Ultrasonic liqUid level switches
SPECIFICATIONS
Repeatability: 2 mm
(0.08") typical
LVU-230/
260 Series
U 1000:1 Wet-to-Dry Ratio
with 316 SS Machined
Body Sensor
U Epoxy Painted Enclosure
U No Calibration or
Special Installation
Requirements
U AC or 9 to 36 Vdc
Powered Models
U Standard
The LVU-230 and LVU-260 liquid
level switches are the ideal solution
to a host of liquid-level sensing and
control applications. Their small size
and standard 3⁄4 NPT fittings make
them suitable for new or existing
applications. The LVU-230 models
have a relay output along with a
316 SS or PVDF sensor and an
integral miniaturized, encapsulated
electronic control unit mounted in a
cast aluminum, explosion-proof,
watertight enclosure. The LVU-260 is
a 2-wire, 4 or 20 mA output system.
Both use an ultrasonic wave
propagation sensor mounted in the
liquid medium. The electronics
generates a continuous wave
ultrasonic signal that completely
illuminates the liquid-sensing area.
The absence of liquid in the sensing
area causes the ultrasonic signal
to dissipate, which the electronics
senses as a “dry” condition (and
provides a 4 mA output signal in the
LVU-260). When liquid is present,
the amplitude of the ultrasonic signal
increases, indicating a “wet”
condition. This signal is converted by
the electronics and energizes the
10 A relay (LVU-230) or a 20 mA
output signal (LVU-260). The
LVU-230 electronics may be set
to provide the control output to an
alarm, pump, or other device on
either a dry or wet condition.
3
⁄4 NPT Fittings
Delay (On): 0.5 s
Input Power:
LVU-230: 115 Vac 50/60 Hz
standard; 230 Vac 12 Vdc,
or 24 Vdc (optional)
LVU-260: 9 to 36 Vdc
Outputs:
LVU-230: 10 A DPDT
LVU-260: Low-level fail-safe:
4 ±1 mA dry; 20 ±1 mA wet; high
level: 20 ±1 dry, 4 ±1 wet
Dimensions: mm (inch)
96.5
(3.80)
131.6
(5.18)
“A”
ALARM POINT
22.2
(0.88)
38.1
(1.50)
24.1
(0.95)
¾ NPT THREAD
¾ NPT THREAD
STANDARD
MATERIAL
316 SS PVDF
(-40 to 300°F)
Electronics: -29 to 77°C
(-20 to 170°F)
Operating Pressure: Up to 1000 psig
Mounting: 3⁄4 NPT standard
Weight: 453 g (1 lb)
LVU-230S, shown
smaller than
actual size.
Housing: NEMA 4/NEMA 7
watertight, explosion-proof
enclosure, cast aluminum Class I,
Group C and D, Class II, Groups
E, F and G; and Class III, Division
I and 2
Sensor Material:
LVU-230S, LVU-260S: 316 L SS
LVU-230K, LVU-260K: PVDF
Temperature:
Sensor: -40 to 149°C
To Order Visit omega.com/lvu230_260 for Pricing and Details
115 Vac Power 9 to 30 Vdc Power
Model No. Model No. Immersion Length cm (inch) “A”
Stainless Steel
LVU-230S LVU-260S 7.62 (3)
LVU-231S LVU-261S 15.24 (6)
LVU-232S LVU-262S 30.48 (12)
LVU-233S LVU-263S 45.72 (18)
LVU-234S LVU-264S 60.96 (24)
LVU-235S LVU-265S 91.44 (36)
PVDF
LVU-230K LVU-260K 7.62 (3)
LVU-231K LVU-261K 15.24 (6)
LVU-232K LVU-262K 30.48 (12)
LVU-233K LVU-263K 45.72 (18)
LVU-234K LVU-264K 60.96 (24)
LVU-235K LVU-265K 91.44 (36)
Comes complete with operator’s manual. Other materials and lengths (up to 120") available.
Consult OMEGA flow Engineering Department.
For 230 Vac operation, add suffix “-230V” to model number, for additional cost.
For 24 Vdc operation, add suffix “-24V” to model number, no additional cost.
For 12 Vdc operation, add suffix “-12V” to model number, for additional cost.
Ordering Examples: LVU-265S, 316 stainless steel, 2-wire, 4 to 20 mA output sensor,
91.44 cm (36")�sensor immersion length.
LVU-230S, 316 SS sensor with 10 A relay.
K-34
K