Omega Products LVUN-600 Installation Manual

Page 1
omega.com
e-mail: info@omega.com
For latest product manuals:
omegamanual.info
Shop online at
User’s Guide
LVUN-600
Non-invasive Ultrasonic Point Level Switches
Page 2
Servicing North America:
U.S.A.: One Omega Drive, P.O. Box 4047
ISO 9001 Certified Stamford, CT 06907-0047
TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com
Canada: 976 Bergar
Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca
For immediate technical or application assistance:
U.S.A. and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA
®
Customer Service: 1-800-622-2378 / 1-800-622-BEST
®
Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN
®
Mexico: En Espan˜ ol: (001) 203-359-7803 e-mail: espanol@omega.com
FAX: (001) 203-359-7807 info@omega.com.mx
Servicing Europe:
Benelux: Postbus 8034, 1180 LA Amstelveen, The Netherlands
TEL: +31 (0)20 3472121 FAX: +31 (0)20 6434643 Toll Free in Benelux: 0800 0993344 e-mail: sales@omegaeng.nl
Czech Republic: Frystatska 184, 733 01 Karviná, Czech Republic
TEL: +420 (0)59 6311899 FAX: +420 (0)59 6311114 Toll Free: 0800-1-66342 e-mail: info@omegashop.cz
France: 11, rue Jacques Cartier, 78280 Guyancourt, France
TEL: +33 (0)1 61 37 2900 FAX: +33 (0)1 30 57 5427 Toll Free in France: 0800 466 342 e-mail: sales@omega.fr
Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
TEL: +49 (0)7056 9398-0 FAX: +49 (0)7056 9398-29 Toll Free in Germany: 0800 639 7678 e-mail: info@omega.de
United Kingdom: One Omega Drive, River Bend Technology Centre
ISO 9002 Certified Northbank, Irlam, Manchester
M44 5BD United Kingdom TEL: +44 (0)161 777 6611 FAX: +44 (0)161 777 6622 Toll Free in United Kingdom: 0800-488-488 e-mail: sales@omega.co.uk
OMEGAnet®Online Service Internet e-mail
omega.com info@omega.com
It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, human applications.
Page 3
UNPACKING INSTRUCTIONS
2
UNPACKING INSTRUCTIONS
Remove the Packing List and verify that you have received all equipment, includ­ing the following (quantities in parentheses):
Ultrasonic Level Switch (1) Operator’s Manual (1) If you have any questions about the shipment, please call the OMEGA Customer
Service Department. When you receive the shipment, inspect the container and equipment for signs of damage. Note any evidence of rough handling in transit. Immediately report any damage to the shipping agent.
Note: The carrier will not honor damage claims unless all shipping material is saved for inspection. After examining and removing contents, save packing material and carton in the event reship­ping is necessary.
For Ultrasonic Point Level Switches LVUN-600 Series
Page 4
TABLE OF CONTENTS
Chapter 1 Point Level Model Description . . . . . . . . . . . . . . . . . . . . . . . . . .4
Chapter 2 Principles of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Chapter 3 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-7
Chapter 4 System Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-9
Chapter 5 Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-11
Page
For Ultrasonic Point Level Switches LVUN-600Series
3
Page 5
SYSTEM DESCRIPTIONS
GENERAL DESCRIPTION
The LVUN-600 Series Liquid Level Detection system is an ideal, low cost ultrasonic liquid level detection system for many applications. It operates in a broad spec­trum of viscous to light liquids.
1
PRINCIPLES OF OPERATION
PRINCIPLES OF OPERATION
The LVUN-600 Series operates using ultrasonic sound wave propagation. Ultrasonic sound waves are greatly attenuated when transmitted thr ough air. Conversely, when liquid is present, transmission of the sound waves is greatly enhanced. The electronic control unit, either integral or r emote to the sensor, generates electrical signals that are converted to bursts of ultrasonic energy at the sensor. The ultra­sonic bursts are transmitted across the liquid sensing gap of the sensor. Upon receipt of a valid signal at the receiver, the solid state electronics generate a “data enable” condition indicating liquid is present. This signal energizes a relay and provides an output condition.
2
4
For Ultrasonic Point Level Switches LVUN-600 Series
Page 6
INST ALLATION
5
GENERAL INSTALLATION
All units are easy to install. The sensor with its remote electr onic control unit can be mounted in any position or orientation desired.
Make sure that all wiring, conduit and electrical fittings confor m to local electrical codes for the location selected.
VISUAL INSPECTION
Unpack the control unit and sensor assemblies. Visually inspect them for any damage. Advise Cosense immediately if either assembly is damaged.
PRELIMINARY OPERATIONAL CHECK
Before installing the unit, a simple operational checkout should be per for med as follows:
WARNING: In a hazardous environment never open the housing cover or con­nect the power leads without first disconnecting the electrical power at its source.
1. Fill a container with liquid.
2. Open the control unit housing cover and connect the power to the control unit (see wiring diagram).
3. Apply power from the source.
4. Place the sensor in the liquid. The r elay should ener gize.
5. Remove the sensor from the liquid. The relay will de-energize indicating that the system is functioning properly.
6. Disconnect the power to the control unit.
7. Proceed to final installation.
NON-INVASIVE / CLAMP-ON TIME
Refer to the typical installation diagram and follow the instructions below.
1. Clean the mounting surface of the pipe or vessel.
2. Coat the sensor faces and the ar ea on the pipe or vessel where sensors are to be mounted liberally with coupling compound (silicone grease or heat sink compound).
3. Clamp the sensor assembly on the pipe or vessel. T ighten the clamp assembly on the vessel until the sensor assembly is firmly mounted against the sensor wall. Do not over tighten.
4. Run the cable to the control unit assembly.
3
For Ultrasonic Point Level Switches LVUN-600Series
Page 7
INST ALLATION
6
CONTROL UNIT
Refer to the typical installation diagram and control unit dimensions when installing the control unit.
CALIBRATION PROCEDURE
After the installation is complete, the system must be calibrated for proper opera-
tion.
1. Connect the sensor cable to electronics as shown in wiring diagram.
2. Connect power as per wiring diagram.
3. Turn the power on.
4. Allow the liquid to rise above the sensing point until the relay is energized.
5. Allow the liquid to fall below the sensing point, relay should de-energized.
6. Repeat steps 4 and 5.
7. Unit is now calibrated. When the liquid level is above the sensing point, the
relay will be energized. When the liquid level is below the sensing point, the relay will be de-energized.
MAINTENANCE
PREVENTIVE MAINTENANCE
Electronics ar e constructed with solid state components. Periodically, check and clean the sensor(s) when used with liquids which cause a coating to build up on the sensor. No other maintenance is requir ed.
CLEANING
If the pipe or vessel to which the sensor is mounted is to be steam cleaned or cleaned with abrasive detergents, remove the entire unit before cleaning by:
1. Disconnecting the power at source.
2. Opening the housing cover.
3
For Ultrasonic Point Level Switches LVUN-600 Series
Page 8
7
3
3. Removing power and control wiring cables.
4. Unthreading the sensor. To reinstall, follow Installation Procedure
SYSTEM MALFUNCTION
Should the system malfunction, notify OMEGA immediately
INST ALLATION
For Ultrasonic Point Level Switches LVUN-600 Series
Page 9
SYSTEM WIRING DIAGRAM
8
WIRING DIAGRAM
Two Channel
4
For Ultrasonic Point Level Switches LVUN-600 Series
Page 10
9
4
SYSTEM WIRING DIAGRAM
WIRING DIAGRAM
Multi Channel:
Four Channel:
Three Channel:
For Ultrasonic Point Level Switches LVUN-600 Series
Page 11
DIMENSIONAL DRAWINGS
10
ENCLOSURE DIMENSIONS
5
For Ultrasonic Point Level Switches LVUN-600 Series
Page 12
5
DIMENSIONAL DRAWINGS
TYPICAL APPLICATION
For Ultrasonic Point Level Switches LVUN-600 Series
11
Page 13
Page 14
Page 15
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
RETURN REQUESTS/INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.
FOR W
ARRANTY RETURNS, please have the
following information available BEFORE contacting OMEGA:
1. Purchase Order number under which the product was PURCHASED,
2. Model and serial number of the product under warranty, and
3. Repair instructions and/or specific problems relative to the product.
FOR NON-WARRANTY REPAIRS,
consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA:
1. Purchase Order number to cover the COST
of the repair,
2. Model and serial number of the product, and
3. Repair instructions and/or specific problems
relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC. © Copyright 2005 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied,
reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.
Page 16
Where Do I Find Everything I Need for
Process Measurement and Control?
OMEGA…Of Course!
Shop online at omega.com
TEMPERATURE
䡺⻬
Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies
䡺⻬
Wire: Thermocouple, RTD & Thermistor
䡺⻬
Calibrators & Ice Point References
䡺⻬
Recorders, Controllers & Process Monitors
䡺⻬
Infrared Pyrometers
PRESSURE, STRAIN AND FORCE
䡺⻬
Transducers & Strain Gages
䡺⻬
Load Cells & Pressure Gages
䡺⻬
Displacement Transducers
䡺⻬
Instrumentation & Accessories
FLOW/LEVEL
䡺⻬
Rotameters, Gas Mass Flowmeters & Flow Computers
䡺⻬
Air Velocity Indicators
䡺⻬
Turbine/Paddlewheel Systems
䡺⻬
Totalizers & Batch Controllers
pH/CONDUCTIVITY
䡺⻬
pH Electrodes, Testers & Accessories
䡺⻬
Benchtop/Laboratory Meters
䡺⻬
Controllers, Calibrators, Simulators & Pumps
䡺⻬
Industrial pH & Conductivity Equipment
DATA ACQUISITION
䡺⻬
Data Acquisition & Engineering Software
䡺⻬
Communications-Based Acquisition Systems
䡺⻬
Plug-in Cards for Apple, IBM & Compatibles
䡺⻬
Datalogging Systems
䡺⻬
Recorders, Printers & Plotters
HEATERS
䡺⻬
Heating Cable
䡺⻬
Cartridge & Strip Heaters
䡺⻬
Immersion & Band Heaters
䡺⻬
Flexible Heaters
䡺⻬
Laboratory Heaters
ENVIRONMENTAL MONITORING AND CONTROL
䡺⻬
Metering & Control Instrumentation
䡺⻬
Refractometers
䡺⻬
Pumps & Tubing
䡺⻬
Air, Soil & Water Monitors
䡺⻬
Industrial Water & Wastewater Treatment
䡺⻬
pH, Conductivity & Dissolved Oxygen Instruments
M-4201/1005
Loading...