Omega Products LDP63000 Installation Manual

User’s Guide
LLDDPP6633000000
Large DDisplay MMeter
Shop online at
omega.com
e-mail: info@omega.com
For latest product manuals:
omegamanual.info
OMEGAnet®Online Service
omega.com
Internet e-mail
info@omega.com
Servicing North America:
U.S.A.: One Omega Drive, P.O. Box 4047
ISO 9001 Certified Stamford, CT 06907-0047
TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com
Canada: 976 Bergar
Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca
For immediate technical or application assistance:
U.S.A. and Canada: Sales Service: 1-800-826-6342/1-800-TC-OMEGA
®
Customer Service: 1-800-622-2378/1-800-622-BEST
®
Engineering Service: 1-800-872-9436/1-800-USA-WHEN
®
Mexico: En Español: (001) 203-359-7803 e-mail: espanol@omega.com
FAX: (001) 203-359-7807 info@omega.com.mx
Servicing Europe:
Czech Republic: Frystatska 184, 733 01 Karviná, Czech Republic
TEL: +420 (0)59 6311899 FAX: +420 (0)59 6311114 Toll Free: 0800-1-66342 e-mail: info@omegashop.cz
Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
TEL: +49 (0)7056 9398-0 FAX: +49 (0)7056 9398-29 Toll Free in Germany: 0800 639 7678 e-mail: info@omega.de
United Kingdom: One Omega Drive, River Bend Technology Centre
ISO 9002 Certified Northbank, Irlam, Manchester
M44 5BD United Kingdom TEL: +44 (0)161 777 6611 FAX: +44 (0)161 777 6622 Toll Free in United Kingdom: 0800-488-488 e-mail: sales@omega.co.uk
It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.
WARNING : These products are not designed for use in, and should not be used for, human applications.
3
z LARGE LED DISPLAY READABLE TO 70 FEET z VARIOUS ANALOG INPUT MODULES;
DC VOLTAGE AND CURRENT PROCESS SIGNALS TRUE RMS VOLTAGE AND CURRENT THERMOCOUPLE OR RTD
z ALARMS, ANALOG OUTPUT, AND COMMUNICA TION z CUSTOM UNITS LABEL WITH BACKLIGHT z PROGRAMMABLE USER INPUTS z PROGRAMMABLE FUNCTION KEYS z UNIVERSAL AC/DC POWERED MODELS z PROGRAMMING SOFTWARE z NEMA 4/IP65 z FIELD INSTALLABLE OUTPUT CARDS (Optional)
SAFETY SUMMARY
All safety regulations, local codes and instructions that appear in this and corresponding literature, or on equipment, must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it. If equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
The protective conductor terminal is bonded to conductive parts of the
equipment for safety purposes and must be connected to an external protective earthing system.
SPECIFICATIONS
Input specifications, wiring, and programming information is contained in the corresponding literature.
1. DISPLAY: 1.5" (38 mm) Red LED
5-Digit: (-19999 to 99999)
2. POWER REQUIREMENTS:
AC Modules: 85 to 250 VAC, 50/60 Hz, 18 VA DC Modules: 11 to 36 VDC or 24 VAC ±10%, 50/60 Hz, 14 W
3. ANNUNCIATORS: MAX, MIN, TOT, SP1, SP2, SP3, and SP4
Optional units label with backlight
4. KEYPAD: Five tactile membrane switches integrated into the front panel
5. CERTIFICA TIONS AND COMPLIANCES:
UL Recognized Component, File #E313607, UL61010A-1, CSA22.2 No. 1010-1
Recognized to US and Canadian requirements under the Component Recognition Program of Underwriters Laboratories, Inc.
UL Listed, File # E313547, UL508, CSA C22.2 No. 14-M95
LISTED by Und. Lab. Inc. to U.S. and Canadian safety standards
Type 4 Enclosure rating (Face only), UL50
IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment
for measurement, control, and laboratory use, Part 1.
IP65 Enclosure rating (Face only), IEC 529
ELECTROMAGNETIC COMPATIBILITY
EMC specifications determined by the input module type.
DIMENSIONS In inches (mm)
CAUTION: Risk of Danger.
Read complete instructions prior to
installation and operation of the unit.
CAUTION: Risk of electric shock.
PANEL CUT-OUT
C
US LISTED
U
L
R
IND. CONT. EQ.
51EB
GENERAL DESCRIPTION
The LDP63000 Display is a versatile display that can increase productivity by offering the plant floor or production area a large visual display of their current status. Whether your measurement is temperature, weight, or flow, the LDP63000 can satisfy your requirement. With the use of a units label and backlighting, the display can be tailored to show the actual engineering unit, which further enhances the display. The LDP63000 display accepts various analog inputs through the use of input modules which allow the unit to adapt to most any application. Additional plug-in option cards can add alarms, analog output, and communication/bus capabilities, making the LDP63000 a truly Intelligent Panel Meter.