Omega Products OM-CP-AVS150-5-CERT User Manual

Autoclave Validation System
Part of the NOMAD®Family
Windows software
(included) shows data
in graphical format.
OM-CP-AVS150-CERT Series
Starts at
$
2085
Enables compliance with FDA 21 CFR Part 11
Software Calculates Thermal Resistance in F0
NIST Traceable Calibration Included
Stand Alone, Complete System
No Thermocouple Wires
Digital Calibration Through Software
The OM-CP-AVS150 is a complete system used to perform autoclave validations. The OM-CP-AVS150 consists of a NIST traceable OM-CP-HITEMP-150 data logger, an IP68 extended range thermal shield, an OM-CP-IFC200 USB cable package and FDA 21 CFR part 11 secure software. For larger size autoclaves or mapping projects, the OM-CP-AVS150-5, includes five OM-CP-HITEMP-150’s and five thermal shields.
The OM-CP-HITEMP-150 is completely submersible and can measure temperatures up to 150°C (302°F). The 51 mm (2") rigid probe provides a fast response time and can record readings as fast as once per second.
The OM-CP-HITEMP-150 can be used in each autoclave cycle for verification and to provide data for validation. When used with the thermal shield the device can withstand up to 250°C (482°F) (time dependent).
1
To Order, Call or Shop Online at
Standard
The secure software provides data in graphical and tabular form, and provides a summary and statistical report of the data.
The software also features sterilization calculations to determine the F0 value. Furthermore the software allows for different user levels and logins, electronic signatures, an audit trail and a secure data file to stand up to auditors.
This device can be started and stopped directly from a computer and their compact design allows them to fit almost anywhere.
Data retrieval is simple. Plug the device into an available USB port and our easy-to-use software does the rest. The software converts a PC into a real-time strip chart recorder. Data can be printed in graphical and tabular format or exported to a text or Microsoft®Excel file.
OM-CP-AVS150-CERT, autoclave validation system, $2085, shown smaller than actual size.
All items shown here are included.
OM-CP-HITEMP-150 (included)
shown with protective cover opened.
omega.com
SM
SPECIFICATIONS OM-CP-HITEMP-150 DATA LOGGER
Temperature Sensor:
100 platinum RTD Temperature Range:
-40 to 150ºC (-40 to 212ºF)
Temperature Resolution: 0.05ºC Calibrated Accuracy: ±0.5ºC Start Modes:
Software Programmable
Start now
Delay start Memory: 32,767 readings Reading Rate: One second up
to 12 hours Calibration: Digital calibration
through software Calibration Date: Automatically
recorded within device
Battery Type:
3.9V high-temperature lithium
battery (included) Battery Life: 1 year typical
(1 minute reading rate @25ºC) Data Format: Date and time
stamped ºC, ºF, K, ºR Time Accuracy: ±1 minute/month
at 20ºC (RS232 cable not in use) Computer Interface: PC serial
or USB (interface cable required); 2400 baud
Software: Windows XP SP3/Vista/7 (32 and 64-bit systems)
Operating Environment:
-40 to 150ºC (-40 to 302°F), 0 to 100% RH
Dimensions:
Body: 28 x 45 mm dia.
(1.1 x 1.75") Probe: 50 x 5 mm dia.
3
(2.0 x
16")
Ambient Temperature Temp (150°C / 302°F) Temp (150°C / 302°F)
-200°C (-328°F) 18 min N/A
-180°C (-292°F) 19 min N/A
-160°C (-256°F) 21 min N/A
-140°C (-220°F) 24 min N/A
-120°C (-184°F) 27 min N/A
-100°C (-148°F) 32 min N/A
-80°C (-112°F) 40 min N/A
-60°C (-76°F) 55 min 25 min
-40 to 150°C (-40 to 302°F) Indefinitely Indefinitely 160°C (320°F) 75 min 34 min 170°C (338°F) 63 min 29 min 180°C (356°F) 55 min 26 min 190°C (374°F) 50 min 23 min 200°C (392°F) 45 min 21 min 210°C (410°F) 42 min 19 min 220°C (428°F) 39 min 18 min 230°C (446°F) 36 min 17 min 240°C (464°F) 34 min 16 min 250°C (482°F) 32 min 15 min
Time in Air to Max Internal Time in Liquid to Max Internal
Weight:
OM-CP-HITEMP-150:
225 g (8 oz)
OM-CP-AVS150:
1.72 kg (3.8 lb)
OM-CP-AVS150-5:
3.81 kg (8.4 lb)
Material 316 stainless steel
Specifications
(Thermal Shield) Operating Envionment:
-200 to 250°C (-328 to 482°F) time limited, see table above
IP Rating: IP68 Dimensions: 53.3 H x 66 mm dia
(2.1 X 2.6")
Weight: 0.3 kg (0.65 lb) Material: Teflon
NIST traceable calibration
certificate (included).
AVAILABLE FOR FAST DELIVERY!
To Order
Model No. Price Description
OM-CP-AVS150-CERT $2085 Includes (1) OM-CP-HITEMP-150 data logger with NIST calibration certificate,
. OM-CP-AVS150-5-CERT 4200 Includes (5) OM-CP-HITEMP-150 data loggers with NIST calibration certificates,
Comes complete with 3.9V high temperature lithium battery, NIST calibration certificate, operator’s manual, secure software, and OM-CP-IFC200 interface cable.
Ordering Example: OM-CP-AVS150-CERT, autoclave validation system including a OM-CP-HITEMP-150 data logger, $2085.
To Order, Call or Shop Online at
(Specify Model Number)
an extended range thermal shield, OM-CP-IFC200 interface cable, FDA 21 CFR Part 11 Secure Software and IQ/OQ/PQ validation protocols
(5) extended range thermal shields, OM-CP-IFC200 interface cable, FDA 21 CFR Part 11 Secure Software and IQ/OQ/PQ validation protocols
omega.com