Environmental Monitoring and Recording Over the Internet
Temperature + Humidity and Dew Point
U Virtual Chart Recorder
U Web Server
U Alarms by Email or Text Message
U No Special Software Required
U Record Years of Data on Popular
SD Cards
iSD Series
FCC-B
The OMEGA® iSD environmental monitor provides
Web-based remote surveillance of environmental
conditions in critical HVAC applications such as
computer server rooms, clean rooms, laboratories,
museums, warehouses, or any remote facility.
View and record Temperature, Relative Humidity and
Dew Point over an Ethernet network or the Internet
with no special software—just a Web browser.
Email Alarms
The device can trigger an alarm if temperature or
humidity goes above or below a set point that you
determine. Your alarm can be sent by email to a
single user or to a group distribution list, including text
messages to cell phones and PDA’s.
Physical Threats
The OMEGA iSD includes screw terminals for two
contact closures that work with common alarm
sensors. You can instruct the iSD monitor to send an
alarm if a door is opened, a window is broken, or a fire
sprinkler goes off.
iSD-TH, shown
smaller than
actual size.
Power Failure
The iSD monitor can trigger an alarm if the AC power
fails. The iSD monitor will continue to collect data for
two days powered by a standard 9 Volt alkaline battery
(included). A failure on the Ethernet network will not
interrupt data recording.
Local Alarms
The OMEGA iSD monitor includes two 1.5 Amp output
relays that are controlled by the alarm conditions you
select. The relays can trigger flashing lights and a siren
for example to alert personnel near the scene.
With the easy Web-based setup page, the two
relays can be programmed for any combination of
temperature or humidity, and high or low set points, as
well as alarm conditions triggered by contact closures.
The relays can also be programmed to turn off when
conditions return to normal, or programmed to remain
latched and require a manual reset.
To Order, Call or Shop Online at omega.com
SM
1

View Charts and Graphs
on the Web
The OMEGA iSD serves Active Web
Pages to display real time readings,
display charts of temperature and
humidity, or log data in standard data
formats for use in a spreadsheet or
data acquisition program such as
Excel or Visual Basic.
The virtual chart viewed on the web
page is a JAVA™ Applet that records
a chart over the LAN or Internet in
real time. With the OMEGA iSD,
there is no need to invest time
and money learning a proprietary
software program to log or chart the
data Chart scales are fully adjustable
on the fly. For example, the chart can
display one minute, one hour, one
day, one week, one month or
one year.
Temperature and humidity can be
charted across the full span
(-40 to 124°C, and 0 to 100% RH) or
within any narrow range such as
(20 to 30°C).
Recording Setup
IP Camera
The Web page includes a link to
a “Web Cam” or “IP camera” (not
included). If you get a message
about an alarm condition, you can
quickly click on the link to view the
actual scene over the Internet.
SD Flash Memory Card
The iSD comes complete with a
removable 2 GB SD Flash Memory
card that can store up to seven years
of readings taken at ten second
intervals.
Records on SD Flash Cards
The data is recorded on widely
available SD (Secure Digital) flash
cards. The format is a simple “.txt”
text file that is easily imported to
spread sheets and other programs.
It can be read directly on a PC or
MAC with a USB card reader. You
can also download the data remotely
over an Ethernet network or the
Internet.
Sensor and Calibration
The iSD monitors come complete
with a plug-in temperature and
humidity probe that mounts on the
instrument or separately with the six
foot extension cable (included).
It is not necessary to take the iSD
monitor out of service for routine
calibration. The temperature/
humidity sensors are interchangeable
and can be replaced for about the
same cost as a typical calibration.
OMEGA offers replacement sensors
with optional 3-point NIST traceable
calibration certificates.
iP-PCW, polyethylene
cap option, no charge.
iP-PCI, porous
polyethylene
cap option.
iP-SC, porous
stainless steel
cap option.
Installation and
operation of the
OMEGA iSD monitor
requires no special training, tools, or
software. The device connects to any
Ethernet network with standard cable
and plugs and is powered by any AC
outlet supplying 110 to 240 Vac.
Award-Winning Technology
The OMEGA iSD is simple to install
and use, and features OMEGA’s
award-winning iServer technology
that requires no special software
except a Web Browser.
View temperature and humidity
over Ethernet or the Internet.
The iSD connects to an Ethernet
Network with a standard RJ45
connector and sends data in
standard TCP/IP packets. It is easily
configured with a simple menu
using a Web Browser and can be
password protected. From within an
Ethernet LAN or over the Internet,
the user simply types its IP address
or an easy to remember name
such as “Cleanroom 5” or “Midwest
Server Room” in any Web Browser,
and the iSD serves a Web Page
with the current readings.
Typical Applications
The OMEGA iSD is great for
monitoring temperature + humidity
in applications such as: clean
rooms, computer rooms, HVAC
systems, pharmaceutical and food
processing and storage, hospitals,
laboratories, semiconductor fabs,
electronic assembly, warehousing,
museums, manufacturing,
greenhouses, farm animal shelters,
and many more.
Data logging spreadsheet
2
To Order, Call or Shop Online at omega.com
SM

Specifications
RELATIVE HUMIDITY SENSOR
Accuracy/Range: ±2% for 10 to
90%; ±3% for 5 to 10% and 90 to
95%; ±4% for 0 to 5% and
95 to 100%
Non-linearity: ±3%
Hysteresis: ±1% RH
Response Time: 8 seconds,
tau 63%
Repeatability: ±0.1%
Resolution: 0.1%, 12 bit
TEMPERATURE SENSOR
Accuracy/Range*
Wand Probe: ±0.5°C (±1°F) for
5 to 45°C (41 to 113°F); up to
±1°C (up to ±2°F) for 0 to 5°C and
45 to 60°C (32 to 41°F and
113 to 140°F)
Industrial Probe: (see chart in
manual) ±0.5°C (±1°F) for 5 to 45°C
(41 to 113°F); up to ±1.5°C (up to
±2.7°F) for -40 to 5°C and 45 to
124°C (-40 to 41°F and 113 to 255°F)
*Note: extended temperature range is for Ind.
probe only, the iServer’s operating temperature
is 0 to 60°C
Response Time: 5 to 30 secs,
tau 63%
Repeatability: ±0.1°C
Resolution: 0.1°C, 14 bit
Standard Probe Dimensions:
Ø13 x 83.8 mm L (Ø 0.5 x 3.3" L)
INDUSTRIAL PROBE ISD-THP-5
Probe: Ø16 x 137 mm L (0.63 x 5")
Housing Material: SS 316
Cable Length: 3 m (10')
Dimensions: mm (inch)
Cable Operating Temperature:
-40 to 125°C (-40 to 257°F)
INTERFACES
Ethernet (RJ45): Fixed or auto-
negotiating 10/100BASE-T,
Auto MDI/MDIX
Protocols: TCP, UDP, SNMP, SMTP,
NTP, ARP, ICMP, DHCP, DNS, HTTP,
and Telnet
LCD Display: 32 digits 4.8 x 9.7 mm
(0.19 x 0.38")
SD FLASH MEMORY CARD
2 GB Card: 8 months of data
storage at 1 second recording
intervals or 7 years at 10 secintervals
Relay Outputs: Two relays 1.5A @
30 Vdc
Alarm I/Os: Two contact inputs, TTL
0.5 mA with 10K pull-up; one open
collector output 150 mA @ 30 Vdc
Embedded WEB Server:
Serves WEB pages containing realtime data and live updated charts
within definable time intervals
25.4 (1.00) 130.2 (5.13)
82.6 (3.25)
64.8 (2.55)
C/ F TIME/IPBKLT
TEMPERATURE/HUMIDITY
ø = diameter
POWER
Input: 9 to 12 Vdc
AC Power Adaptor (Included):
Input: 100 to 240 Vac, 50/60Hz
Nominal Output: 9 Vdc @ 0.5 A
Back-Up Battery: 9 Vdc, Alkaline
(included)
Operating Temperature:
iServer Unit: 0 to 60°C
(32 to 140°F)
Battery: -18 to 55°C (0 to 131°F)
AC Adaptor: 0 to 40°C
(32 to 104°F)
PACKAGING
Weight: 490 g (1.08 lb)
Material: SS 304 case with wall
mount bracket
Replacement probes with calibration
certificate available, just add:
“-CAL-3-HU”
No need to take your unit out of
service to get re-calibrated, order a
calibrated probe instead.
RECORDING
DHCP
LINK/ACT
100 BASE-T
88.1 (3.47)
33.3
(1.31)
2.54
(0.10)
To Order
Visit omega.com/isd-th for Pricing and Details
Model No. Description
iSD-TH iSD monitor for temperature + humidity, standard probe, 1.8 m (6') extension cable
iSD-TH-5 iSD monitor for temperature + humidity, 137 mm (5") industrial probe with 3 m (10') cable
Accessories
iSDTHP Replacement standard right angle probe
iSDTHP-5 Replacement industrial 137 mm (5") probe, cable 3 m (10')
iP-PCW-10P Porous polyethylene right angle probe cap, for wet environments, 10 pack
IP-PCI-10P Porous polyethylene industrial probe cap, for wet environments, 10 pack
iP-SC Porous stainless steel probe cap, 5 µm porosity, for dusty and pressurized (<35 psi) environments
Calibration for New Units
CAL-3-HU NIST traceable calibration certificate. Three humidity points: 25%, 50%, 75%, one temperature 25°C,
CT485B-CAL-KIT Calibration kit, 33% and 75% RH standards
for new units.
For Calibrated Replacement Probes, Including Calibration Certificate
iSDTHP-CAL-3-HU Standard right angle probe and NIST traceable calibration certificate
iSDTHP-5-CAL-3-HU Industrial probe and NIST traceable calibration certificate
Comes complete with LCD display, 2 GB SD flash memory card, 2 relay alarms, battery back-up, universal 100 to 240 Vac power adaptor and
operator’s manual.
Ordering Examples: iSD-TH, monitor for temperature plus humidity with a right angle probe and 1.8 m (6') extension cable.
iSD-TH-5, monitor for temperature plus humidity with industrial 137 mm (5") probe and 3 m (10') cable.
To Order, Call or Shop Online at omega.com
SM
3