Omega Products iDRN-PR User Manual

Analog & Digital Output Signal Conditioners/Transmitters
iDRN/iDRX Series
U Analog or Digital Output U Models Available for:
Thermocouple, RTD, Process Voltage & Current, Strain, Frequency/Pulse, AC Voltage and Current
U Up to 1800 Vdc Isolation U iDRN Series Provide
0 to 10 Vdc, 4 to 20 mA or 0 to 20 mA Output
U iDRX Series Provide RS‑485
Output (ASCII Serial Protocol and MODBUS Serial Protocol)
U Free Setup and Configuration
Software
U Factory Setup and
Configuration Available at No Charge (for iDRN Analog Output Models)
The new iD Series signal conditioners combine the accuracy of laboratory instrumentation with the performance required by demanding industrial applications. The iD Series signal conditioners are ideal for those applications in Data Acquisition, Test & Measurement, Process Control, and Industrial Automation where accuracy, performance, and reliability are critically important.
The iD Series signal conditioners mount on a 35mm DIN rail, and operate on any voltage between 10 to 32 DC power. (A matching 24 Vdc 850 mA switching power supply is also available.) The devices feature three-way isolation of up to 1800 Vdc between the signal inputs, outputs, and power supply.
The iD series feature seven (7) models designed for each of the most widely measured signal inputs: Process (DC) Voltage and Current; Strain Gage; Thermocouples; RTD’s; AC Voltage; AC Current; Frequency/Pulse.
The iD series devices are designed to work directly with a variety of sensors and transducers; no other components are necessary. For sensors such as RTD’s, strain gages, and some process transducers, precise stable excitation is provided directly from the iD module.
The iD series are available with two different types of signal outputs: Analog or Digital. The iDRN series provides a totally scalable analog output in DC voltage or current. The iDRX series provide a digital RS-485 output. Both iD Series signal conditioners are intelligent microprocessor based instruments that can be scaled and programmed by computer via serial communications, or over an Ethernet network.
iDRN Series Analog Output
The iDRN series feature a 0 to 10 Vdc, or 0 to 20 mA (including 4 to 20 mA) analog output signal that is typically scaled to be directly proportional to the input signal. It is an ideal component in a system with PLC’s or PC’s with analog data acquisition boards.
The iDRN series are an excellent choice for applications that demand an extra measure of accuracy and performance that is not possible with conventional “analog” signal conditioners or transmitters. Unlike conventional analog devices that are scaled by adjusting zero and span “pots”, the programmable, micro-processor based iDRN instruments are scaled precisely on a PC with free and simple Windows software. The iDRN modules connect directly to a PC’s RS-232 Serial Communications port for programming and scaling.
Once the module is configured, the parameters are saved in non­volatile memory. The device can be disconnected from the PC, or the RS-232 output from the module can be used for continuous data acquisition in addition to the analog output.
Alternatively, the iDRN signal conditioner can be connected to a PC’s Ethernet port or an Ethernet network using the EIT module as a Serial/Ethernet bridge.
To Order, Call or Shop Online at omega.com
SM
1
Free Setup and Configuration
If an iDRN signal conditioner is not going to be connected to a computer, it can be ordered preconfigured by the factory at no extra charge. The user can select the input types, ranges and output scale, and OMEGA will program the instruments to those specific requirements in our calibration lab prior to shipment. For custom factory setup and scaling of the iDRN model, please specify the “-FS” option.
iDRX Series Digital Output
The iDRX Series Signal Conditioners provide highly accurate digital outputs. Each module provides an RS-485 Serial output that can be transmitted directly to computers and other devices with serial communications capability, or converted to Ethernet.
On an RS-485 bus, up to 32 modules can be connected over a distance of 1200 m (4000') on a single pair of wires. With optional RS-485 repeaters, up to 254 modules may be connected to a single RS-485 port. The iDRX Series digital conditioners may be connected to an RS-485 bus using either screw terminator or RJ-12 connector.
ASCII and MODBUS
The user can select between an easy-to-use, straightforward ASCII protocol, or the popular MODBUS protocol found in many existing industrial installations. With the simple ASCII commands, writing programs using the iDRX does not require special drivers or libraries. In addition, many off-the-shelf software packages can be used with the iDRX devices without any programming. OMEGA also provides a number of useful programs and demos for the iDRX at no charge.
OPC Server And Active X Controls
OMEGA offers an optional OPC Server (OLE for Process Control) and ActiveX Controls for the iDRX Series. These programs make it easy to integrate the iDRX devices with information systems using “ActiveX Containers” such as Microsoft Visual Basic and Microsoft Excel as well as with popular OLE and OPC compliant data acquisition, process control, and industrial automation software from OMEGA®, Iconics, Wonderware, Intellution, Rockwell Automation, and GE Fanuc Cimplicity among others.
iDRX and iDRN Series Common Specifications
Input Power Supply: 10 to 32 Vdc iDRX Output: 2-wire (half duplex)
RS-485 (OMEGA® Serial Protocol and Modbus Serial Protocol)
iDRN Output: 0 to 10V @ 10 mA max; 0 to 20 mA or 4 to 20 mA, 10V compliance
Isolation: 1800 Vdc peak Typical Step Response to 99%:
1 second
Operating Ambient:
-5 to 55°C (23 to 131°F)
Storage Temperature Range:
-40 to 85°C (-40 to 185°F)
Mounting: 35 mm DIN rail Dimensions: 90 H x 25 W x 107 mm D
(3.54 x 0.99 x 4.21")
Mounts to
35 mm
DIN rails.
RAIL‑35‑2, 2 m (6') long.
Input Thermocouple RTD ac Voltage ac Current Process Strain/Bridge Frequency Pulse Model No. iDRN/iDRX-TC iDRN/iDRX-RTD iDRN/iDRX-ACV iDRN/iDRX-ACC iDRN/iDRX-PR iDRN/iDRX-ST iDRN/iDRX-FP
Input Type Thermocouple RTD Temperature ac Voltage ac Current dc Millivolt, Millivolt NAMUR
temperature sensor Volt Contact closure sensor Pt100, 500, 1000Ω and Current low level open collector
Input Range J, K, T, E, α = 385, 392 Full Scale Range: Full Scale Range: Full Scale Range: 0 to 30 mV Full Scale Range R, S, B, N, J DIN Full range of RTD 400 mV to 400V 10 mA to 5 A ±400 mV to ±10V 0 to 100 mV 20k to 0 to thermocouple full range 2, 3 or 4-wire 0 to 20 mA ±100 mV 200 M pulses 50 kHz
Accuracy ±1°C ±0.5°C 0.2% 0.2% 0.1% FS 0.2% FS 0.1% FS Resolution 0.1°C 0.1°C 10 to 14 Bit 10 to 14 Bit 12 to 15 Bit 13 to 15 Bit 15 to 19 Bit Output iDRX Series: 2-wire (half duplex) RS-485/iDRN Series: 0 to 10V @ 10 mA max; 0 to 20 mA or 4 to 20 mA Excitation N/A N/A N/A N/A 14 Vdc @ 10V @ 5, 8.2 and 12.5 Vdc
25 mA 30 mA @ 25 mA
2
To Order, Call or Shop Online at omega.com
SM
A/IN
SERIAL I/O
DI/O
Access Vital information Anytime, Anywhere, on the World Wide Web.
Ethernet and Internet
The iDRX signal conditioner can also be connected to an Ethernet network using the EIT module as a Serial/Ethernet bridge. One EIT module can be a hub for up to 32 iDRX modules. The EIT module packages the ASCII serial communications in standard TCP/IP Protocol for transmission over standard Ethernet networks and the Internet. Unlike some manufacturer’s products this system uses totally open, non­proprietary standards and protocols for Ethernet and Internet. The user can integrate these devices with any commercial or industrial grade networking components that also comply with the popular international standards.
Get Internet E‑mail Notification of Alarm Status on your web enabled smartphone or blackberry.
Digital Output iDRX modules connected to Ethernet
iDRX modules on RS485 Serial Bus
To Order, Call or Shop Online at omega.com
SM
3
Loading...