Hot Wire Anemometer WitH
reAl time DAtA logger
HHF2005HW
†
Optional
U Real Time Data Logger
Records Year, Month,
Date, Hour, Minute and
Second—Up to 16,000
Records
U Hot Wire Technology
for High Precision,
Low Velocity Air
Measurements
U RS232 Serial Interface
and Software Available
U Battery Powered Meter
Includes Hard Carrying
Case for Easy Portability
U Slim Telescopic Probe
is Ideal For Grilles and
Diffusers
U Jumbo LCD With
Multiple Displays Can be
Adjusted for Brightness
U Adjustable Sampling
Time, Zero Adjust and
Data Hold Features
U Accepts Type J or K
Thermocouples
The HHF2005HW hot wire
anemometer with real time data
logger has multiple features and
an RS232 computer interface that
make it suitable to use in such
applications as environmental
testing, balancing of fans/motors/
blowers, air conveyors, clean
rooms and flow hoods. What
sets the HHF2005HW apart from
other hot wire anemometers is
that it incorporates a real-time
data logger that can store up to
16,000 entries. The HHF2005HW
measures velocity, and air
temperature, and has an input
probe socket that accepts a Type
J or K thermocouple that can
be used as a highly accurate
thermometer. By entering the area
into the instrument and measuring
the velocity, the HHF2005HW can
even determine the volume of air
flow. The integrated hot wire and
standard thermistors provide fast
and accurate readings—even at low
velocities. For added convenience,
the HHF2005HW is battery
C-7
HHF2005HW
powered, has auto power off and
low battery warning features. A
hard carrying case is included, to
make portability simple.
†
Refer to the footnote on next page for
NIST calibration ordering information.
SPECIFICATIONS
Display Units: m/s, km/h, mile/h, knot,
ft/min, CMM, CFM, °C, °F
Operating Temperature: 0 to 50°C
(32 to 122°F)
Max Humidity: Less than 80% relative
humidity (non-condensing)
Sampling Time: 2 sec to 8 hours,
59 min, 59 sec
Power Supply: 4 “AA” batteries
(included)
Current: Approx 21.5 mA dc (70 mA dc
with hot wire probe)
Weight: Approx 515 g (1.13 lb)
Dimensions:
Instrument: 203 x 76 x 38 mm
(8.0 x 3.0 x 1.5")
Telescopic Probe: 12 mm (0.5") dia,
280 to 940 mm (11.0 to 37.0") length
LCD Display: 58 x 34 mm (2.3 x 1.3")
Hard carrying
case, operators
manual, and 4 “AA”
batteries included.
Measurement Range Resolution Accuracy
m/s 0.2 to 20 m/s 0.1 m/s
km/hr 0.7 to 72 km/hr 0.1 km/hr
mile/hr 0.5 to 44.7 mile/hr 0.1 mile/hr
knot 0.4 to 38.8 knot 0.1 knots
ft/min 40-3940 ft/min 1 ft/min
Air temp (˚C) 0 to 50°C 0.1°C ± 0.8°C
Air temp (˚F) 32 to 122°F 0.1°F ± 1.5°F
-100.0 to 1100°C ± (0.2% + 0.5°C)
Thermometer
-50.1 to -100°C ± (0.2% + 1°C)
(Type J
-58.0 to 2012°F ± (0.2% + 1°F)
thermocouple)
-58.1 to -148°F ± (0.2% + 1.8°F)
-50.0 to 1300°C ± (0.2% + 0.5°C)
Thermometer
-50.1 to -100°C ± (0.2% + 1°C)
(Type K
-58.0 to 2372°F ± (0.2% + 1°F)
thermocouple)
-58.1 to -148°F ± (0.2% + 1.8˚F)
Measurement Range Resolution Area
CMM 0 to 36,000 CMM 0.001-1 CMM 0.001 to 30.0 m
CFM 0 to 1,271,200 CFM 0.01-100 CFM 0.01 to 322.91 ft
0.1°C
0.1°F
0.1°C
0.1°F
± (10% + lsd)
full scale
C
2
2
To Order Visit omega.com/hhf2005hw for Pricing and Details
Model No. Description
HHF2005HW Hot wire anemometer with data logger
HHF2005HW-RP Replacement probe for HHF2005HW
SW-U101-WIN Data logging software
MN1500-4 4 “AA” replacement batteries
CAL-3-FLOW† NIST traceable 4-point calibration certificate
Comes complete with sensor, 4 “AA” batteries, hard carrying case and operator’s manual.
Ordering Example: HHF2005HW, hot wire anemometer with data logger.
C-8