Omega Products HH550 Installation Manual

CONTENTS
Title page
1. SAFET Y I N F O R M A T I O N................................................................................................1
2. SPECIFICATION.............................................................................................................2
2-1 General Specification........................................................................................... 2
2-2 Electrical Specification..........................................................................................5
3. PARTS & C O N T R OL S....................................................................................................6
3-1 The Name of Each Parts and Positions................................................................6
3-4 ACV、DCV and DCA Test Setting
3-5 UNIT Setting Step..............................................................................................10
3-6 ALARM Setting Step........................................................................................... 10
3-7 Real Time Clock , Time/ Date Setting Step........................................................11
3-8 Record/Print Start Time, Stop Time, Interval Time Setting Step......................... 11
3-9 Print Mode Setting Step...................................................................................... 12
3-10 Clear Record Step............................................................................................12
3-11 Disable St art、Stop、Intv and Setting Step.................................................... 12
3-12 Decimal Point Setting Step...............................................................................12
3-13 Consecutive Record and Print Setting Step ..................................................... 12
3-14 Reset System Setting Step............................................................................... 12
3-15 Record / Print Start and Step Operation Method.............................................. 13
3-16 Memory Full Warning.......................................................................................13
3-17 Alarm Print in Graphic Mode ............................................................................13
3-18 Scale Change in Graphic Mode........................................................................ 14
..........................................................................9
3-19 How to ConnectsTL-(A37) Analog Output Cable.............................................. 14
3-20 Setup Process Transducer (4-20mA) Mode.....................................................15
4. BATTE R Y & F U S E R E P L A C EMENT...........................................................................16
4-1 Battery Check & Replacement ........................................................................... 16
4-2 Fuse Replacement.............................................................................................16
4-3 Note.................................................................................................................... 16
5. DATAL O GGING............................................................................................................ 16
5-1 Software Installation........................................................................................... 17
5-2 Default Settings..................................................................................................21
5-3 Meter Stand alone Operation............................................................................. 36
5-4 Download Datalogger (Graphic Recorder èPC)...............................................38
5-5 Data Conversion................................................................................................. 41
5-6 On-Line Operation with PC................................................................................. 45
1. SAFETY INFORMATION
q
Read the following safety information carefully before attempting to operate or service the meter.
q The meter analog input protection voltage range is 24V ,current
range is 250V/0.5A Fuse(MAX) , maybe damage forever if overload.
Environment conditions
Altitude up to 2000 meters
Indoor use
Relatively humidity 10~80%RH
Operation temperature 0 〜 40℃ (32~104℉)
Maintenance & Clearing
Repairs or servicing not covered in this manual should only be
performed by qualified personnel.
Periodically wipe the case with a dry cloth. Do not use abrasives or
solvents on this instruments.
Do not use abrasives or solvents on this instruments.
Safety symbols
Meter is protected throughout by double insulation or reinforced insulation.
Comply with EN-61010-1
1
2. SPECIFICATION
2-1 General Specification
Display 3
LCD symbols
1342 2656724
1 2
LCD
16
8
1.
SET
2.
RS-232
3.
4.
5.
15 12 13
21
DATE
TIME
START
2227259142310
(Fig-1)
In setting mode symbol.
In RS-232 trans mi s si on m ode symbol.
Show the date of real time clock.
Show mode : month – day – year. Show t he time of re a l time clock.
Show mode is hour : minute : second. Show the start time of record / print.
Show mode is hour : minute : second.
18
19
11
28
17
20
2
6.
STOP
Show the stop time of record / print.
INTV
Show the interval time of record / print.
7.
8. DC test symbol.
9. AC test symbol.
10.
Low battery indicator.
11. mVA Analog test indicate unit.
12. G The printer working in the graphic mode.
13. T The printer working in the text mode.
14. = Memory record indicator.
15. MAX MAX Analog input indicator.
16. MIN MIN Analog input indicator.
17. LUX :LUX unit indicator.
18. Fc Feet-candle unit indicator .
19. dB dB unit indicator.
20. %RH :Relative Humidity %RH unit indicator.
21.
22. .
Printer in using
7 segments to show the read value and decimal point of
indicator
.
LCD.
23.
Negative polarity.
3
24.
HI ALARM
25.
LO ALARM
26.
HiHi ALARM
27.
LoLo ALARM
28.
,℉
Hi alarm
Lo alarm
indicator
indicator
Hi Hi alarm
Lo Lo alarm
Temperature unit
.
.
indicator
indicator
indicator
.
.
.
29. Over Load Indicator :Show or
-
Other parts
Input Protection Voltage range 24V current range 0.5A/250V
Fuse(MAX)
Operation Temperature:0℃〜40℃( 32℉〜104℉ ) & (10~ 80% RH)
and Humidity
Conserve Temperature:-10℃〜60℃(14℉〜140℉) & (10~70% RH)
and Humidity Dimensions About 250 (L) × 100 (W) × 45(H) mm Weight :About 500g with battery Printer Interval print :
00 hour : 00 mi nute : 03 second 〜23 hour :
59 minute : 59 sec
Trigger print : Print three data
(date / time / Reading)
Accessories Thermo carrying case, Test leads with alligator
clip, 2 rolls of thermo paper, 110V/220V AC to 9V DC power adapter/power cord, RS-232 cable, P.C. software disk, 6pcs 1.5V AA batteries, TL-A37 analog output cable, RS-232 convert header, Operation manual.
4
2-2 Electrical Specification
Analog test range :DCV/ACV:2V,200mV
DCA 20mA
Accuracy (at 23℃±5℃,below 80%RH)
DCè(±1%rdg+3dgts) ACè(±1%rdg+5dgts) at (50~450Hz)
Resolution 200mV/2V range is 0.1mV/1mV
20mA range is 0.01mA A / D Sample Rate 2.5 times/sec Power Source 6 pcs 1.5V# 3 battery or 9V, DC adaptor
(inside negative, outside positive)
Battery Life Approx. 100 hours (without printing) Printer Thermal printer (EPL1902 of Panasonic) MEMORY 60000 records (up to 130000 records)
5
3. PARTS & CONTROLS
3-1 The Name of Each Parts and Positions:
200mV 2V 200 mV 2V 20mA
C¢XFcLux dB
F
¢X
HiHi Hi LoLoLo
DATE TIME START STOP
13456 789
20
,
3
SETTING
FEED
SETUP
LINE MIN
CLOCK ALARM
PRINT
RECORD
,
1
TRIGGER
,
3 CONSECUTIVE
COM
mA
20mA
MAX
FUSED
600V
(Fig-2)
6
¢X ¢X
60V 24V
MAX
RH A A
UNITRANGE MAX
V
TG
INTV
1.
V
A
2.
3.
4.
200mV
C / F
HiHi
DATA
0
2V
Lux/Fc
Hi
TIME
1/2/3
200mV
dB
LoLo
START
4/5/6
2
%RH
Lo
STOP
Toggle button for ( 200mV, ℃/℉, HiHi, DATA) and digit “ o ”.
Toggle button for ( 2V, Lux/ Fc, Hi, TIME) and digit “ 1/2/3 ”.
Toggle button for ( 200mV, dB, LoLo, START) and digit “ 4/5/6 ”.
Toggle button for ( 2V, %RH, Lo, STOP) and digit “ 7/8/9 ”.
5.
6.
7/8/9
20m A/
G/T
INTV
3'SETTING
SETUP
Toggle button for ( 20mA, A / A, G / T, INTV ) button and “ ” right shift function.
Press and hold this button for 3 sec will into setting mode, press again will end setting mode.
7
7.
RANGE
FEED LINE
Feed paper in normal mode, range function in setting mode.
8.
9.
10.
11.
“ COM ” Measuring
12
13
14
“ V ” Measuring
“ mA ” Measuring
UNIT MAX
MIN
CLOCK PRINT
ALARM
=
RECORD
Socket
Socket
Socket
MAX/MIN function in normal mode “ UNIT ” function in setting mode.
In normal mode, press 1 sec is trigger print function, press and hold for 3 sec is start/stop consecutive print function, but in setting mode will be “ clock ” function.
In normal mode, press 1 sec is trigger record ( MAX 255 times), In setting mode is “ alarm ” function, press and hold over 3 sec is start/stop consecutive record function.
Power button. To connect negative lead of voltage, current.
(black color)
To connect positive lead for voltage.(red color)
To connect positive lead for current.
15
LCD
Show test value, unit symbol and range indicator.
16 Thermal Printer Printing data. 17 Acryl Putting thermal paper.
RS-232 Connector
18
RS-232 used.
19 FEED Button Feed paper into printer 20 DC 9V Socket To connect adaptor.
8
3-2 Power Status :
As battery power is not sufficient, the , will be shown on LCD replace with six new 1.5V batteries is required.
3-3 Quick Manual for Easy Set-up
STEP1 STEP2 STEP3 STEP4 STEP5
Push this button 3 second.
SETUP
Select one.
RANGE
UNIT
CLOCK
ALARM
Choose one from specified
function Bar.
2V
LUX / FC
TIME START
Hi
200mV
dB %RH
STOP
LoLo
Lo
200mV 2V
F
c
DATE
HiHi
20mA
A /
INTV
G / T
A
Reconfirm
input setting.
RANGE
UNIT CLOCK ALARM
a. You could only set up one of the functions at each time. b. To change position of point decimal, follow step1 & step2, then press button. c. To input digit, follow step1 & step3 to set the number.
Press to return normal.
SETUP
3-4 ACV、DCV and DCA Test Setting :
1. ACV 2V Test setting sequencePress and hold à press
3'SETTING
RANGE
à press
, to end setting mode.
2. ACV 200mV Test setting sequencePress and hold sec à press
3'SETTING
press
RANGE
à press
, to end setting mode.
3. DCV 2V Test setting sequencePress and hold à press
3'SETTING
RANGE
à press
, to end setting mode.
2V
à press
200mV
2V
à press
9
3'SETTING
RANGE
à press
3'SETTING
RANGE
3'SETTING
for 3 sec
à press
for 3
RANGE
for 3 sec
à press
à
4. DCV 200mV Test setting sequencePress and hold sec à press
3'SETTING
press
RANGE
à press
, to end setting mode.
200mV
à press
3'SETTING
RANGE
for 3
à
5. DCA 20mA Test setting sequencePress and hold
sec à press
3'SETTING
press
RANGE
à press
, to end setting mode.
20mA
3-5 UNIT Setting Step
1. ℃/℉ Setting steppress and hold
UNIT
press
à press
3'SETTING
, to end setting mode.
C/ F
change℃/℉ à press
2. Lux/Fc Setting steppress and hold
UNIT
press
à press
3'SETTING
Lux/Fc
change Luc/Fc à press
, to end setting mode.
3. dB Setting steppress and hold
UNIT
à press
dB
à press
to end setting mode.
4. %RH Setting steppress and hold
UNIT
à press
%RH
à press
to end setting mode.
5. / A Setting steppress and hold
UNIT
à press change A/ A à press
3'SETTING
, to end setting mode.
3'SETTING
3'SETTING
3'SETTING
UNIT
3'SETTING
UNIT
3'SETTING
à press
3'SETTING
for 3
RANGE
for 3 sec à press
UNIT
for 3 sec à press
UNIT
for 3 sec à press
à press
3'SETTING
for 3 sec à press
à press
3'SETTING
for 3 sec à press
UNIT
à press
à
à
à
,
,
3-6 ALARM Setting Step
1. HIHI ALARM Setting steppress and hold
press
ALARM
à press
shift button setting “ALARM" à press to end setting mode.
2. HI ALARM Setting steppress and hold mode à press
ALARM
HiHi
à press
10
3'SETTING
for 3 sec à
à assort 0~9 number è right
ALARM
3'SETTING
Hi
à press
fo r 3 sec into setting
à assort 0~9 number
3'SETTING
,
è right shift button setting “ALARM" à press
3'SETTING
, to end setting mode.
ALARM
à press
3. LOLO ALARM Setting steppress and hold setting mode à press
ALARM
à press
number è right shift button setting “ALARM" à press
3'SETTING
press
, to end setting mode.
4. LO ALARM Setting steppress and hold setting mode à press
ALARM
à press
number è right shift button setting “ALARM" à press
3'SETTING
press
, to end setting mode.
3'SETTING
3'SETTING
LoLo
Lo
for 3 sec into
à assort 0~9
ALARM
for 3 sec into
à assort 0~9
ALARM
3-7 Real Time Clock , Time/ Date Setting Step
1. Real time clock , date setting steppress and hold sec into setting mode à press
CLOCK
à press
assort 0~9number è right shift button setting date à press
CLOCK
à press
3'SETTING
, to end setting mode.
2. Real time clock, time setting steppress and hold sec into setting mode à press
CLOCK
à press
assort 0~9number è right shift button setting time à press
CLOCK
à press
3'SETTING
, to end setting mode.
3'SETTING
3'SETTING
for 3
DATE
for 3
TIME
3-8 Record/Print Start Time, Stop Time, Interval Time Setting Step:
à
à
à
à
1.
Start time setting step setting mode
à press
press and hold
CLOCK
à press
3'SETTING
START
number è right shift button setting start time à press
3'SETTING
press
2.Stop
time setting step setting mode 0~9number è right shift button
3'SETTING
press
3. Interval time setting steppress and hold setting mode à press number è right shift button setting in terval time à press
to end setting mode.
press and hold
à press
to end setting mode.
CLOCK
setting stop time à press
CLOCK
à press
11
3'SETTING
à press
3'SETTING
INTV
for 3 sec into
à assort
CLOCK
for 3 sec into
STOP
à
CLOCK
for 3 sec into
à assort 0~9
CLOCK
0~9
à
assort
à
à
3'SETTING
press
to end setting mode.
3-9 Print Mode Setting Step
Printer work mode setting sequencepress and hold sec into setting mode à press G/T MODE à press
3'SETTING
ALARM
, to end setting mode.
à press
3-10 Clear Record Step
3'SETTING
G/T
for 3
change
Press
=
RECORD
+
Power ON in the same time
The LCD should display “dEL”
3-11 Disable StartStopIntv and Setting Step
1.Disable START、STOP、INTV sequencepress and hold
3'SETTING
START
for 3 sec into
3'SETTING
start, stop, intv à press
for 3 sec into setting mode à press
3'SETTING
to end setting mode.
2.Disable ALARM sequencepress and hold
setting mode à press
STOP
disable alarm à press
to end setting mode.
3-12 Decimal Point Setting Step
Shift point setting sequencepress and hold enter setting mode à press
position à press
3'SETTING
to end setting mode.
INTV
3'SETTING
to change decimal point
3-13 Consecutive Record and Print Setting Step
Setting sequencepress and hold mode à press
TIME
setting / = à press
end setting mode.
If already in setting MODE, press
3'SETTING
TIME
for 3 sec to enter setting
3'SETTING
button only.
3-14 Reset System Setting Step
disable
3'SETTING
for 3 sec to
, to
Press
3'SETTING
+ Power ON
12
3-15 Record / Print Start and Step Operation Method
(1). Start way :
=
1. Trigger Record / Print : in general mode press
RECORD
one second.
2. Consecutive Record/Print :
Automatic mode :
a). Into setting mode, setting Start/Stop/Into/Time. b). Chose automate consecutive Record/Print (by 3-13 setting
way)
c). Back to general mode, on LCD = or should be
repeat.
Hand setting mode :
a). Into setting mode, disable Start, Stop, Intv. (by 3-11 stop
way) b). Into setting mode, setting Intv. c). Back to general mode.
d). Press
=
RECORD
PRINT
button 3 second, the LCD will be show
= or symbol, into consecutive Record / Print of hand
setting mode.
PRINT
or
(2). End Record/Print :
1. Automatic mode : The function will be stopped automatically while the STOP time is up.
2. Hand setting mode :To stop consecutive Record/Print by user press
=
and hold
PRINT
RECORD
symbol will be disappear.
or
PRINT
button for 3 seconds. The LCD
3-16 Memory Full Warning : The = symbol will be flash.
3-17 Alarm Print in Graphic Mode :
When printing in G mode, if you have setting any alarm points (HiHi, Hi, LoLo, Lo) when the read value over the set points, the printer the will print alarm value on the paper.
13
=
RECORD
or
3-18 Scale Change in Graphic Mode
HiHi
ALARMHiALARMLoALARM
ü No change
ü No change
ü No change
ü ü Change scale by HiHi Hi ALARM ü ü Change scale by HiHi Lo ALARM ü ü Change scale by HiHi LoLo ALARM
ü ü Change scale by Hi Lo ALARM ü ü Change scale by Hi LoLo ALARM
ü ü Change scale by Lo LoLo ALARM ü ü ü Change scale by HiHi Lo ALARM ü ü ü Change scale by HiHi LoLo ALARM ü ü ü Change scale by HiHi LoLo ALARM
ü ü ü Change scale byHi LoLo ALARM
LoLo
ALARM
ü No change
Scale change by alarm setting
ü ü ü ü Change scale by HiHi Lo ALARM
No setting ALARM, no change
ü : had setting
3-19 How to ConnectsTL-(A37) Analog Output Cable
14
Loading...
+ 43 hidden pages