Omega Products LCWD-10K Installation Manual

NOTE:
DESCRIPTION
The OMEGA®LCWD Series Load Cell is a compact design with a full Wheatstone Bridge. Typical applications include Clamping Forces, Die Loads, Bolt Stresses, Weighing Systems, and Structural Loads.
The load washer can be used as a washer, sensing compression force, or a compression load cell. When utilized as a compression load cell, the load buttons supplied should be used. If the height of the buttons provided is too restrictive, you can use one or none of the buttons. When you are using less than 2 buttons, be sure that the active ridge (inside) of the washer is seated on a flat surface that transmits the load. Whenever possible, the buttons provided should be used because they insure correct loading.
When used as a washer load cell, the set of spherical washers should be used as a washer cell, the set of spherical washers should be used on one side of the load cell and a flat washer (not provided) on the other side of the washer. When choosing a flat washer, make sure that the inner diameter of the flat washer is less than the diameter of the inner ring of the load washer to insure that the active ridge is seated on the flat washer.
The following load cell types are available from OMEGA Engineering:
Dimensions in Inches (mm)
UNPACKING
Remove the Packing list and verify that all equipment has been received. If there are any questions about the shipment, please call OMEGA Customer Service Department.
Upon receipt of shipment, inspect the container and equipment for any signs of damage. Take particular note of any evidence of rough handling in transit. Immediately report any damage to the shipping agent.
The carrier will not honor any claims unless all shipping material is saved for examination. After examining and removing contents, save packing material and carton in the event reshipment is necessary.
LOAD CELL SPHERICAL WASHERS
Part Rated Part Bore H of Bolt
Number Capacity Weight Bore O. D. H Number Size Button Size
LCWD-200 200 lb 1.0 lb 0.40 (10) 1.00 (25) 0.35 (9.0) SPW-2 0.35 (8.9) 0.37 (9.4) 5/16 (7.9)
LCWD-500 500 lb 1.0 lb 0.40 (10) 1.00 (25) 0.35 (9.0) SPW-2 0.35 (8.9) 0.42 (10.7) 5/16 (7.9)
LCWD-1K 1,000 lb 1.0 lb 0.40 (10) 1.00 (25) 0.35 (9.0) SPW-2 0.35 (8.9) 0.55 (14.0) 5/16 (7.9)
LCWD-2K 2,000 lb 1.0 lb 0.40 (10) 1.00 (25) 0.35 (9.0) SPW-2 0.35 (8.9) 0.55 (14.0) 5/16 (7.9)
LCWD-5K 5,000 lb 1.0 lb 0.40 (10) 1.00 (25) 0.35 (9.0) SPW-2 0.35 (8.9) 0.55 (14.0) 5/16 (7.9)
LCWD-10K 10,000 lb 1.0 lb 0.40 (10) 1.00 (25) 0.35 (9.0) SPW-2 0.35 (8.9) 0.55 (14.0) 5/16 (7.9)
LCWD-20K 20,000 lb 1.5 lb 0.50 (13) 1.20 (30) 0.40 (10) SPW-3 0.41 (10.3) 0.76 (19.3) 3/8 (9.5)
LCWD-50K 50,000 lb 2.0 lb 0.76 (19) 1.75 (44) 0.50 (13) SPW-5 0.66 (16.7) 1.0 (25.4) 5/8 (15.9)
LCWD-100K 100,000 lb 3.0 lb 1.01 (26) 2.25 (57) 0.70 (18) SPW-7 0.94 (23.8) 1.5 (38.0) 7/8 (22.2)
LCWD-200K 200.000 lb 6.0 lb 1.51 (39) 3.00 (77) 1.25 (32) SPW-7 0.94 (23.8) 2.0 (50.8) 7/8 (22.2)
Cautionary Notes for Safe Product Use.
WARNING! This symbol in this manual indicates a potential danger or hazard capable of
resulting in a serious injury or loss of life.
LCWD Series
Load Washer & Compression Load Cells
INSTRUCTION
SHEET
M1131/0509
Shop online at: omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info
O.D.
I.D.
H
BLACK -EXC GREEN +OUT WHITE -OUT
CABLE
HOW LOAD CELLS WORK
Load cells have an output or sensitivity in mV/V. What this sensitivity/output represents is as follows:
Change in millivolt output from zero load to the full scale capacity of the load cell (21.3 mV in this example)
No load cell has exactly zero millivolts at no load. Most cells have a small millivolt DC offset of a few millivolts which is normal. To scale a system the end user just scales his recorder/meter for a full scale change of (21.3 mV per example), and connects the load cell in a no load situation and rezeros the pens/display for a correct zero reading.
DIMENSIONS
INSTALLATION SCHEMATIC
WIRING DIAGRAM
TYPICAL EXAMPLE
RADIUS
BUTTON
LOAD CELL
BUTTON
H
H
T
BOLT
LOAD CELL
FLAT WASHER (NOT INCLUDED)
SPHERICAL WASHER SET
STRUCTURE
10 VDC REGULATED POWER SUPPLY
WASHER
LOAD CELL
METER
GREEN (+SIG)
BLACK (–EXC)
RED (+EXC)
WHITE (–SIG)
+
+
= output/sensitivity x excitation
(2.13 mV/V) (10.0 VDC)
BOLT
FLAT WASHER
SPHERICAL WASHER
LOAD CELL
STRUCTURE
Loading...