Omega Products HH804 Installation Manual

1 2
HH804
Third Display
4
7
10
12
8
11
M4730/0410
Shop online
at: omega.com e
-
mail: info@omega.com
INSTRUCTION
HH804 HH804U
SHEET
For latest product manuals: omegamanual.info
Main Display
Second Display
1
OMEGAnet

On-Line Service
omega.com
Internet e-mail
info@omega.com
Servicing North America:
U.S.A: OMEGA Engineering, Inc.
ISO 9001
ISO 9001 One Omega Drive, P.O. Box 4047
ISO 9001ISO 9001 Certified
Certified Stamford, CT 06907-0047 USA
CertifiedCertified
Toll-Free: 1-800-826-6342 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com
Canada: 976 Bergar, Laval (Quebec), Canada H7L 5A1 Toll-Free: 1-800-826-6342 Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca
For immediate technical or application assistance:
U.S.A Sales Service: 1-800-826-6342/1-800-TC-OMEGA and Customer Service: 1-800-622-2378/1-800-622-BEST Canada:
Mexico: En Espanol: (001) 203-359-7803
FAX: (001) 203-359-7807 info@omega.com.mx e-mail: espanol@omega.com
Engineering Service: 1-800-872-9436/1-800-USA-WHEN®
®
®
Servicing Europe:
Benelux: Managed by the United Kingdom Office Toll-Free: 0800 099 3344 Tel: +31 20 347 21 21 FAX: +31 20 643 46 43 e-mail: sales@omegaeng.nl
Czech Frystatska 184, 733 01 Karviná, Czech Republic Republic: Toll-Free: 0800-1-66342 Tel: +420-59-6311899 FAX: +420-59-6311114
2
3
5
6
9
e-mail: info@omegashop.cz France: Managed by the United Kingdom Office
Toll-Free: 0800 466 342 Tel: +33 (0) 161 37 29 00 FAX: +33 (0) 130 57 54 27 e-mail: sales@omega.fr
Germany/ Daimlerstrasse 26, D-75392 Deckenpfronn, Germany Austria: Tel: + 49 (0)7056 9398-0 FAX: +49 (0)7056 9398-29
Toll Free in Germany: 0800 639 7678 e-mail: info@omega.de
United OMEGA Engineering Ltd. Kingdom: One Omega Drive,
ISO 900
ISO 9001111 River Bend Technology Centre, Northbank,
ISO 900ISO 900 Certified
Certified Irlam, Manchester M44 5BD England
CertifiedCertified
Toll-Free: 0800-488-488 Tel: +44 (0)161 777-6611 FAX: +44 (0)161 777-6622 e-mail: sales@omega.co.uk
It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification. The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, human applications.
INTRODUCTION
This instrument is a 4½ digit, compact-sized portable digital thermometer designed to use external 100 Platinum RTD as temperature sensor. Temperature indication follows Reference Temperature/Resistance Tables (Pt385 for Euro­pean Curve, Alpha=.00385. Pt3926 for American Curve, Alpha=.003926. Pt3916 for Japan Curve, Alpha=.003916.)
SAFETY INFORMATION
It is recommended that you read the safety and operation instructions before using the thermometer.
WARNING
To avoid electrical shock, do not use this instrument
when working voltages at the measurement surface
over 24V AC or DC.
WARNING
To avoid damage or burns, do not make temperature
measurement in microwave ovens.
SPECIFICATIONS
ELECTRICAL
Temperature Scale: Measurement Range:
Pt385(100) -200°C to 800°C, (-328°F to 1472°F) Pt3916/Pt3926(100) -200°C to 630°C, (-328°F to 1166°F)
Resolution: 0.1°C or 0.2°F Accuracy:
Accuracy is specified for operating temperatures over the range of 18°C to 28°C (64°F to 82°F), for 1 year, not includ­ing RTD probe error. ±(0.05% rdg + 0.2°C) on °C scale ±(0.05% rdg + 0.4°F) on °F scale
Temperature Coefficient:
0.1 times the applicable accuracy specification per °C from 0°C to 18°C and 28°C to 50°C (32°F to 64°F and 82°F to 122°F).
Input Protection:
24V dc or 24V ac rms maximum input voltage on any com­bination of input pins.
Maximum Differential Common Mode Voltage (Maxi­mum Voltage between T1 and T2 during measurement):
1volt.
Reading Rate: 1 time per second. Input Connector:
Accepts for RTD 3 wires or 4 wires subminiature 4-Prong type connectors (flat blades spaced 7.9mm, center to center).
ENVIRONMENTAL
Ambient Operating Ranges:
0°C to 50°C (32°F to 122°F) <80% R.H.
Storage Temperature:
-20°C to 60°C (-4°F to 140°F) <70% R.H.
GENERAL
Display: 4½ digit liquid crystal display (LCD) with maxi-
mum reading of 19999. Overload: “----.-” or “OL” is display.
Celsius or Fahrenheit user-selectable
Battery: 1.5V x 4 PCS (SIZE AAA) UM-4 R03. Battery Life: 200 hours typical with carbon zinc battery.
Reading Rate: 1 time per second. Auto power off: 30 minutes, press power key to resume
operation.
Dimensions: 160mm(H) x83mm(W) x 38mm(D). Weight: Approx. 260g including batteries. Wire Communication Protocol:
19200 baud rate. (HH804U) External Connections: (HH804U)
1. USB Port
2. DC power JACK(12V)
OPERATING INSTRUCTIONS
1.
“ ”
Power Button
The “ ” key turns the thermometer on or off. In the SET mode cannot be powered off. Exit SET mode to power off.
APO function mode
Press “ ” power key for more than 6 seconds to disable the auto-power function. The display will show “APO OFF”.
2. °C/°F Selecting the Temperature Scale (Main display)
Reading the main displayed in either degrees Celsius(°C) or degrees Fahrenheit(°F). When the thermometer is turned on, it is set to the temperature scale that was in use when the thermometer was last turned off. To change the temperature scale, press the “°C/°F” key.
3. “ ” Display Back-Light
Press the “ ” key to turn on or turn off the Back-Light.
4. “T1 T2/T1-T2” Main display Input Selection
The input selection indicates which input is selected for main display; T1 probe, T2 probe or the difference between the two probes (T1-T2). When the thermometer is turned on, it is set to T1, when main display input selected T1, then T1 input can select alternate of probe by pressing Pt385/Pt3926/Pt3916 key switch.
5. “TYPE”(Pt385/Pt3926/Pt3916) Input RTD Probe Select (only Main display)
The “TYPE” key switches the T1 input to select the Pt385, Pt3926 or Pt3916 RTD probe as input, when main display input selected T1. When the thermometer is turned on, it is set to the probe selected that was in use when the thermome­ter was last turned off.
6. “MIN/MAX” with Time record mode (only Main display)
Press “MIN/MAX” key to enter the MIN MAX Recording mode, (displays the Maximum reading with time, Minimum reading with time and Average reading stored in record mode). In the this mode the automatic power-off feature is disabled and “ ” key, “°C/°F” key, “REL” key, “SET” key, “Hi/Lo Limits” key and main display “T1 T2 T1-T2” key, “TYPE” key are disabled. The beeper emits a tone when a new minimum or maximum value is recorded. Press “MIN/MAX” key to cycle through the MAX, MIN and AVG readings. If an overload is recorded, the averaging function is stopped. In this mode, press the “HOLD” key to stop the recording of readings, all values are held, press again to restart recording.
To prevent accidental loss of MIN, MAX and AVG data, this
TEMPERATURE
Made in Taiwan
mode can only be cancelled by pressing and holding the “MIN/MAX” key for 2 seconds. All recorded readings are erased.
7. REL Relative mode (only Main display)
Press the “REL” key to enter the relative mode, zero the display, and store the displayed Reading as a reference value. REL is shown on the display. Press “REL” key again to exit the relative mode. The relative reference value can also be entered by the user. (See “SET mode” later in this manual). When the desired relative value has been entered, press “REL” key to enter the relative mode and than press “SET” key use the entered relative value as a reference value. Press “REL” key again to exit the relative mode. In the relative mode, the value (can not >±1999.9 counts) shown on the LCD is always the difference between the stored reference and the present reading.
8. HOLD mode (only Main display)
Press the “HOLD” key to enter the Data Hold mode, the “HOLD” annunciator is displayed. When HOLD mode is selected, the thermometer held the present readings and stops all further measurements. Press the “HOLD” key again to cancel HOLD mode causing thermometer to resume taking measurements. In the MIN/MAX recording mode, press “HOLD” key to stop the recording. Press “HOLD” key again to resume recording. (Previously recorded read are not erased).
9. SET mode (Relative value set, Time set and Hi/Lo Limits value set)
9.1 Press the “SET” key to enter relative values SET mode
(Press “ENTER” key to skip setting relative value). = = = =.= is displayed on the main display. The relative value is entered via overlay numbers, press overlay “ENTER” key to store the relative value, and advance to elapsed time set mode.
9.2 Elapsed time set mode, (Press ENTER key to skip
Elapsed time set mode) =.= = = : = = is displayed in sec­ond and third display. Time (hours, minutes, seconds) value is entered via overlay numbers, press overlay “ENTER” key to store time value. Elapsed time starts from set time value.
9.3 Hi Limit value set mode, (Press “ENTER” key to skip Hi
Limit value set mode), = = = =.= is displayed in main display, Hi Limit value is entered via overlay numbers, then press “ENTER” key to store the Hi Limit value. = = = =.= is displayed in main display, Lo Limit value is en­tered via overlay numbers, then press overlay “ENTER” key to store the Lo Limit value and exit SET mode.
9.4 When the thermometer is turned on it uses the relative
value and Hi/Lo Limits values that were entered when thermometer was last in use.
10. T1/T2 T1-T2 second display Input Selection
The input selection indicates which input is selected for second display; T1 probe, T2 probe or the difference between the two probes (T1-T2), when the thermometer is turned on, it is set to T2 input can select alternate of probe by second display Pt385/Pt3926/Pt3916 key switch.
11. TYPE(Pt385/Pt3926/Pt3916) Input RTD Probe
select (second display)
The Pt385/Pt3926 key switches the T2 input to select the Pt385, Pt3926 or Pt3916 RTD probe as input, when second display input selected T2. When the thermometer is turned on, it is set to the RTD selected that was in use when the ther­mometer was last turned off.
12. Hi/Lo Limits mode (only Main display)
Press “Hi/Lo Limits” key to enter the Hi/Lo Limits compara­tive mode. When the input temperature value exceeds the Hi or Lo Limits value, the beeper emits a continuous or pulsed tone. Press “Hi/Lo Limits” key again to exit the Hi/Lo Limits mode.
RTD PROBE CONNECTION
P/N: 14061-0800-9 MINI DIN PLUG
Rear view
Front view
3 Wires 4 Wires
TEMPERATURE VSRESISTANCE TABLE (ITS90)
°C Pt385 Pt3926 Pt3916
-200°C 18.521 16.996 17.057
-100°C 60.256 59.479 59.565 0°C 100.000 100.000 100.000
100°C 138.505 139.272 139.171 200°C 175.856 177.362 177.155 300°C 212.052 214.275 213.957 400°C 247.092 250.018 249.584 500°C 280.977 284.591 284.036 600°C 313.708 317.994 317.313 700°C 345.280 - ­800°C 375.700 - -
OPERATOR MAINTENANCE
To avoid possible electrical shock, disconnect the
thermocouple connectors from the thermometer before
Battery Replacement
1. Power is supplied by 4pcs 1.5V (AAA SIZE) UM-4 R03.
2. The “ ” appears on the LCD display when replacement is needed. To replace battery remove screw from back of meter and lift off the battery cover.
3. Remove the battery from battery contacts and replace.
4. When not in use for long periods remove battery.
5. Do not store in locations with high temperatures, or high
WARNING
removing the cover.
humidity.
Cleaning
Periodically wipe the case with a damp cloth and detergent, do not use abrasives or solvents.
*Software Operation manual is on the Software disk.
WARRANTY / DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components which wear is not warranted, include but are not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESS OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY / DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
Direct all warranty and repair requests / inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence. The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.
FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA:
1. Purchase Order number under which the product was PURCHASED,
2. Model and serial number of the product under warranty, and
3. Repair instructions and/or specific problems relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in tech­nology and engineering. OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
RETURN REQUESTS / INQUIRIES
FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA:
1. Purchase Order number to cover the COST of the repair,
2. Model and serial number of the product, and
3. Repair instructions and/or specific problems relative to the product.
© Copyright 2010 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.
Where Do I Find Everything I Need
for Process Measurement
and Control?
OMEGA…Of Course!
Shop online at omega.com
Thermocouple, RTD & Thermistor Probes,
Connectors, Panels & Assemblies Wire: Thermocouple, RTD & Thermistor Calibrators & Ice Point References Recorders, Controllers & Process Monitors Infrared Pyrometers
PRESSURE, STRAIN AND FORCE
Transducers & Strain Gages Load Cells & Pressure Gages Displacement Transducers Instrumentation & Accessories
FLOW/LEVEL
Rotameters, Gas Mass Flowmeters & Flow
Computers Air Velocity Indicators Turbine/Paddlewheel Systems Totalizers & Batch Controllers
pH/CONDUCTIVITY
pH Electrodes, Testers & Accessories Benchtop/Laboratory Meters Controllers, Calibrators, Simulators & Pumps Industrial pH & Conductivity Equipment
DATA ACQUISITION
Data Acquisition & Engineering Software Communications-Based Acquisition Systems Plug-in Cards for Apple, IBM & Compatibles Datalogging Systems Recorders, Printers & Plotters
HEATERS
Heating Cable Cartridge & Strip Heaters Immersion & Band Heaters Flexible Heaters Laboratory Heaters
ENVIRONMENTAL MONITORING AND CONTROL
Metering & Control Instrumentation Refractometers Pumps & Tubing Air, Soil & Water Monitors Industrial Water & Wastewater Treatment pH, Conductivity & Dissolved Oxygen
Instruments
Loading...