Omega Products LCMWD-200KN User Manual

LOAD WASHERS
FOR MEASURING BOLT COMPRESSIONAL FORCES
STANDARD AND METRIC MODELS
Compression 0-200 lb to 0-200,000 lb 0-1000 to 0-200 kN
1 Newton = 0.2248 lb 1 daNewton = 10 Newtons 1 lb = 454 g 1 t = 1000 kgf = 2204 lb
LCWD/LCMWD Series
Standard
U 200 kN/200,000 lb Capacity U Compact Design U Spherical Washers
Included
U Load Buttons Included U Spherical Washers
Recommended When Used with Bolts
Load Button Recommended
U
When Used as Compression Load Cell
SPECIFICATIONS
Excitation: 10 Vdc (15V max) Output: 2 mV/V Accuracy (Linearity, Hysteresis and
Repeatability Combined):
10K lb/50 kN: ±0.5% BFSL >10K lb/50 kN: ±0.75% BFSL
Zero Balance: ±4.0% FSO Operating Temp Range:
-40 to 127°C (-40 to 260°F)
Compensated Temp Range:
16 to 71°C (60 to 160°F)
Thermal Effects: Zero: ±0.018% FSO/°C Span: ±0.018% FSO/°C
Safe Overload: 120% of capacity Ultimate Overload: 200% of capacity Bridge Resistance:
<50K lb/200 kN: 350 Ω min ≥50K lb/200 kN: 700 Ω
Full Scale Deflection: 0.001" typical Construction: Stainless steel Electrical:
1.5 m (5') insulated shielded cable
STANDARD
LCWD-500, with spherical washers (included), shown actual size.
METRIC
with spherical washers
and load button (included),
WIRING CODE
RED +EXC BLACK -EXC GREEN +OUT WHITE -OUT
O.D.
LCMWD-2KN,
shown actual size.
I.D.
Dimensions: mm (inch)
CAPACITY ID OD H
≤10K lb (50 kN) 10.2 (0.40) 25 (1.0) 9.0 (0.35)
20K lb (100 kN) 12.7 (0.50) 30 (1.2) 10 (0.40)
50K lb (200 kN) 19.3 (0.76) 44 (1.75) 13 (0.50)
100K lb 25.7 (1.01) 57 (2.25) 18 (0.70)
200K lb 38.4 (1.51) 77 (3.00) 32 (1.25)
Caution
This unit is not field serviceable.
H
CABLE
STANDARD MODELS
To Order
lb N NO. METERS
200 890 LCWD-200 500 2224 LCWD-500
1000 4448 LCWD-1K 2000 8897 LCWD-2K 5000 22,242 LCWD-5K 10,000 44,484 LCWD-10K 20,000 88,968 LCWD-20K 50,000 222,420 LCWD-50K 100,000 444,840 LCWD-100K 200,000 889,680 LCWD-200K
Comes complete with 4-point NIST-traceable calibration and 59 kΩ shunt data.
4-digit meter.
*
One set of spherical washers and one set of load buttons supplied with each load cell.
Ordering Examples: LCWD-500, 500 lb capacity load washer supplied with 2 load buttons
and a set of spherical washers. LCWD-100K, 100,000 lb capacity load washer supplied with 2 load buttons and set of
spherical washers.
Visit omega.com/lcwd for Pricing and Details
CAPACITY MODEL COMPATIBLE
Modifying and/or tampering will forfeit
the warranty and may be dangerous.
Use appropriate protective equipment
and/or garments when testing or
installing, including safety glasses.
SPHERICAL WASHERS
MODEL ID
DP41-S, DP25B-S, DPiS DP41-S, DP25B-S, DPiS DP41-S, DP25B-S, DPiS DP41-S, DP25B-S, DPiS DP41-S, DP25B-S, DPiS DP41-S, DP25B-S*, DPiS* DP41-S, DP25B-S*, DPiS* DP41-S, DP25B-S*, DPiS* DP41-S, DP25B-S*, DPiS* DP41-S, DP25B-S*, DPiS*
SPW-2 8.7 (0.34) SPW-2 8.7 (0.34) SPW-2 8.7 (0.34) SPW-2 8.7 (0.34) SPW-2 8.7 (0.34) SPW-2 8.7 (0.34) SPW-3 10 (0.41) SPW-5 17 (0.66) SPW-7 24 (0.94) SPW-10 33 (1.31)
mm (inch)
F-83
F
I
R
LOAD WASHERS FOR MEASURING BOLT COMPRESSIONAL FORCES
STANDARD AND METRIC MODELS
METRIC MODELS
To Order Visit omega.com/lcwd for Pricing and Details
MODEL COMPATIBLE
LCMWD-1KN LCMWD-2KN LCMWD-5KN LCMWD-10KN LCMWD-20KN LCMWD-50KN LCMWD-100KN LCMWD-200KN
DPiS, DP41-S, DP25B-S DPiS, DP41-S, DP25B-S DPiS, DP41-S, DP25B-S DPiS*, DP41-S, DP25B-S* DPiS*, DP41-S, DP25B-S* DPiS*, DP41-S, DP25B-S* DPiS*, DP41-S, DP25B-S* DPiS*, DP41-S, DP25B-S*
METRIC
LCMWD-1KN, with spherical washers (included), shown actual size.
CAPACITY
N lb NO. METERS MODEL ID
1000 225
2000 450 5000 1124 10,000 2248 20,000 4496 50,000 11,240 100,000 22,481 200,000 44,962
Comes complete with 5-point NIST-traceable calibration and 59 kΩ shunt data.
4-digit meter.
*
One set of spherical washers and one set of load buttons supplied with each load cell.
Ordering Examples: LCMWD-10KN, 10 kN capacity load washer supplied with 2 load buttons
and a set of spherical washers. LCMWD-200KN, 200 kN capacity load washer supplied with 2 load buttons and a set of
spherical washers.
SPHERICAL WASHERS
SPW-2 8.7 (0.34) SPW-2 8.7 (0.34) SPW-2 8.7 (0.34)
SPW-2 8.7 (0.34) SPW-2 8.7 (0.34) SPW-2 8.7 (0.34) SPW-3 10 (0.41) SPW-5 17 (0.66)
STRAIN GAGE/BRIDGE TRANSDUCER-SIGNAL CONDITIONERS
iDRX-ST
U Unipolar/Bipolar
30 mV to 100 mV
U 13-Bit Resolution U 10 Vdc Excitation U 0.2% FS Accuracy U 1800 Vdc Isolation U 250 Vac/1 Min Input
Overvoltage Protection
U Free Setup and
Configuration Software
The iDRN-ST and iDRX-ST signal conditioners provide highly accurate, stable, isolated measurement for strain gage transducers such as load cells, torque transducers, non-amplified pressure transducers, and other bridge based transducers. Both models can accept signals from 30 to 100 mV full scale and provide 10 Vdc reference voltage which may be used for transducer excitation.
Shown smaller than actual size.
To Order Visit omega.com/drn-drx for Pricing and Details
MODEL NO. DESCRIPTION iDRX-ST Digital signal conditioner for strain gages and bridge transducers
with RS485 output iDRN-ST Signal conditioner for strain gages and bridge transducers with
analog output
-FS Factory setup and scaling
Comes complete with operator’s manual. Ordering Example: iDRX-ST, digital signal conditioner for strain gages and bridge
transducers with RS485 output, CAT-285, bi-directional RS232-RS485 converter for iDRX series.
For iDRN/iDRX accessories and power supplies, please visit omega.com/drn-drx
F-84
LOAD CELLS