Thermocouple Temperature Data Logging System
with Waterproof Enclosure and Remote Probe
OM-CP-ETR101A-KIT
Optional†
TJ36-CASS-18U-6-SMPW-M
thermocouple probe (included).
Many other thermocouple styles
available, contact Sales. **
⻬ Complete System - Includes
Data Logger, Waterproof
NEMA 4 (IP65) Enclosure,
Type K Thermocouple Probe,
USB Interface Cable and
Windows Software
⻬ 10 Year Battery Life
⻬ 1 Second Reading Rate
⻬ Multiple Start/Stop Function
⻬ Ultra High Speed Download
⻬ 500,000 Reading Storage
⻬ Memory Wrap
⻬ Battery Life Indicator
⻬ Optional Password Protection
⻬ Programmable High
and Low Alarms
⻬ Field Upgradeable
OM-CP-ETR101A-KIT,
shown smaller than actual size.
providing maximum data security
even if the battery becomes
discharged. Its small size allows it to
The OM-CP-ETR101A-KIT comes
assembled and includes a data
logger, temperature sensor
(thermocouple Type K), waterproof
NEMA 4 (IP65) enclosure suitable
for outdoor use, USB interface
cable, and software. Setup is fast
and easy.
The OM-CP-ETR101A-KIT is
suitable for a wide range of outdoor
applications including profiling the
exhaust gas temperature of tractor
trailers, buses and trucks. Simply
mount the enclosure containing the
data logger to the vehicle and insert
the included type K thermocouple
probe into the vehicle exhaust pipe
using a compression fitting. The
data logger can then record a
complete exhaust gas temperature
profile that can be used in the
selection of the correct diesel
particulate filter (DPF) for the
vehicle.
Using the included software, the
logger is programmed to record for
a set period. Data is stored in the
data logger, and is downloadable
at any time via a pc or laptop
computer. The storage medium is
non-volatile solid state memory,
† Refer to next page for NIST calibration
ordering information.
1
To Order, Call or Shop Online at omega.com
fit almost anywhere.
Data retrieval is simple. Plug it into
an available USB port and the easy
to use Windows
®
software does the
rest. The software converts your PC
into a real time strip chart recorder.
Data can be printed in tabular
format and can also be exported to
a text or Microsoft Excel®file.
Specifications
INTERNAL CHANNEL
Temperature Range:
-40 to 80°C (-40 to 176°F)
Temperature Resolution:
0.1°C (0.18°F)
Calibrated Accuracy:
±0.25°C (±0.45°F)
REMOTE CHANNEL
Thermocouple Types: K**
Temperature Range:
-270 to 1070°C (-454 to 1958°F)
Accuracy: ±2.0°C (24 AWG wire)
Resolution: 0.1°C
Thermocouple Connection:
Female subminiature (SMP)
connector
Cold Junction Compensation:
Automatic based on internal
channel
Max Thermocouple Resistance:
100 Ω
Reading Rate: 1 reading every
second to 1 every 24 hours
OM-CP-IFC200, Windows software
(included) displays data in graphical
or tabular format.
Memory: 500,000 readings
(software configurable memory
wrap); 250,000 readings in
multiple start/stop mode
or trigger setting mode
Wrap Around: Yes
Start Modes:
• Immediate start
• Delay start up to 18 months
• Multiple pushbutton start/stop
Stop Modes:
• Manual through software
• Timed (sprcific date and time)
Multiple Start/Stop Mode: Start
and stop the device multiple times
without having to download data
or communicate with a PC
**Use of stanless steel braided thermocouple
may allow water to wick in through the cable
and cause damage to the data logger
SM
Multiple Start/Stop Mode
Activation:
To Start the Device:
Press and hold the pushbutton
for 5 seconds, the green LED
will flash during this time. The
device has started logging.
To Stop the Device:
Average battery life
vs. reading rate of
OM-CP-ETR101A-KIT
recording in a 25°C
environment.
Press and hold the pushbutton
for 5 seconds, the red LED will
flash during this time. The device
has stopped logging.
Real Time Recording:
The device may be used with PC to
monitor and record data in real-time
Alarm: Programmable high
and low limits; alarm is activated
when temperature reaches or
exceeds set limits
Alarm Delay: A cumulative alarm
delay may be set in which the
device will activate that alarm
(via LED) only when the device
OM-CP-ETR101A-KIT,
shown smaller than
actual size.
has recorded a user specified time
duration of data
Trigger Settings: High and low
limits may be set for the
thermocouple channel. Once data
meets or exceeds sets limits, the
device will record to memory.
Bi-level start and stop triggers can
also be programmed. Users can
specify the number or readings to
take after the device triggers.
LED Functionality:
Green LED Blinks: 10 second
rate to indicate logging 15 second
rate to indicate delay start mode
Red LED Blinks: 10 second rate
to indicate low battery and/or full
memory 1 second rate to indicate
an alarm condition
Password Protection: An optional
password may be programmed into
the device to restrict access to
configuration options. Data may be
Battery Type: 3.6V lithium battery
(included); user replaceable
Battery Life: 10 years typical at a
15 minute reading rate
Data Format: Date and time
stamped °C, °F, K, °R; μV, mV, V
Time Accuracy: ±1 minute/month
(at 20ºC, stand alone data logging)
Computer Interface:
USB (interface cable required);
115,200 baud
Software: XP SP3/Vista/Windows 7
(32 and 64-bit)
Operating Environment:
-20 to 80ºC (-4 to 176°F),
0 to 100% RH non-condensing
Dimensions:
Data Logger:
36 H x 56 W x 16 mm D
(1.4 x 2.2 x 0.6")
Waterbox:
87 H x 73 W x 27 mm D
(3.5 x 2.9 x 1.1")
Thermocouple Wire:
24 gauge, 762 mm (30")
Thermocouple Probe:
153 L x 3.2 mm dia. (6 x 1⁄8")
Weight:
Complete Kit: 425 g (15 oz)
Waterproof Enclosure,
Data Logger and
Thermocouple: 283 g (10 oz)
read out without the password.
AVAILABLE FOR FAST DELIVERY!
To Order
Model No. Description
OM-CP-ETR101A-KIT Temperature data logging system with waterproof enclosure
OM-CP-ETR101A-KIT-CERT†Temperature data logging system with waterproof enclosure and NIST calibration certificate
OM-CP-BAT105 Replacement 3.6V lithium battery
TJ36-CASS-18U-6-SMPW-M Spare type K thermocouple for OM-CP-ETR101A-KIT data logger [3.2 mm (
SSLK-18-14 316SS compression fitting for (
Comes complete with 3.6 V lithium battery, OM-CP-IFC200 Windows software, 3.7 m (12') USB interface cable, thermocouple probe,
waterproof enclosure and operator’s manual.
Ordering Example: OM-CP-ETR101A-KIT-CERT, temperature data logging system with NIST calibration certificate.
To Order, Call or Shop Online at omega.com
visit omega.com/om-cp-etr101a-kit for pricing and details
ungrounded, 153 mm (6")length, 1 m (40") teflon insulated lead wire,
subminiature male connector]
1
⁄8")
dia thermocouple probe,
1
⁄4" NPT
1
⁄8")
dia,
male connection
SM
2