NON-CONTACT LOOP POWERED
ULTRASONIC LEVEL TRANSMITTER
LVU800 Series
U Simple, Fast Setup with
Pushbutton Calibration
and LCD Display
U Three Measurement
Ranges Available up to
10 m (32')
U 6-segment LCD Display
Indicates Air Gap or
Liquid Level (Inch or
Centimeter Units)
U 7.6 cm (3") Minimum
Beam Width for
Applications with
Restricted Space
U NEMA 4X (IP65)
Enclosure with Rugged
PVDF Transducer
U Fail-Safe Intelligence with
Diagnostic Feedback for
Easy Troubleshooting
The LVU800 Series general purpose
2-wire ultrasonic transmitter provides
non-contact level measurement up
to 10 m (32'), and is ideally suited for
challenging ultrapure, corrosive or
waste liquids. Pushbutton calibrated,
the transmitter is broadly selected for
atmospheric bulk storage, day tank
and waste sump applications. Media
examples include wastewater and
sodium hydroxide.
SPECIFICATIONS
Range:
LVU809: 10 cm to 3 m (4" to 9.8')
LVU816: 20 cm to 5.5 m
(8" to 18')
LVU826: 20 cm to 8 m
(8" to 26.2')
LVU832: 30 cm to 10 m
(12" to 32.8')
Accuracy: ±0.2% of span
Resolution:
LVU809: 0.5 mm (0.019")
LVU816/826: 1 mm (0.039")
LVU832: 2 mm (0.078")
Beam Width:
LVU809: 5 cm (2")
LVU816/826/832: 7.6 cm
(3") diameter
Deadband:
LVU809: 10 cm (4")
LVU816: 20 cm (8")
LVU826: 20 cm (8")
LVU832: 30 cm (12")
Display Type: LCD, 6-digit
Display Units: Inch, cm or percent
Display Mode: Air gap or liquid height
Memory: Non-volatile
Supply Voltage: 12 to 28 Vdc
Loop Resistance: 500 Ω @ 24 Vdc
Signal Output: 4 to 20 mA, 2-wire
Signal Invert: 4 to 20 mA or 20 to 4 mA
Calibration: Pushbutton
Fail-Safety: Selectable 4 mA,
20 mA, 21 mA, 22 mA or hold
Process Temperature:
-20 to 60°C (-7 to 140°F)
Temperature Compensation:
Automatic
Electronics Temperature:
-40 to 71°C (-40 to 160°F)
Pressure: 30 psi
(2 bar) @ 25°C,
derated @ 1.667 psi
(0.113 bar)
per above 25°C
Enclosure
Rating:
NEMA 4X (IP65)
Enclosure Vent:
Watertight
membrane
Enclosure
Material: PC/ABS FR
Transducer Material:
PVDF
Process Mount:
LVU809: 1 NPT or 1" G
LVU816/826/832: 2 NPT
or 2" G
Mounting Gasket: FKM
Conduit Entrance: Dual,
Classification: General purpose
CE compliance EN 61326 EMC
1
⁄2 NPT
LVU816, shown
smaller than
actual size.
To Order Visit omega.com/lvu800 for Pricing and Details
Model No. Description
LVU809 2-wire transmitter 3 m (9.8') range, display 1 NPT
LVU809-G 2-wire transmitter 3 m (9.8') range, display 1" straight threads
LVU816 2-wire transmitter 5.5 m (18') range, display, 2 NPT
LVU816-G
LVU826 2-wire transmitter 8 m (26.2') range, display, 2 NPT
LVU826-G
LVU832 2-wire transmitter 10 m (32.8') range, display, 2 NPT
LVU832-G
LVM-30 Side mount bracket
Comes complete with operator’s manual.
Ordering Examples: LVU816, 2-wire transmitter 5.5 m (18') range, 2 NPT.
LVU816-G, 2-wire transmitter, 5.5 m (18') range, 2" G connection.
2-wire transmitter 5.5 m (18') range, display, 2" straight threads
2-wire transmitter 8 m (26.2') range, display, 2" straight threads
2-wire transmitter 10 m (32.8') range, display, 2" straight threads