It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification
of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct but OMEGA Engineering, Inc. accepts no liability for any errors it contains,
and reserves the right to alter specifications without notice.
WARNING: These products are not designed for use in, and should not be used for, patient connected application.
For immediate technical or application assistance:
Servicing North America:
SM
SM
Servicing Europe:
TM
Internet e-mail
info@omega.com
Tel: (95) 800-TC-OMEGA
FAX: (95) 203-359-7807
SM
SAFETY INFORMATION
The following safety information must be observed to ensure maximum
personal safety during the operation of this meter:
1. Do not use the meter if the meter or test leads look damaged, or if you
suspect that the meter is not operating properly.
2. This meter is not recommended for high voltage industrial use; for example,
not for measurements of 440 VAC or 600 VAC industrial power mains. The
unit is intended for use with low energy circuits to 1000VDC or 750VAC or
high energy circuit to 250 VAC or DC. Accidental misuse by connection
across a high voltage, high energy power source when the meter is set up
for mA measurement may be very hazardous.
3. Turn off power to the circuit under test before cutting, unsoldering, or
breaking the circuit. Small amounts of current can be dangerous.
4. Use caution when working above 60V dc or 30V ac rms. Such voltages pose
a shock hazard.
5. When Using the probes, keep your fingers behind the finger guards on the
probes.
6. Measuring voltage which exceeds the limits of the multimeter may damage
the meter and expose the operator to a shock hazard. Always recognize the
meter voltage limits as stated on the front of the meter.
7. If the equipment is used in a manner not specified by the manufacturer, the
protection provided the equipment may be impaired.
1
SPECIFICATIONS
Display: 3¾ digit liquid crystal display (LCD) with a maximum reading of 3999.
Polarity: Automatic, positive implied, negative polarity indication.
Overrange: (OL) or (-OL) is displayed.
Zero: Automatic.
Low battery indication: the "" is displayed when the battery voltage drops
below the operating level.
Measurement rate: 1.5 times per second, nominal.
Analog bar graph: 41 segments with measurements 12 times per second.
Operating Environment: 0°C to 50°C at < 70% relative humidity.
Storage Temperature: -20°C to 60°C, 0 to 80% R.H. with battery removed
from meter.
Accuracy: Stated accuracy at 23°C ± 5°C, <75% relative humidity.
Safety: According to EN61010-1 protection class II overvoltage category
(CAT II 600V) pollution degree 2.
Power: single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22.
Battery life: 100 hours typical.
Dimensions: 192mm (H) x 91mm (W) x 52.5mm (D).
Weight: 301g including battery.
Accessories: One pair test leads, One spare fuse installed, 9V battery and
Operating Instructions.
2
DC VOLTS
Ranges: 400mV,4V,40V,400V,600V
Resolution: 100µV
Accuracy: ±(0.25%rdg + 1dgt)
Input impedance: 10MW
Overload protection: 500VDC or AC rms on 400mV range