Omega Products OM-80 Installation Manual

omega.com
e-mail: info@omega.com
For latest product manuals:
omegamanual.info
OM-80 SERIES
Miniature RFID Data Loggers
Shop online at
User’s Guide
Servicing North America:
U.S.A.: Omega Engineering, Inc., One Omega Drive, P.O. Box 4047
ISO 9001 Certified Stamford, CT 06907-0047 USA
Toll Free: 1-800-826-6342 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com
Canada: 976 Bergar
Laval (Quebec), H7L 5A1 Canada Toll-Free: 1-800-826-6342 TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca
For immediate technical or application assistance:
U.S.A. and Canada: Sales Service: 1-800-826-6342/1-800-TC-OMEGA
®
Customer Service: 1-800-622-2378/1-800-622-BEST
®
Engineering Service: 1-800-872-9436/1-800-USA-WHEN
®
Mexico/ En Español: 001 (203) 359-7803 FAX: 001 (20) 359-7807 Latin America info@omega.com.mx e-mail: espanol@omega.com
Servicing Europe:
Benelux: Managed by the United Kingdom Office
Toll-Free: 0800 099 3344 TEL: +31 20 347 21 21 FAX: +31 20 643 46 43 e-mail: sales@omegaeng.nl
Czech Republic: Frystatska 184
733 01 Karviná, Czech Republic Toll-Free: 0800-1-66342 TEL: +420-59-6311899 FAX: +420-59-6311114 e-mail: info@omegashop.cz
France: Managed by the United Kingdom Office
Toll-Free: 0800 466 342 TEL: +33 (0) 161 37 29 00 FAX: +33 (0) 130 57 54 27 e-mail: sales@omega.fr
Germany/Austria: Daimlerstrasse 26
D-75392 Deckenpfronn, Germany Toll-Free: 0800 6397678 TEL: +49 (0) 7056 9398-0 FAX: +49 (0) 7056 9398-29 e-mail: info@omega.de
United Kingdom: OMEGA Engineering Ltd.
ISO 9001 Certified One Omega Drive, River Bend Technology Centre, Northbank
Irlam, Manchester M44 5BD United Kingdom Toll-Free: 0800-488-488 TEL: +44 (0) 161 777-6611 FAX: +44 (0) 161 777-6622 e-mail: sales@omega.co.uk
OMEGAnet®Online Service Internet e-mail
omega.com info@omega.com
It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, human applications.
Table of Contents
Section Page
Section 1 Introduction ......................................................................................... 1-1
1.1 Precautions ................................................................................................. 1-1
1.2 Safety Warnings and IEC Symbols ......................................................... 1-2
1.3 Statement on FCC and CE Marking ....................................................... 1-2
1.4 Product Labeling ....................................................................................... 1-3
Section 2 Hardware .............................................................................................. 2-1
2.1 Package Inspection ................................................................................... 2-1
2.2 Included Items ........................................................................................... 2-1
Section 3 Software ................................................................................................ 3-1
3.1 Getting Started ........................................................................................... 3-1
3.2 Software Installation ................................................................................. 3-1
3.3 USB Driver Installation ............................................................................ 3-3
3.4 OM-80 Series Data Logging Software .................................................... 3-6
Section 4 Hardware Installation ........................................................................ 4-1
Section 5 Tag Configuration/Operation ........................................................... 5-1
5.1 Tag Information ......................................................................................... 5-1
5.2 Configuring Tag Settings ......................................................................... 5-3
5.3 Logging Data ............................................................................................. 5-5
5.4 Retrieving Data .......................................................................................... 5-5
Section 6 Calibration ........................................................................................... 6-1
Section 7 Troubleshooting .................................................................................. 7-1
7.1 Tag Troubleshooting ................................................................................. 7-1
7.2 Reader Troubleshooting ........................................................................... 7-1
Section 8 Service ................................................................................................... 8-1
Section 9 Specifications ...................................................................................... 9-1
Section 10 Approvals & Regulatory Compliance .........................................10-1
10.1 FCC (Domestic Use: USA & Canada) ................................................. 10-1
10.2 International Usage & CE Marking (Pending) ................................. 10-1
10.3 CE Declaration of Conformity (DOC) ................................................ 10-1
10.4 ESD Susceptibility ................................................................................. 10-1
i
OM-80 Series Miniature RFID Data Loggers
List of Figures
Section Figure Description .............................................................. Page
Section 1 1-1 IEC Symbols ............................................................... 1-2
1-2 OM-84 Tag Label ....................................................... 1-3
1-3 OM-80-RD1 Reader Top Label ................................ 1-3
1-4 OM-80-RD1 Reader Bottom Label .......................... 1-3
Section 3 3-1 Welcome Screen ......................................................... 3-1
3-2 License Agreement Screen ....................................... 3-2
3-3 Choose Install Location ............................................ 3-2
3-4 Installation Complete Screen ................................... 3-3
3-5 Welcome To The New Found
Hardware Wizard Screen ......................................... 3-4
3-6 Install Software Automatically Wizard Screen ..... 3-5
3-7 Completing The New Found
Hardware Wizard Screen ......................................... 3-5
3-8 Launch Data Logging Software .............................. 3-6
3-9 OM-84 Data Logging Program ................................ 3-7
3-10 Reader Tab .................................................................. 3-8
3-11 Data Display Graph .................................................. 3-9
3-12 Data Display Table .................................................... 3-9
Section 5 5-1 Tag Information Tab .................................................. 5-1
5-2 Tag Settings Tab ......................................................... 5-3
Section 6 6-1 Temperature Calibration Window .......................... 6-1
6-2 Remove Tag Window ............................................... 6-1
6-3 Calibration Complete Window ............................... 6-2
ii
OM-80 Series Miniature RFID Data Loggers
Section 1 - Introduction
Please read this manual completely before unpacking and operating your miniature RFID data logger and reader system. It’s important read and follow all notes, cautions, warnings and safety precautions before operating this device. “Device” referrers to your data logger tag and reader.
Small, simple and affordable, the OM-80 series of data loggers measure and record temperature at a user specified interval ranging from 1 second to over 9 hours. The tag is equipped with a one-button, three-LED user interface. The start/status button can be used to activate the tag or check on the tag's status. Two of the LEDs are used to indicate whether the tag has measured temperatures that exceed programmable upper and lower temperature limits. The third LED is used to indicate the tag's status through a series of blinks.
The tag is configured using a reader and PC user software to operate in one of two modes:
ALARM CLOCK MODE
The tag begins collecting data at a prescribed time.
DELAY MODE
The tag begins collecting data after a specified delay from when the button is pressed.
Once the tag has finished collecting data or in the highly unlikely event that it loses power, the tag must be presented to reader/host software to download the data and re-configure it for another data collection run. The tag can only collect one series of temperature readings at time. The tag cannot be started, then halted and later re-started, without intervention of the host software.
The OM-80 reader/host software requires no programming skills, and enables you to effortlessly select a sample interval, specify a TAG ID, and initiate the start of data collection. The data logger can be configured and ready to use in just moments. In addition, all data can be saved in a format easily compatible with spreadsheet applications such as Microsoft Excel. It is our goal to bring you accurate, low-cost, easy-to-use data loggers that will easily integrate into your working environment. To better serve you and understand your needs, we welcome and appreciate your feedback.
1.1 Precautions
• This device is not designed for use in any medical or nuclear applications.
• Do not operate this device in flammable or explosive environments.
• Never operate with a power source other than the one recommended in this manual.
• Do not operate this device outside of the recommended use outlined in this manual.
There are no user serviceable parts inside your device. Attempting to repair or service your unit may void your warranty:
1-1
Introduction
1
NOTE:
1.2 Safety Warnings and IEC Symbols
This device is marked with international safety and hazard symbols in accordance with IEC standards. It is important to read and follow all precautions and instructions in this manual before operating or commissioning this device as it contains important information relating to safety and EMC. Failure to follow all safety precautions may result in injury and or damage to your device. Use of this device in a manner not specified will void your warranty
IEC Symbols Description
Caution, refer to accompanying documentation
EU’s Waste Electrical and Electronic Equipment Compliance
Figure 1-1 IEC Symbols
OM-80 Series data loggers contain a lithium battery. Do not cut open, incinerate, heat above 85°C, recharge, submerge under water or other liquid or expose the battery to rain or excess humidity. Disposer per local regulations.
1.3 Statement on FCC and CE Marking
1.3.1 FCC Marking
FCC ID: WR3-OM80RD1 IC: 8205A-OM80RD1
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1.) This device may not cause harmful interference. 2.) This device must accept any interference received, including interference that may cause undesired operation.
1.3.2 CE Marking
It is the policy of OMEGA to comply with all worldwide safety and EMI/EMC regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification. For additional information see Section 11 - Approvals & Regulatory Compliance.
Introduction
1
1-2
1.4 Product Labeling
1.4.1 Tag Label
Figure 1-2. OM-84 Tag Label
1.4.2 Reader Labels
Figure 1-3. Reader Top Label OM-80-RD1
Figure 1-4. Reader Bottom Label OM-80-RD1
Introduction
1
1-3
START
HI ALARM
LOW ALARM
OMEGA ENGINEERING INC.
Stamford, Ct 06907
omega.com
Made in U.S.A.
!
Li
Li
CAUTION: Read Accompanying Documentation.
Not For Medical Use.
Range: -40 to 60 C (140 F)
13.56 MHz
STATUS
Contains Lithium Battery. Do not incinerate.
Always dispose of this product in a manner
consistent with local, regional and national
regulations. Do not recharge.
PATENT PENDING
NOMAD
®
RFID TEMPERATURE LOGGER
mini
Model: OM-84-TMP
®
13.56 MHZ
RFID TAG READER
PLACE TAG HERE
OM-80 SERIES
!
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
1) This device may not cause harmful interference;
2) This device must accept any interference received, including interference that may cause undesired operation.
FCC ID: WR3-OM80RD1 IC: 8205A-OM80RD1
OMEGA ENGINEERING, INC. Stamford, CT 06907
Made in U.S.A. omega.com
®
Section 2 - Hardware
It is important that you read this manual completely and follow all safety precautions before operating this instrument.
2.1 Package Inspection
Remove the packing list and verify that you have received all your equipment. If you have any questions about the shipment, please call our Customer Service Department at 1-800-622-2378 or 203-359-1660. We can also be reached on the Internet at omega.com, e-mail: cservice@omega.com. When you receive the shipment, inspect the container and equipment for any signs of damage. Note any evidence of rough handling in transit. Immediately report any damage to the shipping agent.
The carrier will not honor any damage claims unless all shipping material is saved for inspection. After examining and removing contents, save packing material and carton in the event reshipment is necessary.
2.2 Included Items
The following items are supplied in the box.
With kit OM-84-TMP-KIT:
• 5 temperature logging tags with factory replaceable battery
• 1 Benchtop USB tag reader
• 1 User Software CD
• 1 USB cable
• 1 Soft carrying case
• 1 Permanent marker
With kit OM-85-TMP-KIT:
• 5 temperature logging tags in hard plastic case with field replaceable battery
• 1 Benchtop USB tag reader
• 1 User Software CD
• 1 USB cable
• 1 Soft carrying case
• 1 Permanent marker
2-1
Hardware
2
Section 3 – Software
3.1 Getting Started
The following program files are included on the OM-80 Series User Software CD supplied with kit. These files can also be downloaded from the omega.com website should you misplace your CD.
• OM-80 Series Data Logging Program
• OM-80 Series Manual (pdf format)
• OM-80 Series Data Sheet (pdf format)
• OM-80-RD1 USB drivers
3.2 Software Installation
Insert the CD ROM labeled OMEGASOFT®OM-80 Series Data Logging Software into your CD ROM drive. From the Windows Start menu, choose the Run command and type d:\setup into the Open field and click OK. If your CD ROM drive is not the D: drive, use the correct letter in the instructions above. You will then see the welcome window as shown below.
Figure 3-1. Welcome to the Omega Engineering Data Loggin Application Setup Wizard
Click “Next” to continue the installation or “Cancel” to quit. When you click Next the license agreement window will appear.
3-1
Software
3
Figure 3-2. License Agreement
Click “I Agree” to continue the installation or “Cancel” to quit.
Figure 3-3. Choose Install Location
This window allows you to specify a location for the application to be installed. You can click Browse to choose another location or click Install to keep the default location. After you click Install you should see a progress bar and then the completing installation window as shown below. Click Finish to complete the installation.
Software
3
3-2
Loading...
+ 22 hidden pages