Omega Products LVCF-111-12-ETFE User Manual

CONDUCTIVITY LEVEL SWITCHES
LVCR-441-12, $558, shown smaller than actual size.
LVCF/LVCR/LVCP Series
Starts at
$
234
LVCR units with removable rods are available with varied rod lengths for custom applications. Consult Flow Engineering for details. Rods can also be shortened in the field.
LVCN-201 relay, $225,
shown smaller
than actual size.
Easy to Install and OperateRugged ConstructionLow CostRemovable RodsUp to 5 Points of Level
Control
Rods Can be
ECTFE/ETFE Coated
Available with 316 SS
Tri-Grip
TM
Sanitary, Flange, or Threaded Connections Models
LVCF (1-5) Fixed RodsLVCR (1-5) Removable RodsLVCP (1-5) Pendular
Electrodes
CLE-P Pendular Electrode
Without the Housing
LVCN-200 Series Controllers
OMEGA’s conductivity level switches offer a wide range of customized options to meet any application’s needs. They are designed to control the level of all conductive mediums, offering up to 5 different points of level control. Models are available with fixed rigid rods, with removable rigid rods, or with pendular electrodes attached to the housing with cables. These
switches suit applications involving both alarm point detection and on/off pump valve control. Installation is easy and operation is maintenance-free.
The probes work through the variation of the electrical resistance between the reference electrode and the level-control electrode. Conductivity level switches detect the level resistance when their electrodes are covered by the medium.
An electrically conductive tank wall can be used as the reference electrode. If the tank is made of plastic, concrete, or any other non­conductive material, an additional electrode is required as a reference.
The LVCF switches can accommodate up to five 316 SS fixed rods for 5 different levels of control. The rods are isolated with a TFE bushing and can be coated with ECTFE/ETFE when the probe is used with aggressive or sticky media that cause buildup. The user can easily modify operating levels in the tank by cutting the length of the electrodes. The LVCF switches are rugged and compact and have no moving parts. This makes them reliable for controlling conductive media as well as for high-pressure applications.
K-X
LVCF models are compatible with LVCN-200 Series controllers only.
The LVCR models offer the same features as the LVCF, plus removable 316 SS threaded rods that make it possible to switch the rods. Rods can be ordered separately in longer length and can then be custom cut. Removable rods make the system more versatile, easier to handle, and more forgiving if the rod’s length is cut incorrectly.
LVCR models are compatible with LVCN-200 Series controllers only.
Along with the same features as the rigid rod probes, LVCP pendular probes can accommodate up to 5 model CLE-P electrodes. The LVCP probes are ideal for deep measurements in wells or large tanks where long rods would be impractical, but they work equally well for shorter-length applications. The electrodes are suspended from PVC cables that allow for longer lengths, as well as for different applications and installations. LVCP models are compatible with LVCN-200 controllers.
LVCR Mounting Diagram
Minimum and maxium level using an electrode as reference
Minimum and maxium level
1 Level
The electrode model CLE-P is the simplest version of all conductivity probes. A small polypropylene enclosure houses a 316 SS rod that is attached to a PVC cable. This option eliminates the need for a process connection.
LVCN-200 Series conductive liquid on/off level controllers are used to power all level probes. The LVCN­200 models are electronically controlled devices that open and close an electrical contact to effect the operation of other devices in the same, or another, electrical circuit.
The LVCN-201/202 models can control the differential of minimum and maximum level, with an adjustment for sensitivity. The relay has 1 reverse SPDT contact.
The LVCN-203/204 models control 2 independent levels and 2 reverse SPDT contacts. They also include a sensitivity adjustment.
The LVCN-200 Series is designed so that multiple units can be used in combination to provide a variety of control functions, including multiple alarms and on/off control for alternating pumps.
Both models are available with DIN rail sockets or with screws.
SPECIFICATIONS (LVCF/LVCR/LVCP)
Electrical Connection: Cable gland
with ½ NPT conduit Electrodes: Available in configurations
from 1 to 5 electrodes Fixed Rod Length: 100 mm to 2 m
(3.9" to 6.5') Pendular Cable Length: 500 mm
(19.7") to 20 m (65.6') Enclosure: Glass filled nylon or die
cast aluminum; NEMA 4 (IP65) Operating Ambient: -10 to 120°C
(14 to 248°F); 20 bar (290 psi) max
COMMON SPECIFICATIONS (LVCN-200)
Power: 24 Vdc ±10%, 115 or 230 Vac
(50/60 Hz) Sensitivity: 0.5 to 50 k;
potentiometer adjust Operating Ambient: -10 to 60°C
(14 to 140°F) Enclosure: ABS; DIN rail mount or
screw attachment; IP40 protection
K-X
LVCP, shown smaller than actual size. LVCP switches are available with varying cable lengths to monitor and control different fluid levels. Cables may also be shortened by the user. Consult Flow Engineering for details.
LVCP Head
LVCP Probes
K
SPECIFICATIONS (LVCN-201/202)
Application: Min and max
level control
Current: 2 VA max Output: SPDT relay,
5 A @ 250 Vac Time Delay: 0.1 to 5 sec,
adjustable
SPECIFICATIONS (LVCN-203/204)
Application: Control of 2
different levels
Current: 3 VA max Output: Dual SPDT relays,
5 A @ 250 Vac Time Delay: 1 sec, fixed