Omega Products LD400-2.5 User Manual

MINIATURE DC OUTPUT LVDT DISPLACEMENT TRANSDUCERS
WITH ACETAL BEARINGS
±1 to ±5 mm (±0.04 to ±0.20")
LD400 Series
U High-Output Miniature
Transducers
U Acetal Bearings for
Precise Motion
U Infinite Resolution U Rugged, Low-Mass
Construction
U Compatible with
Standard DC Signal
U Conditioning
Modules and Instruments
The LD400 Series miniature DC to DC transducers can measure displacements up to ±5 mm (±0.20") with very high accuracy and infinite resolution. Their free-guided armature incorporates acetal bearings, which provide near-frictionless motion to detect the smallest movement the associated instrumentation is capable of identifying.
These transducers use a precision linear variable differential transformer as the measuring source, along with hybrid ICs, including an oscillator, demodulator, and filter. Together, they make up a self-contained unit that accepts DC input and provides DC output relative to armature position. The unit’s high linearity and low mass of moving parts are ideal for applications in civil, mechanical, chemical, and production engineering.
SPECIFICATIONS
ELECTRICAL
Linearity: 0.3% FS Sensitivity: (mV/V/mm) see chart below
(actual output supplied with each unit)
Excitation: 10 to 24 Vdc regulated Energizing Current at 10 Vdc:
LD400-1, 10 mA; LD400-25, 10 mA; LD400-5, 13 mA
Response Time: LD400-1 and LD400-2.5 = 5 ms; LD400-5 = 3 ms
Frequency Response: 50 Hz for -3 dB Ripple: <1% FS Thermal Effect: Zero: LD400-1 <0.02%
FS/°C; LD400-2.5 and LD400-5 <0.01% FC/°C; sensitivity: <0.025% FC/°C
Compensated Temperature Range:
-20 to 80°C (-4 to 176°F) Operating Temperature Range:
-20 to 80°C (-4 to 176°F)
To Order Visit omega.com/ld400 for Pricing and Details
MODEL NO.
LD400-1 ±1.0 mm (0.06") 75 mV/V/mm DP41-S, DP25B-S LD400-2.5 ±2.5 mm (0.10") 75 mV/V/mm DP41-S, DP25B-S LD400-5 ±5.0 mm (0.20") 54 mV/V/mm DP41-S, DP25B-S
Ordering Example: LD400-5, stroke of ±5 mm.
STROKE
SENSITIVITY COMPATIBLE METERS
LD400-5, shown actual size.
Electrical Connection: 2.9 m (9')
shielded, color-coded cable Sensitivity and Linearity Data:
Provided with a transducer output impedance of 2.4 kΩ into a calibration load of 20 kΩ at 20°C (68°F); variations in these parameters will change performance
MECHANICAL
Threaded Core: M2 thread Core Material: Ni/Fe—Radio Metal 50 Case Material:
400 Series stainless steel
Weight: See chart on next page
CONNECTIONS
Electrical Connections: Red: + Excitation
Blue: – Excitation White: + Signal* Green: – Signal Yellow: No connection
White and red in phase for positive
*
inward displacement.
J-11
MINIATURE DC DISPLACEMENT TRANSDUCERS
LD400 LINE ART
3
(0.12)
DP25B-S.
B
19 (0.75)
DP41-S.
Both meters shown slightly smaller than actual size.
LD400-5, shown actual size.
COMPATIBLE INSTRUMENTS, VISIT OMEGA.COM
MODEL NO. DESCRIPTION
DP25B-S Ratiometric voltage and current input meter with excitation DP41-S 115 Vac powered strain gage indicator
A
(0.14) CABLE
3.5
M2X6
6.0
(0.24)
10
(0.39)
Dimensions: mm (inch)
1 (0.04)
1.9
(0.074)
DISPLACEMENT
J
CORE
ASSEMBLY
Wiring : Red = + Supply Blue = - Supply White = + Signal Green = - Signal Yellow = N/A
MODEL NO. mm (inch) A B BODY CORE (GUIDED)
LD400-1 ±1.0 (0.04) 21.5 (0.85) 37 (1.46) 26 (1.02) 1.0 (0.04) LD400-2.5 ±2.5 (0.10) 21.5 (0.85) 37 (1.46) 26 (1.02) 1.0 (0.04) LD400-5 ±5.0 (0.20) 20.5 (0.81) 43 (1.69) 30 (1.18) 1.2 (0.04)
* At electrical zero.
LINEAR STROKE DIMENSIONS*: mm (inch) WEIGHT g (oz)