CAPACITANCE CONTINUOUS
LEVEL MEASUREMENT
PROBES
LV3000/4000 Series
Starts at
$
636
LV4021-24, $786,
shown smaller
than actual size.
Can Operate at High
Temperatures and
Pressure
Unaffected by
Coating Media
Accurate and Reliable
Measurement
Easy, Economical
Installation
Rugged Construction
No Moving Parts
Compatible with Both
Conductive and
Non-Conductive Media
Wide Range of
Applications/Industries
(e.g., Water, Oils,
Corrosives)
Sanitary Mount
Available
iSeries CNi16D33
controller, $245,
shown smaller than
actual size. Visit
omega.com/cni_series
The LV3000/LV4000 Series
continuous level measurement
probes are flexible, cost-effective
solutions for applications involving
liquids, pastes, and some solids.
The built-in (one-piece) electronic
module provides a 4 to 20 mA
output (2-wire) signal that is
proportional to the process level.
Zero and span adjustment helps
account for various media, tank
dimensions, rod lengths, and
positions of installation.
OMEGA®offers these probes in
several different models. The user
must choose the probe that suits
his or her application and install it
in the proper location. When
submerged, the probe must be able
to produce enough capacitance
variance. The probe’s success
depends on these important factors:
A) Conductive materials can cause
a short circuit between a bare
stainless steel probe and the
tank wall. For this situation, we
recommend using PTFE sleeving
on the rod surface.
K-20
B) Material buildup affects the
K
accuracy of RF capacitive
measurements. Additional
adjustment to the probe’s sensitivity
is therefore recommended.
Housings must be compatible with
the requirements for hazardous,
washdown, wet, or dusty
environments. For explosion-proof
environments, the housing may
need to be certified. In addition, the
active probe might need to be
intrinsically safe or have an intrinsic
safety barrier.
The electronic circuitry of the probe
performs several functions, such as
rectifying and filtering the incoming
power, generating the radio
frequency signal, and measuring
the changes in current flow.
SPECIFICATIONS
(LV3000 SERIES)
Accuracy: 0.5%
Repeatability: ±1 mm
Level Indication:
Bar graph, 0 to 1000%
Process Connection:
3
1
/
4 to 1
/
2 NPT, Tri-Grip
TM
or flange
Wetted Material: 316 SS or PTFE
Enclosure Material: Aluminum die cast
Max Pressure: 290 psi (20 bar)
Operating Temperature: -10 to 120ºC
(14 to 248ºF)
Class Protection:
LV3000: NEMA 4 (IP65)
LVCN410: IP40
Max Probe Length: 1.8 m (6')
Dimensions:
Aluminum Die-Cast Head:
89 W x 108 mm H (3.5 x 4
Diameter of Probe: 16 mm (
Electrical Connection: Cable gland
1
with
/
2 NPT conduit
Note: The LV3000 Series probes require a
LVCN400 Series controller.
1
/
4")
5
/
8")
SPECIFICATIONS
(LVCN410 SERIES)
Operating Voltage: 24 Vdc, 110 or
240 Vac (50/60 Hz)
Current Consumption: 4 mA
Adjustment: Zero and span
(potentiometer) and 2 switch point
(potentiometer)
Range of Sensitivity: 50 to 1000 pF
Output: 4 to 20 mA and 2-relay SPDT
LVCN411/LVCN412:
73 W x 110 H x 110 mm L
7
(2
⁄8 x 43⁄8 x 43⁄8")
SPECIFICATIONS
(LV4000 SERIES)
Accuracy: 0.5%
Repeatability: ±1 mm
Operating Voltage: 12 to 30 Vdc
Adjustment:
Zero and span (potentiometer)
Range of Sensitivity: 100 to 5500 pF
Frequency Oscillation: 400 kHz
Output: 4 to 20 mA (2-wire)
Process Connection:
3
1
/
4 to 1
/
2 NPT, Tri-Grip or flange
Wetted Material: 316 SS or PTFE
Enclosure Material: Glass-filled nylon
or aluminum die cast
Max Pressure: 290 psi (20 bar)
Operating Temperature:
-10 to 120°C (14 to 248°F)
Class Protection: NEMA 4 (IP65)
Max Probe Length: 1.8 m (6')
Dimensions:
Nylon Head: 89 W x 64 mm H
(3.5 x 2.5")
Aluminum Die-Cast Head:
89 W x 108 mm H (3.5 x 4.25")
Diameter of Probe: 16 mm (
Electrical Connection:
Cable gland with
Note: The LV4000 Series probes require a
galvanic isolator, LI-420.
1
/
2 NPT conduit
5
/
8")
SPECIFICATIONS
(LI-420)
Input Current from the Evaluation
Instrument: 4 to 20 mA
Input Voltage: 22 to 24 Vdc
Output Current: 4 to 20 mA
Output Voltage to the Transducer
at 20 mA: 12.5 V
Output Voltage to the Transducer
at 4 mA: 15.5 V
Resistance per Conductor: 15 Ω
Testing Voltage:
Input/output circuit: 2000 V
Domestic Current Demand:
300 ±60 µA
Ambient Temperature:
-20 to 70°C (-4 to 158°F)
Enclosure Dimensions:
44 W x 82 H x 110 mm L
3
1
/
4 x 4
3
/
8")
(1
/
4 x 3
eff
LI-420, $390, shown
actual size.
LV4121-36, $1056, shown
smaller than actual size.
K-21