ULTRASONIC LEVEL TRANSMITTER
100
(3.9)
1 NPT
(1" G
2 NPT
(2 G
optional)
49
(1.9)
138
(5.5)
100
(4)
69
(2.7)
88
(3.4)
133 (5.2)
133 (5.2)
100
(3.9)
62
(2.4)
32
(1.25)
1 NPT
(1" G
optional)
2 NPT
(2 G
optional)
49
(1.9)
138
(5.5)
100
(4)
69
(2.7)
88
(3.4)
133 (5.2)
2 NPT
(2 G
optional)
138
(5.5)
100
(4)
69
(2.7)
88
(3.4)
With PC Programming
OMEGA’s LVU2700 ultrasonic
LVU2700 Series
U 4 Measurement Ranges
from 3 to 10 m (9.8 to 32.8')
U Auto Adaptive Filters
Enable Plug and Play
Operation
U Fast and Easy
Configuration
Via Free Software
Download and
USB Adaptor
U Narrow 5 or 7.6 cm (2 or 3")
Beam Width and Short
10 or 20 cm (4 or 8")
Dead Band
U PVDF Transducer
and NEMA 4X (IP65)
Polycarbonate Enclosure
U Automatic Temperature
Compensation for
Accurate Measurement
Dimensions:
mm (inch)
133
(5.2)
104 (4.1)
96 (3.8)
level transmitter provides
continuous level measurement
up to 10 m (32.8') with a
4 to 20 mA signal output,
and is configured via free
software download and a
USB adaptor. This noncontact liquid level sensor is
ideally suited for corrosive,
ultrapure, sticky or dirty liquids,
and is broadly selected for bulk
storage, day tank, lift stations and
process tank level applications.
SPECIFICATIONS
Range
LVU2710: 10 cm to 3 m (4" to 9.8')
LVU2718: 20 cm to 5.5 m (8" to 18.0')
LVU2726: 20 cm to 8 m (8" to 24.6')
LVU2732: 20 cm to 10 m (8" to 32.8')
Accuracy: ±0.2% of range
Resolution
LVU2710: 0.5 mm (0.019")
LVU2718: 1 mm (0.039")
LVU2726/32: 2 mm (0.079")
Dead Band
LVU2710: 10 cm (4")
LVU2718/26/32: 20 cm (8")
Beam Width
LVU2710: 5 cm (2")
LVU2718/26/32: 7.6 cm (3")
Configuration: USB PC Windows
USB 2.0 Memory: Non-volatile.
The level sensor is configurable via our
free PC software download and USB
adaptor. The sensors are offered with
and without USB connectors. Connectors
can be used to configure any compatible
level product. Download your free copy
at: omega.com/ftp
Supply Voltage: 24 Vdc (loop)
Consumption: 0.5 W
Loop Resistance: 500 Ω @ 24 Vdc
Signal Output: 4 to 20 mA, two-wire
®
Signal Invert: 4 to 20 mA or 20 to 4 mA
Signal Fail-Safe: 4 mA, 20 mA, 21 mA,
22 mA or hold last
Process Temp: -20 to 60ºC
(-4 to 140ºF)
Temp Comp: Automatic
Ambient Temp: -35 to 60ºC
(-31 to 140ºF)
Pressure: Maximum Working
Pressure = 2 bar (30 psi)
Enclosure Rating: NEMA 4X (IP65)
Enclosure Material: Polycarbonate
Trans Material: PVDF
Cable Jacket Material: Polyurethane
Cable Type: 4-conductor, shielded
Process Mount:
LVU2710: 1 NPT (1" G optional)
LVU2718/26/32: 2 NPT (2" G optional)
Mount Gasket: FKM
Classification: General purpose
LVU2710
K
LVU2718/26/32
LVU2710
To Order Visit omega.com/lvu2700 for Pricing and Detail
Model No. Description
LVU2710 Ultrasonic level transmitter with USB connector, range 3 m (9.8')
LVU2718 Ultrasonic level transmitter with USB connector, range 5.5 m (18')
LVU2726 Ultrasonic level transmitter with USB connector, range 8 m (26.2')
LVU2732 Ultrasonic level transmitter with USB connector, range 10 m (32.8')
LVU2710-B* Ultrasonic level transmitter, range 3 m (9.8')
LVU2718-B* Ultrasonic level transmitter, range 5.5 m (18')
LVU2726-B* Ultrasonic level transmitter, range 8 m (26.2')
LVU2732-B* Ultrasonic level transmitter, range 10 m (32.8')
LVCN414-USB
Comes complete with software, mounting gasket and operator’s manual.
For units with G threads add "-G" to model number, for additional cost.
Configuration software for programming available free at omega.com/ftp
Ordering Example: LVU2710, level transmitter with 4 to 20 mA output and USB connector,
1 NPT, 3 m (9.8') range.
USB connector (1 required for -B models, sold separately)*
K-1