Omega Products LV3123-48-HT User Manual

CAPACITANCE CONTINUOUS LEVEL MEASUREMENT PROBES
LV3000/4000 Series
Starts at
$
636
LV4021-24, $786,
shown smaller
than actual size.
Can Operate at High
Temperatures and Pressure
Unaffected by
Coating Media
Accurate and Reliable
Measurement
Easy, Economical
Installation
Rugged ConstructionNo Moving PartsCompatible with Both
Conductive and Non-Conductive Media
Wide Range of
Applications/Industries (e.g., Water, Oils, Corrosives)
Sanitary Mount Available
iSeries CNi16D33
controller, $245,
shown smaller than
actual size. Visit
omega.com/cni_series
The LV3000/LV4000 Series continuous level measurement probes are flexible, cost-effective solutions for applications involving liquids, pastes, and some solids. The built-in (one-piece) electronic module provides a 4 to 20 mA output (2-wire) signal that is proportional to the process level. Zero and span adjustment helps account for various media, tank dimensions, rod lengths, and positions of installation.
OMEGA®offers these probes in several different models. The user must choose the probe that suits his or her application and install it in the proper location. When submerged, the probe must be able to produce enough capacitance variance. The probe’s success depends on these important factors:
A) Conductive materials can cause a short circuit between a bare stainless steel probe and the tank wall. For this situation, we recommend using PTFE sleeving on the rod surface.
K-20
B) Material buildup affects the
K
accuracy of RF capacitive measurements. Additional adjustment to the probe’s sensitivity is therefore recommended.
Housings must be compatible with the requirements for hazardous, washdown, wet, or dusty environments. For explosion-proof environments, the housing may need to be certified. In addition, the active probe might need to be intrinsically safe or have an intrinsic safety barrier.
The electronic circuitry of the probe performs several functions, such as rectifying and filtering the incoming power, generating the radio frequency signal, and measuring the changes in current flow.
SPECIFICATIONS (LV3000 SERIES)
Accuracy: 0.5% Repeatability: ±1 mm Level Indication:
Bar graph, 0 to 1000%
Process Connection:
3
1
/
4 to 1
/
2 NPT, Tri-Grip
TM
or flange
Wetted Material: 316 SS or PTFE Enclosure Material: Aluminum die cast Max Pressure: 290 psi (20 bar) Operating Temperature: -10 to 120ºC
(14 to 248ºF)
Class Protection:
LV3000: NEMA 4 (IP65)
LVCN410: IP40 Max Probe Length: 1.8 m (6') Dimensions:
Aluminum Die-Cast Head:
89 W x 108 mm H (3.5 x 4
Diameter of Probe: 16 mm ( Electrical Connection: Cable gland
1
with
/
2 NPT conduit
Note: The LV3000 Series probes require a LVCN400 Series controller.
1
/
4")
5
/
8")
SPECIFICATIONS (LVCN410 SERIES)
Operating Voltage: 24 Vdc, 110 or
240 Vac (50/60 Hz)
Current Consumption: 4 mA Adjustment: Zero and span
(potentiometer) and 2 switch point (potentiometer)
Range of Sensitivity: 50 to 1000 pF Output: 4 to 20 mA and 2-relay SPDT LVCN411/LVCN412:
73 W x 110 H x 110 mm L
7
(2
8 x 43⁄8 x 43⁄8")
SPECIFICATIONS (LV4000 SERIES)
Accuracy: 0.5% Repeatability: ±1 mm Operating Voltage: 12 to 30 Vdc Adjustment:
Zero and span (potentiometer)
Range of Sensitivity: 100 to 5500 pF Frequency Oscillation: 400 kHz Output: 4 to 20 mA (2-wire) Process Connection:
3
1
/
4 to 1
/
2 NPT, Tri-Grip or flange
Wetted Material: 316 SS or PTFE Enclosure Material: Glass-filled nylon
or aluminum die cast
Max Pressure: 290 psi (20 bar) Operating Temperature:
-10 to 120°C (14 to 248°F)
Class Protection: NEMA 4 (IP65) Max Probe Length: 1.8 m (6') Dimensions:
Nylon Head: 89 W x 64 mm H
(3.5 x 2.5")
Aluminum Die-Cast Head:
89 W x 108 mm H (3.5 x 4.25")
Diameter of Probe: 16 mm (
Electrical Connection:
Cable gland with
Note: The LV4000 Series probes require a galvanic isolator, LI-420.
1
/
2 NPT conduit
5
/
8")
SPECIFICATIONS (LI-420)
Input Current from the Evaluation Instrument: 4 to 20 mA
Input Voltage: 22 to 24 Vdc Output Current: 4 to 20 mA Output Voltage to the Transducer
at 20 mA: 12.5 V Output Voltage to the Transducer
at 4 mA: 15.5 V Resistance per Conductor: 15 Testing Voltage:
Input/output circuit: 2000 V
Domestic Current Demand:
300 ±60 µA
Ambient Temperature:
-20 to 70°C (-4 to 158°F)
Enclosure Dimensions:
44 W x 82 H x 110 mm L
3
1
/
4 x 4
3
/
8")
(1
/
4 x 3
eff
LI-420, $390, shown actual size.
LV4121-36, $1056, shown smaller than actual size.
K-21
Loading...
+ 2 hidden pages