LVE 950-R-NEMA
Electro-Optic Controller
M-5174/1112
Wir ing Con tro lle rs:
Mak e con nec t io ns to s pade t e rm in al s usi n g 1/4 "
fem a le spa d e rece p tac l es pro v ide d .
The open b oard co ntr oll er wit h d ime n si ons an d c on nec tio n i nf or ma ti on i s s ho wn in Figu re 1.
A t ypic a l no rma l l y o pe n (N. O.) ou tp ut wi rin g dia g ra m
wi th A C -po were d a larm is s ho wn i n Fi g ur e 2.
Con dui t Co nne cti ons:
W he n mak i ng c ond u it c onn ect i ons , be s ure t o r emov e P .C . b oa r d as semb l y (f o ur # 6 scr e ws ) f ro m
box b e fo re k no ck ou ts are r e mov e d. T wo siz e s of
con dui t c an be us ed : 7/ 8 " an d 1 - 1/ 8 " di a met e r. C o ndui t c onn ecti o n m ust b e w a ter t ig h t ( i.e . , g aske t
use d) to ma inta in N EMA - 4 X ra ti ng . T w o o f the s ix
con dui t k no ck ou ts are sh ow n i n F i gu re 3 .
Specifications:
Power Input
Voltage Range 115 VAC ±10%
Max. Current Consumption 70 mA
Relay Output (Two (2) Relay Contacts)
N.C. Contact
N.O. Contact
Operating Temp Range:
Output to Sensor:
Pro d uc t mu st be ma i nt aine d an d inst a ll ed i n s tr i ct ac co rd ance wi t h
the O meg a T ec hnic a l bro c hu re and i nst r uc ti on bu lle t in . F ail u re t o
obs erv e t hi s warn i ng c ou l d r e su lt i n se r io us i n jur i es or dama g es .
5 Amp @ 115 VAC - 5 Amp @ 30 VDC
5 Amp @ 115 VAC - 5 Amp @ 30 VDC
-13°F to +158°F (-25°C to +70°C)
12 VDC @ 100 mA; Max.
- W A RNI N G -
Omega
LVE-950-R
NEMA