Omega Products LV141 User Manual

UNIVERSAL LIQUID-LEVEL SENSOR
Hermetically Sealed Magnetic Reed Switch
Permanent Magnet
Float
S
SN
N
S
Magnet
Reed
Switch
Glass
Envelope
N
LV 1 4 0
LV 1 4 0
LV141, $105, shown larger
LV140 Series
Starts at
than actual size.
$
105
Steel Double-Wall Tanks,
Containment Sump,
and Piping Sump Applications
Compact—Fits Interstitial
Spaces
Suitable for
No Calibration NecessaryLong Service Life
The compact LV140 single-float, liquid-level sensor is ideal for use in steel double-wall tanks or containment sump areas. It requires no calibration, and is easy to install and maintain. When positioned vertically at the bottom of a steel tank’s stand pipe or in a sump, it detects liquids such as hydrocarbons and water, as low as 3⁄4" from the bottom of a tank or sump. The epoxy-encapsulated design is ideal for harsh environments. An integral slosh shield guards the float from debris.
The principle behind the LV140 is straightforward. The float is equipped with powerful, permanent magnets. As the float rises or lowers with liquid level, it actuates a magnetic reed switch mounted within the stem. In response, the electrical circuit opens or closes, activating an external alarm or control circuit. When mounted vertically, the LV140 provides a consistent accuracy of ±1⁄8".
The reed switch ensures long, trouble-free service. Hermetically sealed, these switches allow for repeatability, with actuation points that remain constant over the life of the unit.
Note: The LV140 sensor is a non-voltage­producing device and does not contain energy-storing components. However, since primary use is in hazardous locations, an appropriate intrinsically safe (IS) interface device is required for its use.
K-97
Sealing Nut
Liquid Tight Fitting
Slosh Shield
36.5
(1-7/16) REF
88.9
(3-1/2) REF
Cable
Float
Retaining
Ring
19.0 (3/4)
Actuation
Retaining ring
Non-Isolated
No Dry
or
NC Dry
Isolated
No Dry
or
NC Dry
Single IS Relay
No Dry
or
NC Dry
Note: If 2 signal lines must be maintained at above ground potential,
Shield
Float
exploded view.
Typical Wiring Diagram
Hazardous
Area
Black
Red
2-Conductor
Cable
Hazardous
Area
Black
Red
2-Conductor
Cable
Hazardous
Area
Black
Red
2-Conductor
Cable
an individual zener barrier is required per single line.
Non-Hazardous
Area
Zener
Barrier
Non-Hazardous
Area
Supply Zener Barrier
3
3
2 1
2 1
Signal Return
Zener Barrier
Non-Hazardous
Area
Load
Intrinsically-Safe Relay
Fuse*
Fuse*
LV141, $105,
DC
power
supply
annunc.
Sence
Resistor
DC
power
supply
annunc.
Fuse
Fuse
K-98
Hot Vac
Neutral
Vac
Dimensions: mm (in)
SPECIFICATIONS
Wetted Materials: Brass, Buna, nylon,
PVC, beryllium, copper
Operating Temperature:
-40 to 110°C (-40 to 230°F)
Water: Up to 82.2ºC (180ºF)
Accuracy: ±3.2 mm (
1
8")
Switch Rating: 20 VA, 120 to 240 Vac pilot duty; 20 W, 50 to 240 Vdc resistive
Cable: 2-conductor PVC or PFA coated jackets [7.6 m (25') extended]
Weight: 453 g (1 lb)
MOST POPULAR
MODEL HIGHLIGHTED!
To Order
(Specify Model Number)
Model No. Price Cable
LV141 $105 PVC jacketed,
LV142 180 PFA jacketed
Comes complete with 7.6 m (25'), 2-conductor PVC or PFA jacketed cables and operator’s manual. For normally open switch add suffix “-NO” at the end of the part number; no extra cost.
Ordering Example: LV142, PFA jacketed sensor, $180.
level sensor normally closed, dry
level sensor normally closed, dry
K
Loading...
+ 1 hidden pages