HOT WIRE ANEMOMETER
WITH REAL TIME DATA LOGGER
HHF-SD1
U Slim Probe, Ideal for
Grilles and Diffusers
U Type K or J
Thermocouple Input
U Real Time SD Memory
Card Data Logger
U LCD with Green
Light Backlighting
U Velocity and Air
Temperature
Measurements
U RS232/USB Interface
(Optional Cable)
Type K
thermocouple
(included).
Telescoping
probe (included).
C
The Omega® HHF-SD1 combination
hot wire and standard thermistor
anemometer with SD card data
logger has multiple features that
make it suitable to use in such
applications as environmental
testing, balancing of fans/motors/
blowers, air conveyors, clean rooms,
and flow hoods. What sets the
HHF-SD1 apart from other hot wire
anemometers is that it incorporates
a real-time SD card data logger.
The HHF-SD1 measures velocity,
and air temperature, and has an
input socket that accepts a Type J
or K thermocouple that can be used
as a highly accurate thermometer.
The integrated hot wire and standard
thermistors provide fast and accurate
readings-even at low velocities. The
HHF-SD1 is innovative and easy to
operate. Download data from the
SD card into an Excel spreadsheet
without the need for special software.
Free Thermocouple
Included!
This model includes a free 1 m (40”)
Type K insulated beaded wire thermocouple
with subminiature connector and wire spool
caddy. Order a Spare!
Model No. SC-GG-K-30-36
2GB-SD card
(included)
HHF-SD1
C-1

SPECIFICATIONS
Display: 52 x 38 mm (2.05 x 1.5") LCD
with green backlight (on/off)
Measurement Units:
Velocity: m/s, km/h, ft/min,
knots, mile/hr
Temperature: ºC or ºF
Sensor Construction:
Glass bead thermistor
Sampling Time:
Auto: 1 to 3600 seconds
Manual: Push the data logger button
once; will save data one time
Memory Card: SD memory card
Temperature Compensation:
Automatic
Display Update: At 1 second
Data Output (RS232/USB):
With optional cable/software
Operating Temperature: 0 to 50ºC
(32 to 122ºF)
Operating Humidity: Less than
85% RH
Power: 6 “AAA” alkaline or heavy-duty
batteries (included), or 9V power
adaptor (optional)
Current Draw: 15 mA DC (without SD
card or backlight), 36 mA (all functions)
Weight: 515 g (1.13 lb)
Dimensions:
Instrument: 203 L x 76 W x 38 mm D
(8 x 3 x 1.50")
Probe: 12 mm (0.47") diameter,
280 to 940 mm (11 to 37") length
Air Temperature Measuring Range:
0 to 50ºC (32 to 122ºF)
Resolution: 0.1ºC (0.1ºF)
Accuracy: ± 0.8ºC (1.5ºF)
HHF-SD1 comes complete
with hard carrying case,
Type K thermocouple,
telescoping probe, SD card,
and operator’s manul.
Accuracy
Measurement Range Resolution (Reading)
m/s 0.2 to 5 m/s 0.01 m/s ± (5% + a)
5.1 to 25 m/s 0.1 m/s reading
km/h 0.70 to 18 km/h 0.01 km/h
18 to 72 km/h 0.1 km/h or
mile/h 0.50 to 11.20 mph 0.01 mph ± (1% + a)
(mph) 11.2 to 44.7 mph 0.1 mph full scale
knot 0.40 to 9.70 knot 0.01 knot (whichever
9.7 to 38.8 knot 0.1 knot is greater
ft/min 40 to 3940 ft/min 1 ft/min
(a = 0.1 m/s, 0.3 km/h, 0.2 mile/h, 0.2 knot, 20 ft/min)
Note: m/s = meters per second, km/h = kilometers per hour, ft/min = feet per minute,
mile/h = miles per hour, knot = nautical miles per hour (international knot)
±(5% + a) reading
or ±(1% + a)
full scale
whichever
is greater
Type K/J Thermometer (Sensor Sold Separately)
Sensor Resolution Range Accuracy
0.1ºC -50 to 1300ºC ±(0.4% + 0.5ºC)
-50.1 to -100ºC ±(0.4% + 1ºC)
0.1ºF -58 to 2372ºF ±(0.4% + 1ºF)
-58.1 to -148ºF ±(0.4% + 1.8ºF)
0.1ºC -50 to 1200ºC ±(0.4% + 0.5ºC)
-50.1 to -100ºC ±(0.4% + 1ºC)
0.1ºF -58 to 2192ºF ±(0.4% + 1ºF)
-58.1 to -148ºF ±(0.4% + 1.8ºF)
To Order Visit omega.com/hhf-sd1 for Pricing and Details
Model No. Description
HHF-SD1 Data logging airflow meter with SD card–hot wire type
Accessories
Model No. Description
HHF-SD1-RP Replacement hot wire probe
SW-U101-WIN Software for data logging from meters, with USB and RS232 cables
HC-SD Replacement hard carrying case
SC-SD Soft carrying case
ADAPTER-SD AC adaptor
USB-SD Spare USB cable (SW-U101-WIN software required)
RS232-SD Spare RS232 cable (SW-U101-WIN software required)
2GB-SD Spare 2 GB SD memory card
Comes complete with telescoping probe, 2 GB SD card, Type K thermocouple, hard carrying case, 6 “AAA” batteries and operator’s manual.
Ordering Example: HHF-SD1 data logging airflow meter with SD card, and ADAPTER-SD AC adaptor.
C-2