Omega Products OL-701-PP User Manual

D-16
Thermistor Probes
Series 700 Linear
Series 700 Linear Response probe assemblies are fitted with precision 44018 linear thermistor elements rated to 100°C (212°F). Each is supplied with 3 m (10') of vinyl covered lead wire. A three (3) conductor phone plug is standard termination. To order longer leads, place an “x” after the model number and specify length up to 76 m (250'). Additional lead lengths are available at $0.80 per 300 mm (12"). Please see Section M.
Thermistor Probes
For Use with Heavy Duty HDX Handle
Laboratory
OL-701-PP General Purpose
Water resistant. Can be buried for sub-soil readings.
OL-709-PP Attachable Surface Temperature Stainless steel cup, epoxy backed. Easy to tape on flat surfaces.
OL-705-PP Air Temperature Stainless steel probe suitable for test rooms, incubators, remote air readings.
OL-706-PP Same as the OL-705-PP, but with an economical plastic housing.
OL-703-PP Tubular Stainless steel probe for rugged duty. Often used for liquid immersion. Immersible only to transition fitting.
OL-710-PP Tubular with Fitting Rugged stainless steel probe with pipe fitting. Suitable for use in pipes or closed vessels.
THX-700 probes are designed to work with the heavy duty HDX handle. Each probe has a 3-prong OTP-copper connector termination and precision 44018 linear thermistor element, rated up to 100°C (212°F), which will work with all readout instruments designed for Series 700 probes, please see Sections L and M.
Quick Disconnect
The General Purpose Probe is for general purpose gas and liquid immersion measurements. Made from a rugged 3.1 mm (
1
8") O.D. 304 stainless steel sheath, 300 mm (12") long, it will adapt to most process applications.
The Penetration Probe easily pierces soft and semi-frozen material as well as soil and sand. Made from a rugged 3.1 mm (1⁄8") O.D. 304 stainless steel sheath, 300 mm (12") long.
The Air Probe is for HVAC applications. The small diameter sheath and radiation hood easily fit into duct-work, grilles, and vents. The probe will work with the OMEGA
®
HDX handle or can be permanently mounted using OMEGALOK
®
compression fittings.
OL-701-PP*
OL-709-PP
OL-705-PP**
OL-703-PP
OL-710-PP
$
54
CUSTOM ASSEMBLIES AVAILABLE!
Series 700 probes are available with other elements for different ranges and in other lengths and configurations. See Section I and contact Custom Engineering for a quotation.
THX-700-GP-12
$
70
Basic Unit
THX-700-NP-12
$
80
Basic Unit
Penetration Probe
THX-700-AP-12
$
90
Basic Unit
*Add suffix “-V” for vinyl tipped version
Phone Plug Connector
ALL MODELS AVAILABLE FOR FAST DELIVERY!
Retractable cable
Aluminum Die Cast Handle
Model
HDX-OTP Series
Handle
$
37
50
General Purpose Probe
Air Probe
D
**For economical plastic version of OL-705-PP,
order Model No. OL-706-PP, $68.
$
75
$
70
$
73
$
63
Heavy Duty HDX Handle
Shown smaller
than actual size
ALL MODELS AVAILABLE
FOR FAST DELIVERY!
D-17
Linear Response Probes Series 700
700 Series Probes are compatible with OMEGA’s, 400 THC and THF Digital Thermometers (please see Section M). To order probes with phone plug termination add “-PP” as a suffix to model number and add $7 to price. 3 m (10') extension cable with phone plug connectors, model ON-EXT-10, $18.
Probes is to provide a complete probe assembly for use with the circuits accepting the 44018 or 44019A thermistor composite.
Series 700 Temperature Probes use the 44018 thermistor composite as the temperature sensor. On special order, probes can also be built with 44019 thermistor composite. The purpose of the Series 700
To Order
(Specify Model Number)
Configuration Model Number Description Price
OL-701
General Purpose. Used for short-term water
and sub-soil readings. Most rugged. probe. $47 Waterproof construction.
OL-701-V
Water resistant, soft, flexible, vinyl tipped version of above model.
OL-702 Small Flexible. Vinyl sheath and tip. Cuvette 127
temperatures. General purpose measurement.
OL-731 General Purpose. Non-immersible, epoxy tipped 107
probe. Can be plotted in place. Probe is suitable for temperature measurement on surfaces.
OL-708 “Banjo” Surface Temperature. Water bath, air 160
surfaces temperatures. Stainless steel.
OL-709 Attachable Surface Temperature. Stainless 56
steel cup, epoxy backed. Easy to tape on flat surfaces. Good for heat loss or compression efficiency study of piping.
OL-729 Small Surface Temperature. Cuvette, water,bath, 137
leaf and other surfaces. 610 mm (24") PFA-covered flexible wire. Stainless steel disc with epoxy back.
OL-705 Air Temperature. Stainless steel probe suitable 66
for test rooms, incubators, remote air readings,
OL-706 monitoring of gas streams. etc. 61
OL-706 has an economical plastic housing.
OL-703 Tubular. Stainless steel probe for rugged duty. 63
Often used for liquid immersion. Probe is immersible only to cap.
OL-704 Tubular-Glass. Chemically inert for liquid 141
immersion use. Thermometric titration. Freezing point determination. Pyrex, 127 mm (5") long.
OL-710 Tubular With Fitting. Rugged, stainless steel 68
probe with pipe fitting. Suitable for taking readings in pipes or inside closed vessels.
1''
330 (13)
5.6
(
7
/32) D
7.9
(5/16) D approx
mm (inches)
7.1
(
9
/32)
4.0
(
5
/32) D
610 (24)
3.2
(
1
/8)
3.2
(
1
/8)
mm (inches)
38 (11/2)
92 (3
5
/8)
2 (
5
/64)
17 Gauge
10.3
(13
/32) D
mm (inches)
11 (7/16) D
3.2 (
1
/8)
mm (inches)
1.6 (1/16)
4.8
(
3
/16) D
610 (24)
3.2 (
1
/8)
mm (inches)
MAX
5.6 (0.220)
13
(
1
/2) D
32
(1
1
/4)
mm (inches)
114 (4 1/2)
3.2 (1/8) D
22.2 (
7
/8)
mm (inches)
4.8 (3/16) D
9
/16
114 (41/2)
3.2 (1/8) D
1
/8 NPT
7.9 (5/16) Max
6.4
(1
/4) Max
3.6 (9/64) D
MOST POPULAR MODELS HIGHLIGHTED!