Omega Products LVU1501 User Manual

Loop powered and Four-wire uLtrasonic LeveL transmitters
LVU1501 Series
U 0.3 to 7.6 m
(1 to 25') Range
U Exclusive VSS
Sensor Sense
3
U Programmable Zero
and Span Through BCD Switches
U Direct Replacement of
Capacitance System
U Intrinsically Safe and
Explosion Proof Rating with 316LSS Sensor, PTFE, Sensors
U STD Near Zone Varies
from 152.4 to 305 mm (6 to 12")
with
The LVU1500-LP Series Two-Wire (“Four-Wire” for four wire unit), non-contact continuous level transmitter, is easy to program, can be used in hazardous locations, and offers unique stainless steel and ³⁄₄ NPT sensors. It is a great choice for sanitary, hazardous, dirty, corrosive or high purity processes. The 4 to 20 mA output is compatible with all control systems and updates quickly making the LVU1500 Series the right choice for fast filling processes.
The LVU1500 Series is plug-and­play. Digital signal processing, and automatic temperature compensation eliminates all adjustment except zero and span. Zero and span calibration is set directly in inches using digital switches and requires no power. The rugged epoxy coated aluminum enclosure survives where plastic enclosures fail.
K-13
LVU1506-LP (above) and LVU1502-LP (left), shown smaller than actual size.
Operation
The sensor is mounted on the top of the tank. The electronics generate an electronic signal that is converted by the sensor to ultrasonic pulses that are transmitted through air space.
At the liquid/air interface, the pulses are reflected back to the sensor. These echoes are received by the microprocessor in the electronics, which samples the echoes and calculates the level in the tank.
A continous output of 4 to 20 mA (isolated) adjustable in increments of 1"/0.1" over entire span is provided to satisfy a number of applications. Programming is done through a pair of BCD switches.
SPECIFICATIONS
Range: 0.3 to 7.6 m (1 to 25') Output Accuracy: 0.25% of full scale Repeatability: Four Wire: 3.2 mm ( Loop Power:
± 0.13 mm (± 0.005") typical Input Power: Four Wire: 24 Vdc Loop Power: 18 Vdc to 36 Vdc
Two Wire: Loop Power Output Signal:
Four Wire: 4 to 20 mA DC (isolated),
2 to 10 Vdc
Loop Power: 4 to 20 mA DC
Lost Echo Indicator: Four Wire: LED Flashes
Two Wire: LED Flashes and output at 22.0 mA Temperature Compensation: Automatic over full range of sensor operating temperature
1
8") typical
(isolated)
Controls: Programmable zero and span, height & distance-mode through BCD switches increments of 25 mm (1") up to
7.6 m (300"), increments of
2.5 mm (0.1") up to 2.5 m (99.9") Temperature Range: Sensor: -29 to 82°C (-20 to 180°F)
Electronics: -29 to 77°C (-20 to 170°F) Sensor Pressure Rating:
316LSS: 17.2 bar (100 psig) ETFE: Sensor Construction: ETFE or 316 LSS or PTFE Electronics Enclosures: NEMA-4/7 Explosion-Proof: Class I, Divisions 1 or 2 Groups B, C & D, Class II, Divisions 1 and 2, Groups E, F & G, Class III Cenelec
Mounting: NPT and Sanitary: Up to 3 m (10')
2 NPT: Up to 6 m (20')
6.9 bar (40 psig)
3
4"
LVU1506, shown smaller than actual size.
To Order Visit omega.com/lvu1501 for Pricing and Details
Model No. Liquid Range mm (inch) Sensor Length mm (inch) Sensor Mounting Loop Powered
LVU1501-LP 150 to 3000 (5.9 to 118) 254 (10) 316LSS ³⁄₄ NPT LVU1502-LP 150 to 3000 (5.9 to 118) 254 (10) 316LSS Sanitary 1" LVU1503-LP 150 to 3000 (5.9 to 118) 254 (10) 316LSS Sanitary 1¹⁄₂" LVU1504-LP 150 to 3000 (5.9 to 118) 50.8 (2) PTFE ³⁄₄ NPT LVU1505-LP 150 to 3000 (5.9 to 118) 50.8 (2) PTFE Sanitary 1" LVU1506-LP 150 to 3000 (5.9 to 118) 25.4 (1) ETFE ³⁄₄ NPT LVU1508-LP 300 to 7600 (11.8 to 299) 254 (10) 316LSS 2 NPT
Four Wire
LVU1501 150 to 3000 (5.9 to 118) 254 (10) 316LSS ³⁄₄ NPT LVU1502 150 to 3000 (5.9 to 118) 254 (10) 316LSS Sanitary 1" LVU1504 150 to 3000 (5.9 to 118) 50.8 (2) PTFE ³⁄₄ NPT LVU1505 150 to 3000 (5.9 to 118) 50.8 (2) PTFE Sanitary 1" LVU1506 150 to 3000 (5.9 to 118) 25.4 (1) ETFE ³⁄₄ NPT LVU1508 300 to 7600 (11.8 to 299) 254 (10) 316LSS 2 NPT
Accessories
Model No. Description
CNi3233 ¹⁄₃₂ DIN controller, visit omega.com/lvu1501 for more details DPi32 ¹⁄₃₂ DIN panel meter, visit omega.com/lvu1501 for more details 70A-1 Continuous tone alarm PSR-24S 24 Vdc regulated power supply, 90 to 264 Vac supply
Comes complete with operator’s manual.
Ordering Examples: LVU1502-LP, loop powered transmitter with 1" sanitary fitting. LVU1504, four wire transmitter with 3⁄4 NPT fitting.