1500A True RMS AC/DC Clamp 
Meter and Non-Contact Voltage
HHM-MA1500
U True RMS for Accurate Readings of 
Non-Sinusoidal Waveforms
U Built-In Non-Contact Voltage Detector 
with Led Alert
U 52 mm (2.0") Jaw Size for Conductors 
up to 500MCM
U Dual 40,000/4000 Count, Backlit LCD 
Display
U Includes Multimeter Functions 
U Inrush Function Captures Transients 
During Motor Startups
U Relative Mode for Capacitance Zero 
and Offset Adjustment
U Data Hold, Peak Hold, Min/Max, and 
Auto Power Off
The HHM-MA1500 is a true RMS clamp meter. This 
meter measures AC current, DC current, AC/DC 
voltage, resistance, capacitance, frequency, diode test, 
duty cycle and continuity. The molded case is designed 
for heavy-duty use. The integrated non-contact voltage 
detector quickly checks for the presence of live wires 
before testing needs to be started.
52 mm (2.0") jaw size for conductors up to 500MCM.
Test leads included for multimeter functions.
Q
HHM-MA1500 
shown smaller 
than actual size.
Q-1

       Max. Resolution 
 Specifications  Range  (%readings+digits)  Basic Accuracy
 Clamp Jaw Opening   52 mm (2.0") approx.  —  — 
 Display Counts   Dual 40,000/4000 count backlit LCD  —  — 
 Measurement Rate   2 readings per second, nominal  —  — 
 Peak Detector  >1ms  — — 
 Input Impedance   10MΩ (Vdc and Vac)  —  — 
 AC Bandwidth   50 to 400 Hz (AAC and Vac)  —  — 
 AC Response   True RMS (AAC and Vac)  —  — 
 Crest Factor   3.0 in 400A range, 1.4 in 1000A range 
   (50/60 Hz and 5% to 100% of Range 
 AC Current (True RMS)  400.00A,1500.0A  0.01A  ±(2.8%+30d) 
 DC Current  400.00A,1500.0A  0.01A  ±(2.5%+30d) 
 AC Voltage (True RMS)  400.00 mV, 4.000V, 40.00V, 750.0V  0.01mV  ±(1.0%+30d) 
 DC Voltage  400.00 mV, 4.0000V, 40.000V, 1000.0V  0.01mV  ±(0.1%+4d) 
 Resistance  400.00 Ω, 4.0000 kΩ, 40.000 kΩ, 
   400.00 kΩ, 4.0000 kΩ, 40.000M Ω  0.01Ω  ±(0.5%+9d) 
 Frequency  40 Hz to 40 MHz  0.001Hz  ±(0.3%+2d) 
 Capacitance  400.00nF, 4000nF, 40.00μF, 400.0μF, 
   4.000mF, 20.00mF, 40.00mF  0.01nF  ±(3.5%+10d) 
 Temperature  -100 to 1000°C (-148 to 1832°F)   0.1°  ±(1%+4.5°F/2.5°C) 
 Thermocouple Sensor  Type K thermocouple required  —  — 
 Duty Cycle  10.0 to 95.0%   0.1%  ±(1.0%+2d) 
 Diode  Test current of 0.3mA typical; 
   Open circuit voltage 2.8 Vdc typical 
 Continuity  Threshold 25 to 60Ω; 
   Test current < 0.5mA 
 Power  9V battery (included)  —  — 
 Low Battery Indication  Battery symbol is displayed  —  — 
 Over-Range Indication  ‘OL’ display  —  — 
 Auto Power Off  After approx. 30 minutes  —  — 
 Operating Temperature  5 to 40°C (41 to 104°F)  —  — 
 Storage Temperature  -20 to 60°C (-4 to 140°F)  —  — 
 Operating Humidity  Max 80% up to 31°C (87°F) 
   decreasing linearly  —  — 
   to 50% at 40°C (104°F) 
 Storage Humidity  <80%  — — 
 Operating Altitude  2000 m (7000') max  —  — 
 Dimensions  294 x 105 x 47 mm (11.57 x 4.13 x 1.85")  —  — 
 Weight  536 g (18.9 oz)  —  — 
 Safety  For indoor use and in accordance with 
   the requirements for double insulation to 
   IEC1010-1 (2001): EN61010-1 (2001)  —  — 
   Overvoltage Category IV 600V and 
   Category III 1000V, Pollution Degree 2
— —
— —
— —
 To Order Visit omega.com/hhm-ma1500 for Pricing and Details
 Model No.  Description 
 HHM-MA1500  1500A true RMS AC/DC clamp meter with non-contact voltage
Comes complete with test leads,Type K bead wire temperature probe, 9V battery, carrying case and operator’s manual. 
Ordering Example: HHM-MA1500, 1500A true RMS AC/DC clamp meter with non-contact voltage.