CANISTER-STYLE COMPRESSION
LOAD CELLS
STANDARD AND METRIC MODELS
LC1001/LCM1001 Series
LC1011/LCM1011 Series
Compression
0-500 lb to 0-2 M lb
0-250 to 0-10,000 kgf
Starts at
LC1011-1K, connector style,
$895, shown actual size, see
next page for dimensions.
$
895
Standard
⻬ FM/CSA-Approved
Intrinsically Safe Models
Available
⻬ 0.25% Interchangeability
for Multiple Load Cell
Applications
⻬ 5-Point NIST-Traceable
Calibration (Standard)
⻬ Canister Design Ideal for
Axial Compression
Applications
⻬ Heavy-Duty,
Environmentally Sealed
Case for Harsh
Environments
⻬ Dual-Bridge
Models Available
SPECIFICATIONS
Excitation: 10 Vdc (15 Vdc max)
Output: 2 mV/V ±0.25%
Agency Approvals: CSA
Intrinsically Safe: IS/I.II.III/1/CDEFG
FM Hazardous Location: S/I/1/ABCD
(must be specified at time of order)
5-Point Calibration (in Compression):
0%, 50%, 100%, 50%, 0%
calibrated to full scale up to 300,000 lb;
load cells over 300,000 lb calibrated at
300,000 lb. For a full scale calibration
over 300,000 lb, specify option “-FS”
after model number (consult Sales for
price and delivery).
LC1011/LCM1011
models with
twist-lock connector.
Protection Class: IP67
Linearity: ±0.05% FSO
Hysteresis: ±0.03% FSO
Repeatability: ±0.02% FSO
Zero Balance: ±1% FS
Operating Temp Range:
-46 to 100°C (-50 to 212°F)
Compensated Temp Range:
16 to 71°C (60 to 160°F)
Thermal Effects:
Zero: ±0.0018% FS/°C
Span: ±0.0018% rdg/°C
Safe Overload: 150% of rated capacity
Ultimate Overload:
300% of rated capacity
Input Resistance: 350 ±10 Ω
F-94
LOAD CELLS
Output Resistance: 350 ±10 Ω
FS Deflection: 0.18 to 0.50 mm
(0.007 to 0.020") typical
Construction:
Metric and Standard Ranges
<500,000 lb: 17-4 PH stainless steel
Ranges ≥ 500,000 lb: High-alloy steel
Electrical:
LC1001/LCM1001: 4.8 m (15')
4-conductor shielded PVC cable
LC1011/LCM1011: PTIH-10-6P
(or equiv.)
Mating Connector: PT06F10-6S,
$26.50 (sold separately)
WIREPIN CONNECTION
GNA +OUTPUT
WTB -OUTPUT
BKC&E-INPUT
RED D&F +INPUT
YELLOW SHIELD
WIRING CODE
D
G
B
SPHERICAL RAD.
C
E
K THREADS, 4 HOLES EQ. SP.
ON "I" DIA.
PTIH-10-6P
OR EQUAL
1.13
(29)
BRIDGE NO.2 WHEN SPECIFIED
HEAVY-DUTY CANISTER STYLE COMPRESSION LOAD CELLS
Models
Available with
Built-In Amplifiers!
LC1011-10K,
connector
style, $895,
shown
smaller than
actual size.
POPULAR OPTIONS Price
0 to 5 Vdc Output “-5V” $175
Overload Stops: “-OL”
Dual Bridge:
≤2000 kgf (≤5000 lb) “-DUAL” 250
>2000 kgf (>5000 lb) “-DUAL” 350
Extended Temperature Range:
-45 to 93°C
(-50 to 200°F) “-TC1” 50
-45 to 177°C
(-50 to 350°F) “-TC2” 225
Watertight Cable Exit: “-WTC” 125
Additional Cable Length: 6.50/ft
Consult
Factory
Mating
Connector
PT06F10-6S
$26.50
Dimensions: mm (in)
CAPACITY
kgf (lb) BCDE G±.005 K (THREAD) kg (lb)
250 to 1K 116 32 89 6 32 60 M10 x 1.5 x 3⁄8 DP 2.7
(500 to 10K)
(4.6) (1.25) (3.50) (0.25) (1.25) (2.375)3⁄8-24 UNF-2B x 3⁄8 DP (6)
2K to 5K 151 32 89 19 46 60 M10 x 1.5 x 3⁄8 DP 4.5
(5K to 10K)
10K
(20K to 50K)
(100,000)
(200,000)
(300,000)
(400,000)
(500,000)
(1,000,000)
(2,000,000)
(5.9) (1.25) (3.50) (0.75) (1.81) (2.375)3⁄8-24 UNF-2B x 3⁄8 DP (10)
191 32 114 19 77 60 M10 x 1.5 x 3⁄8 DP 9
(7.5) (1.25) (4.50) (0.75) (3.44) (2.375)3⁄8-24 UNF-2B x 3⁄8 DP (20)
232 44 141 27 121 102
(9.1) (1.75) (5.56) (1.06) (4.75) (4.000) (40)
295 64 168 27 159 140
(11.6) (2.50) (6.63) (1.06) (6.25) (5.500) (95)
356 76 219 33 194 140
(14) (3.00) (8.63) (1.31) (7.63) (5.500) (105)
356 89 219 33 194 140
(14) (3.50) (8.63) (1.31) (7.63) (5.500) (140)
356 89 219 22 194 89
(14) (3.50) (8.63) (0.88) (7.63) (3.500) (170)
356 140 219 22 140 114
(14) (5.50) (8.63) (0.88) (5.50) (4.500) (250)
406 178 273 25 152 140
(16) (7.00) (10.75) (1.00) (6.00) (5.500) (400)
I
1
⁄2-20 UNF-2B x 1⁄2 DP
5
⁄8-18 UNF-2B x 1 DP
3
⁄4-16 UNF-2B x 11⁄4 DP
3
⁄4-16 UNF-2B x 11⁄4 DP
1
⁄2-20 UNF-2B x 3⁄4 DP
5
⁄8-18 UNF-2B x 1.0 DP
1-14 UNS-2B x 11⁄4 DP
WEIGHT
88
43
48
64
77
115
182
F-95