Temperature and Humidity  
Virtual Chart Recorder
iTHX Series
FCC-B
U Web Server 
U Alarms by Email or Text 
Message
U No Special Software Required 
U Records Years of Data on 
Popular SD Cards
U Dual Probe Option
®
™
View Temperature + Humidty with 
a Web Browser
The OMEGA® iTHX-SD transmitter 
let’s you monitor and record 
Temperature, Relative Humidity and 
Dew Point over an Ethernet network 
or the Internet with no special 
software except a Web Browser.
The iTHX-SD serves Active Web 
Pages to display real time readings, 
display charts of temperature, 
humidity, and dew point or log  
data in standard data formats 
for use in a spreadsheet or data 
acquisition program such as Excel 
or Visual Basic.
The virtual chart viewed on the web 
page is a JAVA™ Applet that records 
a chart over the LAN or Internet in 
real time. With the iTHX-SD, there 
is no need to invest time and money 
learning a proprietary software 
program to log or chart the data.
SD Flash Memory Card 
The iTHX-SD comes complete 
with a removable 2 GB SD Flash 
Memory card that can store up to 
seven years of readings taken at ten 
second intervals. 
Records on SD Flash Cards
The data is recorded on widely 
available SD (Secure Digital) flash 
cards. The format is a simple text 
file that is easily imported to spread 
sheets and other programs. It can 
be read on a PC or MAC with a USB 
card reader. You can also download 
the data remotely over an Ethernet 
network or the Internet. 
Alarm Relays
The iTHX-SD features 
two 1.5 Amp relays. 
With the easy 
Web-based setup page, 
the two relays can be 
programmed for an 
combination of temperature 
or humidity, and high or low 
set points. The relays can 
also be programmed to remain 
latched and require a manual 
reset if a limit is exceeded.
Battery Backup
The iTHX-SD comes with a 
universal 100 to 240 Vac power 
adapter. A standard 9 Volt Alkaline 
battery (also included) allows the 
device to log data for up to 2 days 
without external ac power. A failure 
on the Ethernet network will not 
interrupt data recording.
Adjustable Charts
Chart scales are fully adjustable on 
the fly. For example, the chart can 
display one minute, one hour, one 
day, one week, one month or one 
year. Temperature and humidity can 
be charted across the full span  
(-40 to 124°C, and 0 to 100% RH) or 
within any narrow range such as (20 
to 30°C). When a second sensor is 
added, users can select a chart that 
records channel 1, channel 2 or the 
difference of the two channels.
Award-Winning Technology
The iTHX-SD is simple to install and 
use, and features OMEGA’s awardwinning iServer technology that 
iTHX-SD-5D shown smaller 
than actual size with 
SD card and DB9-Y cable 
for dual probe (included).
requires no special software except 
a Web Browser.
The iTHX-SD connects to an 
Ethernet Network with a standard 
RJ45 connector and sends data in 
standard TCP/IP packets. It is easily 
configured with a simple menu 
using a Web Browser and can be 
password protected.
From within an Ethernet LAN 
or over the Internet, the user 
simply types its IP address or an 
easy to remember name such as 
“Cleanroom5” or “ServerRoom” in 
any Web Browser, and the iTHX-SD 
serves a Web Page with the current 
readings.
R-5

View temperature and humidity 
over Ethernet or the Internet.
Email Alarms
All OMEGA iTHX-SD models that 
are on a LAN that is connected to 
the Internet can trigger an alarm 
that can be sent by email to a user 
or a distribution list anywhere in the 
world, including text messages to 
cell phones and PDA’s.
Link to Web CAM or  
IP Camera
The Web page includes a link to 
a “Web Cam” or “IP camera” (not 
included). If you get a message 
about an alarm condition, you can 
quickly click on the link to view the 
actual scene over the Internet.
Display and Chart 
Two Channels
The iTHX-SD transmitters come 
complete with a temperature and 
humidity probe for measurement of 
a single location. With the addition 
of a second probe, the iTHX-SD 
transmitter can measure and display 
temperature, humidity and dew point 
in a second location up to ten feet 
away.
The transmitter can display and 
chart absolute measurements in 
both locations, or a differential 
measurement between the two 
locations. The second probe 
requires no change to the basic 
iTHX-SD transmitter hardware, 
it can be added at the time of 
purchase or in the future. OMEGA 
offers a choice of industrial 
probes in 2 and 5" lengths, and 
a wand style for ambient indoor 
applications. A simple DB-9 “Y” 
connector is available for adding a 
second probe.
Sensor and Calibration
It is not necessary to take 
the iTHX-SD out of service 
for routine calibration. The 
temperature/humidity sensors 
are interchangeable and can be 
replaced for about the same cost as 
a typical calibration. OMEGA offers 
replacement sensors with optional 
3-point NIST traceable calibration 
certificates.
Typical Applications
The iTHX-SD is great for 
monitoring temperature + humidity 
in applications such as: clean 
rooms, computer rooms, HVAC 
systems, pharmaceutical and food 
processing and storage, hospitals, 
laboratories, semiconductor fabs, 
electronic assembly, warehousing, 
museums, manufacturing, greenhouses, farm animal shelters,  
and many more.
Readings through embedded Web server
Sensor Specifications
RELATIVE HUMIDITY (RH)
Accuracy/Range: 
 10 to 90%: ±2% 
 5 to 10% and 90 to 95%: ±3%  
 0 to 5% and 95 to 100%: ±4%
Non-linearity: ±3% 
Hysteresis: ±1%RH 
Response Time: 8 seconds, tau 63% 
Repeatability: ±0.1% 
Resolution: 0.1%, 12 bit
TEMPERATURE (T)
Accuracy/Range* 
Wand Probe: ±0.5°C (±1°F) for 5 to 
45°C (41 to 113°F); up to ±1°C 
(up to ±2°F) for 0 to 5°C and 45 to 60°C 
(32 to 41°F and 113 to 140°F)
Industrial Probe: (see chart in manual) 
±0.5°C (±1°F) for 5 to 45°C (41 to 113°F); 
up to ±1.5°C (up to ±2.7°F) for -40 to 
5°C and 45 to 124°C  
(-40 to 41°F and 113 to 255°F)
*Note: extended temperature range is for 
Ind. probe only, the iServer’s operating 
temperature is 0 to 60°C
Response Time: 5 to 30 seconds,  
tau 63%
Repeatability: ±0.1°C 
Resolution: 0.1°C, 14-bit
Probe Specifications
Wand Probe: 
198 L x 19 mm Dia (7.8 L x 0.75" Dia) 
 Cable with DB9 Connector:  
 152 mm L (6" L) 
 Cable Operating Temperature: 
 0 to 80°C (32 to 176°F)
R-6
Industrial Probe 
iTHP-5, iTHP-2: 
137 L or 51 L x 16 mm Dia 
(5 L or  2 L x 0.63" Dia) 
 Housing Material: 316 SS 
 Cable with DB9 Connector: 
 3 or 0.9 m L (10 or 3')  
 Cable Operating Temperature: 
 -40 to 125°C (-40 to 257°F)
iServer Specifications
INTERFACES
Ethernet: (RJ45)  
 Fixed or auto-negotiating 
 10/100BASE-T, Auto MDI/MDIX
Supported Protocols:  
  TCP, UDP, SNMP, SMTP, 
NTP, ARP, ICMP, DHCP, DNS, 
HTTP and Telnet
Sensor: Digital 4-wire, DB9 
LCD Display: 16 digits, 6 mm (0.23") 
SD Flash Memory Card: 
2GB card: 8 months of data storage at 
1 second recording intervals or 7 years 
at 10 second intervals
Relay Outputs:  
Two relays 1.5 A @ 30 Vdc
Embedded Web Server:  
Serves Web pages containing real-time 
data and live updated charts within 
definable time intervals
Software: OPC Server; macro 
for datalogging in Excel program; 
compatible with Windows operating 
systems
Power
Input: 9 to 12 Vdc 
Safety qualified AC power adapter:  
 Nominal Output: 9 Vdc @ 0.5 A  
 Input: 100 to 240 Vac, 50/60Hz 
 (included)
Back-up Battery:  
 9 Vdc, alkaline (included)
ENVIRONMENTAL
Operating Temperature: 
 iServer unit: 0 to 60°C (32 to 140°F) 
 Battery: -18 to 55°C (0 to 131°F) 
 ac Adapter: 0 to 40°C (32 to 104°F)
Storage Temperature: -40 to 85°C  
(-40 to 185°F)
Packaging
Material: Steel metal case with wall 
mount bracket
R
NIST-Traceable Calibration
Certificate available. 
In compliance with ISO9001:2008, 
ISO10012-1.1992(E), 
ANSI/NCSL Z540-1.1994 
and MIL-STD-45662A.

270.4 [10.65]
61.6 [2.42]
36.6 [1.44]
90.3 [3.56]
88.9 [3.50]
54.1 [2.13] 
2.54 [0.10]
3.0 [0.12]
82.6 [3.25]
19.1 [0.75] 
12.7 [0.50 ] 
Weight: 389g 
(0.86 lbs)
Alarm relay configuration
through embedded Web server
Start Recording 
http://192.168.1.200Address
Overview 
Network 
Configuration 
Management 
Security
Recording
System 
Diagnostics 
Log Out
Readings
Web Link Setup
Chart
Current Date: 2099/01/01 Current Time: 00:00:00
Interval (1-3600)seconds
Type
Wrap
Set Date and Time
Start Date
Stop Date
Set Weekdays (only for scheduled recording)
Mon   Tue   Wed    Thur       Fri        Sat       Sun
yyyy/mm/dd
yyyy/mm/dd
Start Recording
Format SD CardStart Recording Status Data Retrieval
Category
Start Time
Stop Time
Title
Quick Start Recording
Continuous
hh:mm:ss(24 hours)
hh:mm:ss(24 hours)
Sensor configuration
Data logging spreadsheet
Dimensions: 
mm (inch) 
ø = diameter
Recording Setup
Replacement Probes with Calibration Certificate 
available, just add: “-CAL-3-HU”
Optional Probe Caps shown
iP-PCW
No need to take your unit out of 
iP-PCI
service for routine calibration. Order 
a calibrated probe instead. 
iP-SC
Standard
 To Order Visit omega.com/ithx-sd for Pricing and Details
 Model No.  Description
 iTHX-SD   iServer MicroServerTM for Temp, Humidity, and Dew Point. Includes standard 203 mm (8") wand 
 iTHX-SD-2  iServer MicroServerTM includes industrial 51 mm (2") probe, cable 0.9 m (3') with DB9 connector 
 iTHX-SD-5  iServer MicroServerTM includes industrial 137 mm (5") probe, cable 3 m (10') with DB9 connector 
 iTHX-SD-WD  iServer MicroServerTM includes two wand probes and “Y” cable  
 iTHX-SD-2D   iServer MicroServerTM includes two probes, wand and 51 mm (2") industrial probe with 0.9 m (3') 
 iTHX-SD-5D   iServer MicroServerTM includes two probes, wand and 137 mm (5”) industrial probe with 3 m (10') 
 Accessories 
 iTHP-W-6  Wand probe 203 mm (8"), cable 152 mm (6") 
 iTHP-2-DB9  Industrial probe 51 mm (2"), cable 0.9 m (3') 
 iTHP-5-DB9  Industrial probe 137 mm (5"), cable 3 m (10') 
 DB9-CA-3  Extension cable, 0.9 m (3') with DB9 connectors 
 DB9-Y  DB9 “Y” connector adaptor for 2 probes with DB9 connector 
 iP-PCI-10P  Porous polyethylene industrial probe cap, for wet environments, 10 caps per pack 
 iP-PCW-10P  Porous polyethylene wand probe cap, for wet environments, 10 caps per pack
iP-SC 
CAL-3-HU
 NIST traceable calibration certificate. 3 points of 25%, 50%, 75% RH, 
 CT485B-CAL-KIT  Calibration kit, 33% and 75% RH standards
* -CAL-3-HU 
† Other lengths of cable (up to 40') are available, please contact our Sales Department.  Note: Volume discounts are available. 
Ordering Examples: iTHX-SD with LCD display, SD card, 2 relay alarm, battery back-up and wand probe.  
iTHP-W-6-CAL-3-HU, calibrated replacement probe with certificate.
probe, cable 152 mm (6") with DB9 connector  
cable and “Y” cable
cable and “Y” cable 
†
†
 Porous stainless steel probe cap, 5 um porosity, for dusty,  
pressurized (<35 psi) environments
temperature 25°C (77°F), for new units
 Calibrated replacement probe and NIST traceable calibration certificate  
(for * insert probe type) 