Omega Products iBTHX-D User Manual

Barometric Pressure, Temperature, Humidity Virtual Recorder
iBTX Series
FCC-B
U Virtual Chart Recorder U Web Server U Alarms by Email or
Text Message
U No Special Software
Required
U iBTX-SD: Records
Years of Data on Popular SD Cards
Chart
http://192.168.1.200Address
Readings Chart Web Link Setup
High 150.0 / Low 78.0 High 1110.0 / Low 1020.0 Max. 130.1 / Min. 95.9 Max. 1090.8 / Min. 1034.1
Temperature Barometric Pressure
200
20.0 C/Div
0
Data Source:
Alarm Relay Set Points:
Help[?]
iBTX-D iServer MicroServer™ with industrial barometric pressure/ temperature probe (included), shown smaller than actual size.
108.2 F 1020.8 hPa
Live
Bold
Recording: ON
1 Hour/Div
X-axis: 1 Day
Y-axis (left): TemperatureStyle: Bold
Y-axis (right):
Bar. PresStyle: Bold
RAIL-35-2, DIN rail, sold separately.
PROBE INCLUDED!
Thu Sep 17 12:05:07 PDT 2009Thu Sep 16 08:00:00 PDT 2009
Save Chart
Print Chart
1200
90 hPa/Div
300
iBTX-SD shown smaller than actual size.
iBTHX-W shown smaller than actual size.
See Page
Hu-12
to Order!
View Barometric Pressure, Temperature, and Humidity with a Web Browser
The OMEGA® iBTHX transmitter let’s you monitor and record Barometric Pressure, Temperature, Relative Humidity and Dew Point over an Ethernet network or the Internet with no special software except a Web Browser.
The iBTHX serves Active Web Pages to display real time readings, display charts of Barometric Pressure, temperature, humidity, and dew point or log data in standard data formats for use in a spreadsheet or data acquisition program such as Excel or Visual Basic.
The virtual chart viewed on the web page is a JAVA™ Applet that records a chart over the LAN or Internet in real time. With the iBTHX, there is no need to invest time and money learning a proprietary software program to log or chart the data.
Hu-9
Adjustable Charts
Chart scales are fully adjustable on the fly. For example, the chart can display one minute, one hour, one day, one week, one month or one year.
Temperature and humidity can be charted across the full span (-40 to 85°C, and 0 to 100% RH) or within any narrow range such as (20 to 30°C).
Barometric Pressure can be displayed in hectopascals (hPa), millimeters of Mercury (mmHg), or inches of Mercury (inHg).
Chart
http://192.168.1.200Address
Readings Chart Web Link Setup
High 150.0 / Low 78.0 High 1110.0 / Low 1020.0 Max. 130.1 / Min. 95.9 Max. 1090.8 / Min. 1034.1
Temperature Barometric Pressure
200
Recording: ON
108.2 F 1020.8 hPa
1200
Typical Applications
The iBTHX is great for monitoring barometric pressure, temperature + humidity in applications such as: clean rooms, computer rooms, HVAC systems, pharmaceutical and food processing and storage, hospitals, laboratories, semiconductor fabs, electronic assembly, warehousing, museums, manufacturing, green-houses, farm animal shelters, and many more.
20.0 C/Div
0
Data Source:
Alarm Relay Set Points:
Help[?]
Live
Bold
1 Hour/Div
X-axis: 1 Day
Y-axis (left): TemperatureStyle: Bold
Y-axis (right):
Bar. PresStyle: Bold
90 hPa/Div
Save Chart
Print Chart
300
Thu Sep 17 12:05:07 PDT 2009Thu Sep 16 08:00:00 PDT 2009
Adjustable-chart Web page.
Display and Chart Measurements
The iBTHX transmitters come complete with a barometric pressure, temperature and humidity probe for measurement of a single location. OMEGA offers a choice of industrial probes in 5” lengths and a wand style for ambient indoor applications.
Award-winning Technology
The iBTHX is simple to install and use, and features OMEGA’s award-winning iServer technology that requires no special software except a Web Browser.
The iBHTX connects to an Ethernet Network with a standard RJ45 connector and sends data in standard TCP/IP packets.
It is easily configured with a simple menu using a Web Browser and can be password protected.
From within an Ethernet LAN or over the Internet, the user simply types its IP address or an easy to remember name such as “Cleanroom5” or “ServerRoom” in any Web Browser, and the iBTHX serves a Web Page with the current readings.
Email Alarms
All OMEGA iBTX models that are on a LAN that is connected to the Internet can trigger an alarm that can be sent by email to a user or a distribution list anywhere in the world, including text messages to cell phones and PDA’s.
NIST-traceable calibration certificate available.
In compliance with ISO9001:2008, ISO10012-1.1992(E),
ANSI/NCSL Z540-1.1994 and MIL-STD-45662A.
H
u
View barometric pressure and temperature via Ethernet or Internet.
NEW iBTX-SD with SD Flash Memory Card and LCD Display
The OMEGA model iBTX-SD with LCD display, adds several valuable features in addition to the backlit local display of barometric pressure and temperature.
SD Flash Memory Card
The iBTX-SD comes complete with a removable 2 GB SD Flash Memory card that can store up to seven years of readings taken at ten second intervals.
Records on SD Flash Cards
The data is recorded on widely available SD (Secure Digital) flash cards. The format is a simple “.txt” text file that is easily imported to spread sheets and other programs. It can be read on a PC or MAC with a USB card reader. You can also download the data remotely over an Ethernet network or the Internet.
Alarm Relays
The iBTX-SD features two 1.5 Amp relays. With the easy Web-based setup page, the two relays can be programmed for any combination of temperature or pressure, and high or low set points. The relays can also be programmed to remain latched and require a manual reset if a limit is exceeded.
Battery Backup
The iBTX-SD comes with a universal 100 to 240 Vac power adapter.
A standard 9 Volt Alkaline battery (also included) allows the device to log data for up to 2 days without external ac power. A failure on the Ethernet network will not interrupt data recording.
Hu-10
Sensor Specifications
Barometric Pressure (iBTX, iBTHX)
Accuracy/Range: ±2.0 mbar/
10 to 1100 mbar (1 to 110 kPa)
Resolution: 0.1 mbar
Relative Humidity (iBTHX)
Accuracy/Range: 10 to 90%: ±2% 5 to 10% and 90 to 95%: ±3% 0 to 5% and 95 to 100%: ±4%
Non-linearity: ±3% Hysteresis: ±1%RH Response Time: 8 seconds, tau 63% Repeatability: ±0.1% Resolution: 0.1%, 12 bit
Temperature (iBTHX)
Accuracy/Range*: Wand Probe: ±0.5°C for 5 to 45°C
(±1°F for 41 to 113°F); up to ±1°C for 0 to 5°C and 45 to 70°C (up to 2°F for 32 to 41°F and
113 to 158°F) Industrial Probe: (see chart in manual) ±0.5°C for 5 to 45°C (±1°F for 41 to 113°F); up to ±1.5°C for -40 to 5°C and 45 to 85°C (up ±2.7°F for
-40 to 41°F and 113 to 185°F)
Note: Extended temperature range is
*
for industrial probe only; the iServer’s operating temperature is 0 to 70°C.
Response Time: 5 to 30 seconds, tau 63%
Repeatability: ±0.1°C Resolution: 0.1°C, 14-bit
Temperature (iBTX)
Accuracy/Range*:
Wand Probe: ±0.8°C @ 20°C (±1.5°F @ 68°F); ±2°C for 0 to 70°C (±3.6°F for 32 to 158°F)
Industrial Probe: ±0.8°C @ 20°C (±1.5°F @ 68°F); ±2°C for -40 to 85°C (±3.6°F for -4 to 185°F)
Note: Extended temperature range is for
*
industrial probe only; the iServer’s operating temperature is 0 to 70°C.
Replacement probes with calibration certificate available, just add: “-CAL-3-HU” or “-CAL-3-P” or “-CAL-3-HU-P-T”
iP-PCI
Optional probe caps
shown, fits industrial
wand probe.
No need to take your unit out of service for routine calibration. Order a calibrated probe instead.
iP-SC
Data logging spreadsheet.
Probe Physical Dimensions
Wand Probe: 19 Dia x 159 mm L
(0.75 Dia x 6.25" L)
Cable with DB9 Connector:
Length: 152 mm (6") Operating Temp: 0 to 80°C (32 to 176°F)
Industrial Probe: 16 Dia x 137 mm L (0.63 Dia x 5" L)
Cable with DB9 or Stripped Leads: Length: 3 m (10') Operating Temp: -55 to 105°C (-67 to 221°F)
iServer Specifications
Interfaces
Ethernet (RJ45):
Fixed or auto-negotiating 10/100BASE-T, Auto MDI/MDIX: iBTX-SD; 10BASE-T: iBT(H)X-W, -D
Protocols
TCP, UDP, SNMP, SMTP, NTP, ARP, ICMP, DHCP, DNS, HTTP, and Telnet: iBTX-SD;
TCP, UDP, ARP, ICMP, DHCP, DNS, HTTP, and Telnet: iBT(H)X-W, -D
Sensor reading Web page.
Standard
iBTHX-W and iBTHX-D device
configuration Web page.
Sensor:
Digital 4-wire (DB9): iBT(H)X-W, iBTX-SD; removable 8 position screw terminals: iBT(H)X-D
LCD Display (iBTX-SD)
16 Digits, 6 mm (0.23")
SD Flash Memory Card (iBTX-SD)
2GB card: 8 months of data storage at 1 second recording intervals or 7 years at 10 second intervals
Relay Outputs (iBTX-SD)
Two Relays 1.5A @ 30 Vdc
Embedded WEB Server
Serves WEB pages containing real­time data and live updated charts within definable time intervals
Software
OPC Server; macro for datalogging in Excel program; compatible with Windows operating systems
Power
Input: iBT(H)X-W, iBTX-SD: 9 to 12 Vdc iBT(H)X-D: 10 to 32 Vdc
Safety-Qualified AC Power Adaptor Nominal Output: 9 Vdc @ 0.5 A Input (iBT(H)X-W, iBTX-SD):
100 to 240 Vac, 50/60 Hz (included) Switching Power Supply (iBT(H)X-D):
Sold separately (iDRN-PS-1000) Back-up Battery (iBTX-SD): 9V
alkaline (included)
Environmental Operating Temperature:
0 to 70°C (32 to 158°F) iBTX-W, -2 0 to 60°C (32 to 140°F) iBTX-SD
Battery: -18 to 55°C (0 to 131°F) ac Adaptor: 0 to 40°C (32 to 104°F) Storage Temperature:
-40 to 85°C (-40 to 185°F)
Packaging Material:
iBTX/iBTHX-W: Valox
case with wall mount bracket iBTX-SD: Steel metal case with wall bracket mount iBTX/iBTHX-D: Polycarbonate case with DIN rail mount
Dimensions: See next page
®
364 PBT
Hu-11
232.3 [9.15]
232.3 [9.15]
61.6 [2.42]
36.6 [1.44]
90.3 [3.56]
2.54 [0.10]
3.0 [0.12]
82.6 [3.25]
19.1 [0.75]
19.1 [0.75]
66.0 [2.60]
85.9 [3.38]
27.4 [1.08]
93.1 [3.67]
3.0 [0.12]
iBTX-SD
Dimensions:
mm (in)
iBTX-W, iBTHX-W
iBTX-D, iBTHX-D
Replacement Probes with Calibration Certificate available, just add: “- CAL-3-HU” or “- CAL-3-P” or “- CAL-3-HU-P-T”
No need to take your unit out of service for routine calibration. Order a calibrated probe instead.
iDRN-PS-1000
U 24 Vdc supply U Switching power supply powers
up to 7 units
To Order Visit omega.com/ibtx_ibthx for Pricing and Details
Model No. Description
iBTX-SD
iServer MicroServer
alarm and battery backup, with universal AC power adaptor
iBTX-W iServer MicroServer iBTHX-W
iServer MicroServer™ for barometric pressure, temperature, humidity and dew point, with AC power adaptor
* Standard wand probe, cable 152 mm (6") with DB9 connector (no entry required)
-5 Industrial 5" probe, cable 3 m (10') with DB9 connector (substitution for wand probe) Accessories iBTP-W-6 Wand probe, cable 152 mm (6") with DB9 connector (barometric pressure/temperature) iBTHP-W-6 Wand probe, cable 152 mm (6") with DB9 connector (barometric pressure/temperature/humidity) iBTP-5-DB9 Industrial 137 mm (5") probe, cable 3 m (10') with DB9 connector (barometric pressure/temperature) iBTHP-5-DB9
Industrial 137 mm (5") probe, cable 3 m (10') with DB9 connector (barometric pressure/temp/humidity)
DB9-CA-3-2 Extension cable, 0.9 m (3') with DB9 connector
Model No. Description
iBTX-D
cable 3 m (10'), stripped wire leads; DIN rail mount
iBTHX-D
industrial probe 137 mm (5"), cable 3 m (10'), stripped wire leads; DIN rail mount
Accessories
iServer industrial MicroServer
iServer industrial MicroServer
iBTP-5 Industrial probe 137 mm (5"), cable 3 m (10') with stripped wire leads; barometric pressure/temp iBTHP-5 Industrial probe 137 mm (5"), cable 3 m (10') with stripped wire leads; bar, pressure/temp/humidity iDRN-PS-1000 Power supply (switching), 95 to 240 Vac input, 24 Vdc output @ 850 mA (powers up to 7 units)
Common Accessories CAL-3-HU NIST-traceable calibration certificate, 3 humidity points: 25%, 50%, 75%, temp 25°C (for new units) CAL-3-HU-P-T
NIST-traceable calibration certificate, 3 humidity, barometric pressure and temp points (for new units)
CAL-3-P NIST-traceable calibration certificate, 3 barometric pressure points, temp 25°C (for new units) * -CAL-3-HU Calibrated replacement probe, and NIST traceable calibration certificate (for * insert probe type) * -CAL-3-HU-P-T Calibrated replacement probe, and NIST traceable calibration certificate (for * insert probe type) * -CAL-3-P Calibrated replacement probe, and NIST traceable calibration certificate (for * insert probe type)
CT485B-CAL-KIT
Calibration kit, 33% and 75% RH standards iP-PCI-10P Porous polyethylene industrial probe cap for wet environments, 10 caps per pack iP-SC Porous stainless steel probe cap, 5 µm porosity, for dusty and pressurized (<35 psi) environments
Ordering Examples: iBTHX-D, DIN rail mount industrial MicroServerTM for barometric pressure, temperature, humidity and dew point, with iDRN-PS-1000, power supply.
iBTX-W, bracket mounted iServer MicroserverTM for barometric pressure and temperature, with DB9-CA-3-2, extension cable. For calibrated replacement probe, with certificate: iBTHP-W-6-CAL-3-HU.
for barometric pressure and temperature, LCD, 2 GB SD flash memory card, 2-relay
for barometric pressure and temperature, with AC power adaptor
for barometric pressure and temp; industrial probe 137 mm (5"),
for barometric pressure, temp, humidity and dew point;
Hu-12
H
u
Loading...