HHF2005, $539, shown smaller actual size.
The HHF2005 anemometer with real time data logger has multiple features and an RS232 computer interface that make it suitable to use in a variety of HVAC applications, such as environmental testing, flow hoods and wind speed measurements. What sets the HHF2005 apart from other anemometers is that it incorporates
a real-time data logger that can store up to 16,000 entries. The HHF2005 measures velocity and air temperature, and has an input probe socket that accepts a Type J or K thermocouple that can be used as a highly accurate thermometer. By entering the area into the instrument and measuring the velocity, the HHF2005 can even
determine the volume of air flow. The integrated thermistor provides fast and accurate readings—at low or high velocities. For added convenience, the HHF2005 is battery powered, has auto power off and low battery warning features. A hard carrying case is included to make portability simple.
ANEMOMETER WITH REAL TIME DATA LOGGER
Real Time Data
Logger Records Year, Month, Date, Hour, Minute and Second—Up to 16,000 Records
Heavy Duty Metal Van
Gives Very Accurate Low and High Velocity Air Measurements
Battery Powered
Meter Includes Hard Carrying Case For Easy Portability
Jumbo LCD With
Multiple Displays Can be Adjusted For Brightness
Adjustable Sampling
Time and Data Hold Features
Accepts Type J or K
Thermocouple
C-14
C
Measurement Range Resolution Accuracy
m/s 0.4 to 30.0 m/s 0.1 m/s ± (2% + 0.2 m/s)
km/hr 1.4 to 108.0 km/hr 0.1 km/hr ± (2% + 0.8 km/hr)
mile/hr 0.9 to 67.0 mile/hr 0.1 mile/hr ± (2% + 0.4 mile/hr)
knot 0.8 to 58.3 knot 0.1 knots ± (2% + 0.4 knot)
ft/min 80 to 5910 ft/min 1 ft/min ± (2% + 40 ft/min) Air temp (˚C) 0 to 50°C 0.1°C ± 0.8°C Air temp (˚F) 32 to 122°F 0.1°F ± 1.5°F
-100.0 to 1100°C ± (0.2% + 0.5°C)
-50.1 to -100°C ± (0.2% + 1°C)
-58.0 to 2012°F ± (0. 2% + 1°F)
-58.1 to -148°F ± (0.2% + 1.8°F)
-50.0 to 1300°C ± (0.2% + 0.5°C)
-50.1 to -100°C ± (0.2% + 1°C)
-58.0 to 2372°F ± (0.2% + 1°F)
-58.1 to -148°F ± (0.2% + 1.8°F)
Hard carrying case, operators manual, and 4 “AA” batteries included.
Measurement Range Resolution Area
CMM 0 to 54,000 CMM 0.001-1 CMM 0.001 to 30.0 m
2
CFM 0 to 1,908,300 CFM 0.01-100 CFM 0.01 to 322.91 ft
2
Thermometer
(Type J
thermocouple)
Thermometer
(Type K
thermocouple)
0.1°C
0.1°F
0.1°C
0.1°F
Comes complete with operator’s manual, 4 “AA” batteries and hard carrying case. Ordering Example: HHF2005, vane anemometer with data logger, $539.
AVAILABLE FOR FAST DELIVERY!
SPECIFICATIONS
Display Units: m/s, km/h, mile/h, knot,
ft/min, CMM, CFM, °C, °F Operating Temperature: 0 to 50°C
(32 to 122°F) Max Humidity: Less than 80% relative
humidity (non-condensing) Sampling Time: 2 sec to 8 hours,
59 min, 59 sec Power Supply: 4 “AA” batteries
(included) Current: Approx 21.5 mA dc (27.5 mA
dc with vane)
Weight: Approx 515 g (1.13 lb) Dimensions:
Instrument: 203 x 76 x 38 mm
(8.0 x 3.0 x 1.5")
Metal Vane: 72 mm (2.8") dia LCD Display: 58 x 34 mm (2.3 x 1.3")
To Order (Specify Model Number)
Model No. Price Description HHF2005 $539 Vane anemometer with data logger HHF2005-RP 200 Replacement vane for HHF2005 SWCABLE 115 Data logging software for the HHF2005 series with cables MN1500-4 3 4 “AA” replacement batteries
Recommended Reference Book:
Heating, Ventilating and Air Conditioning,
MS-1001, $180.
Visit omega.com/bobi for Additional Books
±10% +1 lsd
One Omega Drive | Stamford, CT 06907 | 1-888-TC-OMEGA (1-888-826-6342) | info@omega.com
EPG05
www.omega.com
UNITED KINGDOM
www. omega.co.uk
Manchester, England
0800-488-488
UNITED STATES
www.omega.com
1-800-TC-OMEGA
Stamford, CT.
CANADA
www.omega.ca
Laval(Quebec)
1-800-TC-OMEGA
GERMANY
www.omega.de
Deckenpfronn, Germany
0800-8266342
Karviná, Czech Republic
FRANCE
www.omega.fr
Guyancourt, France
088-466-342
CZECH REPUBLIC
www.omegaeng.cz
596-311-899
BENELUX
www.omega.nl
Amstelveen, NL 0800-099-33-44
More than 100,000 Products Available!
Temperature
Calibrators, Connectors, General Test and Measurement Instruments, Glass Bulb Thermometers, Handheld Instruments for Temperature Measurement, Ice Point References, Indicating Labels, Crayons, Cements and Lacquers, Infrared Temperature Measurement Instruments, Recorders Relative Humidity Measurement Instruments, RTD Probes, Elements and Assemblies, Temperature & Process Meters, Timers and Counters, Temperature and Process Controllers and Power Switching Devices, Thermistor Elements, Probes and Assemblies,Thermocouples Thermowells and Head and Well Assemblies, Transmitters, Wire
Flow and Level
Air Velocity Indicators, Doppler Flowmeters, Level Measurement, Magnetic Flowmeters, Mass Flowmeters, Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area Flowmeters, Vortex Shedding Flowmeters
pH and Conductivity
Conductivity Instrumentation, Dissolved Oxygen Instrumentation, Environmental Instrumentation, pH Electrodes and Instruments, Water and Soil Analysis Instrumentation
Data Acquisition
Auto-Dialers and Alarm Monitoring Systems, Communication Products and Converters, Data Acquisition and Analysis Software, Data Loggers Plug-in Cards, Signal Conditioners, USB, RS232, RS485 and Parallel Port Data Acquisition Systems, Wireless Transmitters and Receivers
Pressure, Strain and Force
Displacement Transducers, Dynamic Measurement Force Sensors, Instrumentation for Pressure and Strain Measurements, Load Cells, Pressure Gauges, Pressure Reference Section, Pressure Switches, Pressure Transducers, Proximity Transducers, Regulators, Strain Gages, Torque Transducers, Valves
Heaters
Band Heaters, Cartridge Heaters, Circulation Heaters, Comfort Heaters, Controllers, Meters and Switching Devices, Flexible Heaters, General Test and Measurement Instruments, Heater Hook-up Wire, Heating Cable Systems, Immersion Heaters, Process Air and Duct, Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters
click here to go to the omega.com home page
Loading...