Omega Products LVCF-111-12-ETFE User Manual

CONDUCTIVITY LEVEL SWITCHES
LVCR-441-12, $558, shown smaller than actual size.
LVCF/LVCR/LVCP Series
Starts at
$
234
LVCR units with removable rods are available with varied rod lengths for custom applications. Consult Flow Engineering for details. Rods can also be shortened in the field.
LVCN-201 relay, $225,
shown smaller
than actual size.
Easy to Install and OperateRugged ConstructionLow CostRemovable RodsUp to 5 Points of Level
Control
Rods Can be
ECTFE/ETFE Coated
Available with 316 SS
Tri-Grip
TM
Sanitary, Flange, or Threaded Connections Models
LVCF (1-5) Fixed RodsLVCR (1-5) Removable RodsLVCP (1-5) Pendular
Electrodes
CLE-P Pendular Electrode
Without the Housing
LVCN-200 Series Controllers
OMEGA’s conductivity level switches offer a wide range of customized options to meet any application’s needs. They are designed to control the level of all conductive mediums, offering up to 5 different points of level control. Models are available with fixed rigid rods, with removable rigid rods, or with pendular electrodes attached to the housing with cables. These
switches suit applications involving both alarm point detection and on/off pump valve control. Installation is easy and operation is maintenance-free.
The probes work through the variation of the electrical resistance between the reference electrode and the level-control electrode. Conductivity level switches detect the level resistance when their electrodes are covered by the medium.
An electrically conductive tank wall can be used as the reference electrode. If the tank is made of plastic, concrete, or any other non­conductive material, an additional electrode is required as a reference.
The LVCF switches can accommodate up to five 316 SS fixed rods for 5 different levels of control. The rods are isolated with a TFE bushing and can be coated with ECTFE/ETFE when the probe is used with aggressive or sticky media that cause buildup. The user can easily modify operating levels in the tank by cutting the length of the electrodes. The LVCF switches are rugged and compact and have no moving parts. This makes them reliable for controlling conductive media as well as for high-pressure applications.
K-X
LVCF models are compatible with LVCN-200 Series controllers only.
The LVCR models offer the same features as the LVCF, plus removable 316 SS threaded rods that make it possible to switch the rods. Rods can be ordered separately in longer length and can then be custom cut. Removable rods make the system more versatile, easier to handle, and more forgiving if the rod’s length is cut incorrectly.
LVCR models are compatible with LVCN-200 Series controllers only.
Along with the same features as the rigid rod probes, LVCP pendular probes can accommodate up to 5 model CLE-P electrodes. The LVCP probes are ideal for deep measurements in wells or large tanks where long rods would be impractical, but they work equally well for shorter-length applications. The electrodes are suspended from PVC cables that allow for longer lengths, as well as for different applications and installations. LVCP models are compatible with LVCN-200 controllers.
LVCR Mounting Diagram
Minimum and maxium level using an electrode as reference
Minimum and maxium level
1 Level
The electrode model CLE-P is the simplest version of all conductivity probes. A small polypropylene enclosure houses a 316 SS rod that is attached to a PVC cable. This option eliminates the need for a process connection.
LVCN-200 Series conductive liquid on/off level controllers are used to power all level probes. The LVCN­200 models are electronically controlled devices that open and close an electrical contact to effect the operation of other devices in the same, or another, electrical circuit.
The LVCN-201/202 models can control the differential of minimum and maximum level, with an adjustment for sensitivity. The relay has 1 reverse SPDT contact.
The LVCN-203/204 models control 2 independent levels and 2 reverse SPDT contacts. They also include a sensitivity adjustment.
The LVCN-200 Series is designed so that multiple units can be used in combination to provide a variety of control functions, including multiple alarms and on/off control for alternating pumps.
Both models are available with DIN rail sockets or with screws.
SPECIFICATIONS (LVCF/LVCR/LVCP)
Electrical Connection: Cable gland
with ½ NPT conduit Electrodes: Available in configurations
from 1 to 5 electrodes Fixed Rod Length: 100 mm to 2 m
(3.9" to 6.5') Pendular Cable Length: 500 mm
(19.7") to 20 m (65.6') Enclosure: Glass filled nylon or die
cast aluminum; NEMA 4 (IP65) Operating Ambient: -10 to 120°C
(14 to 248°F); 20 bar (290 psi) max
COMMON SPECIFICATIONS (LVCN-200)
Power: 24 Vdc ±10%, 115 or 230 Vac
(50/60 Hz) Sensitivity: 0.5 to 50 k;
potentiometer adjust Operating Ambient: -10 to 60°C
(14 to 140°F) Enclosure: ABS; DIN rail mount or
screw attachment; IP40 protection
K-X
LVCP, shown smaller than actual size. LVCP switches are available with varying cable lengths to monitor and control different fluid levels. Cables may also be shortened by the user. Consult Flow Engineering for details.
LVCP Head
LVCP Probes
K
SPECIFICATIONS (LVCN-201/202)
Application: Min and max
level control
Current: 2 VA max Output: SPDT relay,
5 A @ 250 Vac Time Delay: 0.1 to 5 sec,
adjustable
SPECIFICATIONS (LVCN-203/204)
Application: Control of 2
different levels
Current: 3 VA max Output: Dual SPDT relays,
5 A @ 250 Vac Time Delay: 1 sec, fixed
44.5
(1.75)
111.1
(4.375)
82.6
(3.25)
88.9 (3.5)
6.35 (0.25)
63.5
(2.5)
22.3 (0.875)
133.4
(5.25)
LVCF Nylon Head
*
LVCP
LVCF-4
*Aluminum Head is 108 mm (41⁄4")
Dimensions: mm (in) ø = diameter
Application Point level of conductive liquids in tanks and pipes Process
Connection NPT or BSP NPT or BSP NPT or BSP NPT or BSP 2" sanitary
Electrical Cable entry or 1⁄2 NPT conduit entry Electrode 1 fixed rod 2 fixed rods 3 fixed rods 4 fixed rods 5 fixed rods
Length (L) Rod: 100 mm to 2 m (3.9" to 6.56')
Enclosure Material
Temperature -10 to 120°C (14 to 248°F)
Max Pressure 290 psi (20 bar) Class
Protection NEMA 4 (IP65)
LVCN-201, 202
1
2 to 11⁄2
11⁄2" sanitary 11⁄2" sanitary 11⁄2" sanitary 2" sanitary or flange or flange or flange or flange or flange
1 removable rod 2 removable rods 3 removable rods 4 removable rods 5 removable rods 1 pendular 2 pendular 3 pendular 4 pendular 5 pendular
by cable by cable by cable by cable by cable
Cable: 500 mm to 20 m (19.7" to 65.6')
Glass-filled nylon or aluminum die cast
3
4 to 11⁄2 1 to 11⁄2 11⁄2
Front View
LVCR-2
Side View
Inside Head of 3
Rod Controller
Inside Head of 5
Rod Controller
LVCN-203, 204
LVCN-200
Series
Application Control of Min Control of 2 Different
Operating 24 Vdc (±10%) or 24 Vdc (±10%) or Voltage 115 or 230 Vac (50/60 Hz) 115 or 230 Vac (50/60 Hz)
Current Consumption 2 VA 3 VA Sensitivity Adjustment 0.5 to 50 k (potentiometer) 0.5 to 50 k (potentiometer) Output 5 A max, 250 Vac relay (SPDT) 5 A max, 250 Vac relay (2-SPDT) Time Delay 0.1 to 5 seconds 1 second Operating Temperature -10 to 60°C (14 to 140°F) -10 to 60°C (14 to 140°F) Enclosure Material ABS ABS Mounting DIN rail or screws DIN rail or screws Class Protection IP40 IP40
and Max Level for Levels for Conductive
Conductive Level Probes Level Probes
K-X
MOST POPULAR MODELS HIGHLIGHTED!
To Order (Specify Model Number)
Model No. Price Description
LVCF-111-12-ETFE $300 Fixed rod conductivity level switch; one 12" rod,
nylon enclosure, ECTFE/ETFE coating
LVCF-231-24-ETFE 588 Fixed rod conductivity level switch; two 24" rods, 1 NPT process connection,
nylon enclosure, ECTFE/ETFE coating
LVCR-231-60 492 Removable rod conductivity level switch; two 60" rods, 1 NPT process connection,
nylon enclosure
LVCR-341-72 870 Removable rod conductivity level switch; three 72" rods, 1
connection, nylon enclosure
LVCP-121-96 276 Pendular rod conductivity level switch; one electrode, 96" cable,
3
NPT process connection, nylon enclosure
4
LVCP-231-96 348 Pendular rod conductivity level switch; two electrodes, 96" cables,
1 NPT process connection, nylon enclosur
LVCP-341-96 582 Pendular rod conductivity level switch; three electrodes, 96" cables,
1
1
NPT process connection, nylon enclosure
2
Switch Sensors
Model No. Price Description
LVCF-(A)(B)(C)-(D) $198 Custom fixed rod conductivity level switch; select number of rods (A),
LVCR-(A)(B)(C)-(D) 198 Custom removable rod conductivity level switch; Select number of rods
LVCP-(A)(B)(C)-(D) 198 Custom pendular conductivity level switch; Select number of electrodes
process connection (B), enclosure (C) and rod length in inches (D)
(A), process connection (B), enclosure (C) and rod length in inches (D)
(A), process connection (B), enclosure (C) and cable length in inches (D)
Ordering Options
Order Suffix Addl Price Description
A-Rods/Electrodes
1 N/C 1 rod/electrode; single point detection 2 N/C 2 rods/electrodes; min/max detection 3 12 3 rods/electrodes; 3-point detection 4 12 4 rods/electrodes; 4-point detection 5 36 5 rods/electrodes; 5-point detection
B-Process Connection
1 N/C 2 N/C
1
NPT thread (LVCF-1, LVCR-1, LVCP-1 only)
2
3
NPT thread (LVCF/LVCR/LVCP-1 or 2 only)
4
3 N/C 1 NPT thread (LVCF/LVCR/LVCP-1, 2 or 3 only) 4 $150 1 5 186
1
NPT thread (LVCF/LVCR/LVCP-1, 2, 3 or 4 only)
2
1.5" Tri-GripTM, sanitary (LVCF/LVCR-1, 2 or 3 only)
6 300 2" flange, ANSI, 316 SS (all models) 7 210
2" Tri-GripTM, sanitary (LVCF/LVCR-1, 2, 3 or 4 only)
C-Enclosure
1 $6 Glass filled nylon with 2 102 Aluminum die cast with
1
NPT conduit with cable gland
2
1
NPT conduit entry
2
3 108 Aluminum die cast with cable gland entry
D-Rod Length/Cable Length
Specify $30/ft/rod Fixed rod length (in) for LVCF Specify 24/ft/rod Removable rod length (in) for LVCR
+ $24 per rod
Specify
48/electrode + 3/ft
Cable length (in) for LVCP
ETFE Coating
-ETFE $66/ft/rod ECTFE/ETFE coating for LVCF or LVCR rod sensors
Controllers
Model No. Price Description
LVCN-201 $225 Min/max level controller, 24 Vdc power LVCN-202 235 Min/max level controller, 115 Vac power LVCN-202-230VAC LVCN-203 260 LVCN-204 270 LVCN-204-230VAC
Comes complete with operator’s manual. Ordering Examples: LVCF-111-12-ETFE, 1 fixed rod, LVCN-202, controller, 70A-1,
alarm, $300 + 235 + 20 = $555. LVCP-231-96, 2 pendular electrode switch, LVCN-204, controller, 70A-1, alarm, $348 + 270 + 20 = $638.
235
Level controller for 2 independent levels, 230 Vac power Level controller for 2 independent levels, 24 Vdc power Level controller for 2 independent levels, 115 Vac power
270 Min/max level controller, 230 Vac power
K-X
Accessories
Model No. Price Description
70A-1 $20 Continuous tone alarm TX4-100 35 30.5 m (100') spool of
PSU-93 LVCR-(**) 48/ft Replacement rods for
ECLE-P 48 Electrode
Specify rod length (in inches): 12, 24, 36, 60.
**
1
NPT process connection,
2
1
NPT process
2
LVCR-441-12, $558, shown smaller than actual size.
4-conductor wire
40
Unregulated power supply
LVCR Series
K
One Omega Drive | Stamford, CT 06907 | 1-888-TC-OMEGA (1-888-826-6342) | info@omega.com
EPG05
www.omega.com
UNITED KINGDOM
www. omega.co.uk
Manchester, England
0800-488-488
UNITED STATES
www.omega.com
1-800-TC-OMEGA
Stamford, CT.
CANADA
www.omega.ca
Laval(Quebec)
1-800-TC-OMEGA
GERMANY
www.omega.de
Deckenpfronn, Germany
0800-8266342
Karviná, Czech Republic
FRANCE
www.omega.fr
Guyancourt, France
088-466-342
CZECH REPUBLIC
www.omegaeng.cz
596-311-899
BENELUX
www.omega.nl
Amstelveen, NL 0800-099-33-44
More than 100,000 Products Available!
Temperature
Calibrators, Connectors, General Test and Measurement Instruments, Glass Bulb Thermometers, Handheld Instruments for Temperature Measurement, Ice Point References, Indicating Labels, Crayons, Cements and Lacquers, Infrared Temperature Measurement Instruments, Recorders Relative Humidity Measurement Instruments, RTD Probes, Elements and Assemblies, Temperature & Process Meters, Timers and Counters, Temperature and Process Controllers and Power Switching Devices, Thermistor Elements, Probes and Assemblies,Thermocouples Thermowells and Head and Well Assemblies, Transmitters, Wire
Flow and Level
Air Velocity Indicators, Doppler Flowmeters, Level Measurement, Magnetic Flowmeters, Mass Flowmeters, Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area Flowmeters, Vortex Shedding Flowmeters
pH and Conductivity
Conductivity Instrumentation, Dissolved Oxygen Instrumentation, Environmental Instrumentation, pH Electrodes and Instruments, Water and Soil Analysis Instrumentation
Data Acquisition
Auto-Dialers and Alarm Monitoring Systems, Communication Products and Converters, Data Acquisition and Analysis Software, Data Loggers Plug-in Cards, Signal Conditioners, USB, RS232, RS485 and Parallel Port Data Acquisition Systems, Wireless Transmitters and Receivers
Pressure, Strain and Force
Displacement Transducers, Dynamic Measurement Force Sensors, Instrumentation for Pressure and Strain Measurements, Load Cells, Pressure Gauges, Pressure Reference Section, Pressure Switches, Pressure Transducers, Proximity Transducers, Regulators, Strain Gages, Torque Transducers, Valves
Heaters
Band Heaters, Cartridge Heaters, Circulation Heaters, Comfort Heaters, Controllers, Meters and Switching Devices, Flexible Heaters, General Test and Measurement Instruments, Heater Hook-up Wire, Heating Cable Systems, Immersion Heaters, Process Air and Duct, Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters
click here to go to the omega.com home page
Loading...