 0.02 psia 0 to 100 psia 0.1 psia 0 to 300 psia 0.2 psia 0 to 500 psia 0.5 psia 0 to 1000 psia 1.0 psia 0 to 5000 psia 5.0 psia 0 to 30 psig 0.02 psig 0 to 100 psig 0.1 psig 0 to 300 psig 0.2 psig 0 to 500 psig 0.5 psig
Shelf Life: Up to 1 year when
not in use Data Format: Date and time stamped, psia, psig, inches, feet, mmHg, bar, torr, kPa Computer Interface: PC serial or USB (interface cable required) 115,200 baud
Software:
XP SP3/Vista and 7 (32-bit and 64-bit)
Operating Environment:
-40 to 80°C (-40 to 176°F) 0 to 100% RH non-condensing Dimensions: 163 mm x 32 mm L (6.4 x 1.25")
Weight: 340 g (12 oz) Material: Stainless steel
OM-CP-IFC200 Windows software displays data in graphic or tabular format
MOST POPULAR MODELS HIGHLIGHTED!
To Order
(Specify Model Number)
Model No. Description
OM-CP-PRTRANS-0-30A Transient pressure data logger, 0 to 30 psia, submersible OM-CP-PRTRANS-0-100A Transient pressure data logger, 0 to 100 psia, submersible OM-CP-PRTRANS-0-30G Transient pressure data logger, 0 to 30 psig, submersible OM-CP-PRTRANS-0-100G Transient pressure data logger, 0 to 100 psig, submersible OM-CP-PRTRANS-1-30A Transient pressure data logger, 0 to 30 psia, 1⁄4 NPT OM-CP-PRTRANS-1-100A Transient pressure data logger, 0 to 100 psia, 1⁄4 NPT OM-CP-PRTRANS-1-300A Transient pressure data logger, 0 to 300 psia, 1⁄4 NPT OM-CP-PRTRANS-1-500A Transient pressure data logger, 0 to 500 psia, 1⁄4 NPT OM-CP-PRTRANS-1-1000A Transient pressure data logger, 0 to 1000 psia, 1⁄4 NPT OM-CP-PRTRANS-1-5000A Transient pressure data logger, 0 to 5000 psia, 1⁄4 NPT OM-CP-PRTRANS-1-30G Transient pressure data logger, 0 to 30 psig, 1⁄4 NPT OM-CP-PRTRANS-1-100G Transient pressure data logger, 0 to 100 psig, 1⁄4 NPT OM-CP-PRTRANS-1-300G Transient pressure data logger, 0 to 300 psig, 1⁄4 NPT OM-CP-PRTRANS-1-500G Transient pressure data logger, 0 to 500 psig, 1⁄4 NPT OM-CP-IFC200 Windows software and 1.8 m (6') USB interface cable OM-CP-BAT102 Replacement 3.6 V lithium battery
Operator's manual and USB cable are included with the OM-CP-IFC200 Windows software (software sold separately). Fully submersible data loggers are only available in 0-30 psia, 0-30 psig, 0-100 psia and 0-100 psig ranges. To order data logger with NIST calibration certificate, add suffix “CERT” to model number
Ordering Example: OM-CP-PRTRANS-1-100A-CERT, transient pressure data logger with NIST calibration certificate, 1⁄4 NPT fitting, 0 to 100 psia range and OM-CP-IFC200 Windows software and USB interface cable