NON-CONTACT ULTRASONIC
LEVEL TRANSMITTER
LVU100 Series
U Simple Compact Sensor
with Target Calibration
and LED Status
Indicators
U 4 Measurement Ranges
up to 8 m (26') with
1 or 2" (25 to 50 mm)
Transducer Mounting
U 5 cm (2") Minimum Beam
Width for Applications
with Restricted Space
U 5 cm (2") Deadband
Optimizes the Filling
Capacity of Small
Vessels
U PC/ABS Enclosure Rated
NEMA 6 (IP67) with
Optional NEMA 4X (IP65)
U Fail-Safe Intelligence with
Diagnostic Feedback for
Easy Troubleshooting
The LVU100 Series is a general
purpose 2-wire ultrasonic transmitter.
It provides non-contact level
measurement up to 8 m (26'), and
is well suited for handling ultrapure,
corrosive, slurry or waste liquids. The
LVU100 Series transmitter is often
used in atmospheric bulk storage,
day tank, waste sump, process vessel,
IBC tote, 55-gallon drum and waste
sump applications. Media examples
include acetic acid and resin.
SPECIFICATIONS
Range:
LVU104: 5 cm to 1.2 m (2" to 4')
LVU109: 10 cm to 3 m (4" to 9.8')
LVU116: 10 cm to 5 m (4" to 16.4')
LVU126: 20 cm to 8 m (8" to 26.2')
Accuracy:
LVU104: 3 mm (0.125")
LVU109/116/126: ±0.2% of span in air
Resolution:
LVU104/109: 0.5 mm (0.019")
LVU116/126: 1 mm (0.039")
Beam Width:
LVU104/109: 5 cm (2") dia.
LVU116/126: 7.6 cm (3") dia.
Deadband:
LVU104: 5 cm (2")
LVU109/116: 10 cm (4")
LVU126: 20 cm (8")
LED Indication: Power, calibration
and diagnostics
Memory: Non-volatile
Supply Voltage: 12 to 28 Vdc
Loop Resistance: 500 Ω @ 24 Vdc
Signal Output: 4 to 20 mA, 2-wire
Signal Invert: 4 to 20 mA or 20 to 4 mA
Calibration: Target, calibration wire
Fail-Safety: Reverts to 22 mA
Process Temperature: -20 to 60°C
(-4 to 140°F)
Temperature Compensation: Automatic
Electronics Temperature: -40 to 71°C
(-40 to 160°F)
To Order Visit omega.com/lvu100 for Pricing and Details
Model No. Description
LVU104 2-wire transmitter—1.2 m (4') range, 1 NPT, NEMA 6
LVU104G 2-wire transmitter—1.2 m (4') range, 1 straight thread, NEMA 6
LVU109 2-wire transmitter—3 m (9.8') range, 1 NPT, NEMA 6
LVU109G 2-wire transmitter—3 m (9.8') range, 1 straight thread, NEMA 6
LVU116 2-wire transmitter—5 m (16.4') range, 2 NPT, NEMA 6
LVU116G 2-wire transmitter—5 m (16.4') range, 2 straight threads, NEMA 6
LVU126 2-wire transmitter—8 m (26.2') range, 2 NPT, NEMA 6
LVU126G 2-wire transmitter—8 m (26.2') range, 2 straight threads, NEMA 6
LVM-30 Side mount bracket 2 NPT
Comes complete with operator’s manual and 3 m (10') cable.
For NEMA 4X (IP65) rated enclosure add “-NEMA4” to the model number for additional cost.
(cable not included with this model).
Ordering Examples: LVU116, 2-wire transmitter, 5 m (16.4') range, 2 NPT mounting, NEMA 6
(IP67) enclosure with 3 m (10') cable.
LVU104-NEMA4, 2-wire transmitter, 1.2 m (4') range, 1 NPT mounting, optional NEMA 4X
(IP65) enclosure.
K-9
LVU104, shown
smaller than
actual size.
Pressure: 30 psi (2 bar) @ 25°C,
derated @ 1.667 psi (0.115 bar) per °C
above 25°C
Enclosure Rating: NEMA 6 (IP67),
NEMA 4X (IP65) optional
Enclosure Material: PC/ABS FR
Transducer Material: PVDF
Cable Jacket Material: PP
Cable: 3-conductor, shielded 3 m (10')
Conduit Entrance: Dual,
on NEMA 4 (IP65) version
Process Mount:
LVU104/109: 1 NPT or 1" G
LVU116/126: 2 NPT or 2" G
Mounting Gasket: FKM
Classification: General purpose
CE compliance
1
⁄2 NPT