Omega Products HHM-EX623 User Manual

400 A Dual Input Clamp Meter
With Non-Contact Infrared Thermometer and Voltage
HHM-EX623
U True RMS Measurements for Accurate
AC Voltage and Current Measurements
Differential Temperature Function (T1, T2, T1-T2)
U Built-In Non-Contact Voltage Detector
with LED Alert
U DC µA Multimeter Function for HVAC
Flame Rod Current Measurements
U Data Hold Plus Fast Peak Hold of
Current Surges During Motor Startup
U 40,000 Count Multimeter Functions for
DC Voltage, Resistance, Capacitance, and Frequency for High Resolution Over Wider Ranges
U Measures Motor Capacitors to 40,000µF U 32 mm (1.25") Jaw Opening for
Conductors up to 500MCM
U Rugged Double Molded Housing U Auto Power Off with Audible Alert and
Disable Function
U Autoranging with Manual Override U Built-In Non-Contact Infrared
Thermometer with Laser Pointer for Locating Hot Spots
U 8 to 1 Distance to Target Ratio U DC Current Function Ideal for
Automotive, Heavy Equipment and Marine Applications
HHM-EX623
shown actual size.
The HHM-EX623 is a True RMS Clamp Meter with built-in dual thermocouple inputs for T1, T2, and T1-T2 differential temperature measurement and non-contact infrared thermometer. This meter measures AC Current, DC current, AC/DC voltage, resistance, capacitance, frequency, diode test, duty cycle and continuity and also features a non-contact voltage detector. The double molded case is designed for heavy-duty use. This meter is shipped fully tested and calibrated, and with proper use, will provide years of reliable service.
FREE Thermocouple Included!
All models include a free 900 mm (36") Type K insulated beaded wire thermocouple with subminiature connector and wire spool caddy.
Order a Spare! Model No. SC-GG-K-30-36
Q
Q-1
Dual Type K inputs for taking differential temperature readings needed for superheat measurements.
Built-in infrared thermometer for quick and safe non-contact temperature measurements. Find hot spots fast!
SPECIFICATIONS
AC/DC Current: 400.0A Max Resolution: 10 mA Basic ACA Accuracy: ±1.5% AC/DC Voltage (Max Resolution):
600V (0.1 mV)/600V (0.01 mV)
DC µA Current : 4000 μA (0.01 μA) Resistance (Max Resolution): 40.000 MΩ (0.01Ω) Capacitance (Max Resolution): 10pF to 40,000μF (0.01nF) Frequency (Max Resolution): 40 MHz (0.001Hz) Temperature (Type K): -58 to 1832°F (-50 to 1000°C) Duty Cycle: 0.5 to 99.0% Temperature Infrared (IR): -50 to 270°C (-58 to 518°F) IR Spectral Response: 6 to 16 μm IR Emissivity: 0.95 fixed IR Distance Ratio: 8:1 Laser Pointer: Class 2 laser < 1mW power; wavelength is
630 to 670 nm
Clamp Jaw Opening: 32 mm (1.25") approx. Display: Dual 40,000/4000 count backlit LCD Non-Contact Voltage: 100 to 600 Vac Continuity Check: Threshold 50 Ω; test current < 0.5mA Diode Test: Test current of 0.3 mA typical Open Circuit Voltage: 2.8 Vdc typical
Low Battery Indication: Battery symbol is displayed Over-Range Indication: ‘OL’ display Measurement Rate: 2 readings per second, nominal Peak Detector: >1ms Fuse: 500 mA, ceramic fast blow Input Impedance: 10M Ω (Vdc and Vac) AC Bandwidth: 50 to 400 Hz (Aac and VAC) AC Response: True RMS (Aac and Vac) Crest Factor: 3.0 in 40A and 400A ranges, 1.4 in
1000A range (50/60 Hz and 5% to 100% of range)
Operating Temperature: 5 to 40°C (41 to 104°F) Storage Temperature: -20 to 60°C (-4 to 140°F) Operating Humidity: Max 80% up to 31°C (87°F)
decreasing linearly to 50% at 40°C (104°F)
Storage Humidity: <80% Operating Altitude: 2000 m (7000') maximum Battery: One (1) 9V battery included (NEDA 1604) Auto Power Off: After approx. 30 minutes, with disable Dimensions: 229 H x 80 W x 49 mm D (9 x 3.1 x 1.9") Weight: 303 g (10.7 oz) Safety: For indoor use and in accordance with the
requirements for double insulation to IEC1010-1 (2001): EN61010-1 (2001) Overvoltage Category III 600V and Category II 1000V, Pollution Degree 2
To Order Visit omega.com/hhm-ex623 for Pricing and Details
Model No. Description HHM-EX623 Built-in dual thermocouple inputs for T1, T2, and T1-T2 differential temperature measurement
Comes complete with CAT III-600 V, double molded, test leads, 9V battery, two general purpose Type K bead wire probes, carrying case and operator’s manual.
Ordering Example: HHM-EX623, built-in dual thermocouple inputs for T1, T2, and T1-T2 differential temperature measurement
Q-2
Loading...