Omega Products HH506A User Manual

High Accuracy Data Logger
Dual Input, Handheld Thermometer with RS232C Interface
and Software
HH506RA
Dual Input
Standard
No Points
USB Interface
Cable and Software
Optional for
HH506RA
HH506RA shown with
KHSS-18G-RSC-12 probes,
sold separately.
visit omega.com /jhin-rsc
Comes complete with RS232C
cable and software, rubber boot,
2 Type K beaded wire T/Cs, and
U 2-Channel Temperature Measuring U 7 Thermocouple Types U Triple Display with Setable Backlight U Save Data (128 Samples via Button
with Time Stamp)
U Data Logging (Up to 1024 Samples,
Interval Set from 1 Second to Hours)
U Time, Record Interval, APO Time Setting U Software Package Included (RS232C
Cable and Disk, Model HH506RA Only)
U °C/°F Switchable U 0.1 Resolution U Water/Splash Resistant,
NEMA 4X (IP56), Dustproof
operator’s manual.
Free Thermocouple Included!
All Thermocouple
Probes Sold
Separately. Visit
omega.com
The OMEGA® HH506A is a low cost, feature-packed, portable, digital thermometer that measures K, J, R, S, T, E and N thermocouples. The unit has data logging capacity in the save mode of 128 samples with time stamp via pressing the save button. In the data logging mode up to 1024 records may be logged at an interval set from 1 second to 23 hr/59 min/59 sec. Data is stored in 16 groups of 64 records. Easy to use set-up instructions allow the user to measure a broad range of T/Cs, MAX/MIN, AVG, REL, Hold Function, T1/T2. The HH506RA has the HH506A features plus it includes an RS232C interface with Windows® software.
L-27
These models include a free 1 m (40") Type K insulated beaded wire thermocouple with subminiature connector and wire spool caddy (1 per channel). Order a Spare! Model No.
SC-TT-K-30-36.
Data Logger Thermometer
Specifications HH506RA HH506A
Backlit LCD U U
No. of Digits 19999 19999
Probe (Type) K, J, T, E, R, S, N K, J, T, E, R, S, N
Range -210 to 1767°C -210 to 1767°C
(-346 to 3212°F) (-346 to 3212°F)
Resolution 0.1/1 0.1/1
Timer Real Time Real Time
Save/Log 128/1024 128/1024
Input Channel 2 2
Data/Hold U U
Max/Min U U
Relative
RS232C U N/A
Software Compatable with N/A
Display 3 3
T1-T2 U U
APO
Auto Power-Off)
Hi/Lo Limits U U
(with beeper warning)
Basic Accuracy
(rdg = reading)
(zero set) U U
Windows 98; 2000; XP
(may be disabled
U U
±(0.05% rdg + 0.3°C) ±(0.05% rdg + 0.3°C)
HH506A
Dual Input
SM
Extended Warranty
Program
OMEGACARESM extended warranty program is available for models shown on this page. Ask
your sales representative for full
details when placing an order. OMEGACARE
labor and equivalent loaners.
SM
covers parts,
Specifications
Temperature Range:
K Type: (0.1°, 1° for above 2000°F)
-200 to 1372°C (-328 to 2501°F) J Type: (0.1°, 1° for above 2000°F)
-210 to 1200°C (-346 to 2192°F) T Type: (0.1°) -200 to 400°C (-328 to 752°F) E Type: (0.1°) -210 to 1000°C (-346 to 1832°F) R Type: (1°) 0 to 1767°C (32 to 3212°F) S Type: (1°) 0 to 1767°C (32 to 3212°F) N Type: (0.1°, 1° for above 2000°F)
-50 to 1300°C (-58 to 2372°F) According to temperature standard ITS-90
Accuracy:
K/J/T/E Type: ±(0.05% rdg + 0.3°C) on -50 to 1370°C ±(0.05% rdg + 0.7°C) on -50 to -210°C ±(0.05% rdg + 0.6°F) on -58 to 2501°F ±(0.05% rdg + 1.4°F) on -58 to -346°F N Type: ±(0.05% rdg + 0.8°C) on -50 to 0°C ±(0.05% rdg + 0.4°C) on 0 to 1300°C ±(0.05% rdg + 1.6°F) on -58 to 32°F ±(0.05% rdg + 0.8°F) on 32 to 2372°F R/S Type: ±(0.05% rdg + 2°C) on 0 to 1767°C ±(0.05% rdg + 4°F) on 32 to 3212°F
Resolution: 0.1°C/1°C (0.1°F/1°F) Power: 9V battery (included) Datalogger Capacity:
Save Data: 128 samples with time stamp Data Logger: 1024 data capacity (interval 1 sec to 23:59:59)
Dimensions: 192 H x 91 W x 53 mm D
(7.6 x 3.6 x 2.2")
Weight: Approx 255 g (9 oz)
HH506A.
AVAILABLE FOR FAST DELIVERY!
To Order visit omega.com/hh506a_hh506ra for Pricing and Details
Model No. Description HH506RA Dual input data logger/RS232C/software HH506A Dual input data logger
Accessories Model No. Description
HH506RA-USB-SW USB cable and software for Win98/NT/2000
(HH506RA comes with RS232 cable and software)
SC-HH500 Soft carrying case SC-TT-K-30-36 Extra Type K beaded thermocouple, 1 m (40") KTSS-HH 150 mm (6") long 1⁄8" diameter stainless steel
Type K probe with 300 mm (12") retractable cable [expands to 1.2 m (48")] terminating with male subminiature connector (not shown)
KHSS-18G-RSC-12 Utility handle probe 300 mm (12") CAL-3-HH NIST-traceable calibration with points MN1604 Replacement 9V alkaline battery
Comes complete with 9V battery, Type K thermocouple (1 per channel), rubber boot, NIST certificate (no points) and operator’s manual. HH506RA includes software disk and RS232 cable.
Ordering Examples: HH506RA, dual input data logger/RS232C thermometer and SC-HH500, soft case.
OCW-3, OMEGACARESM extends standard 1-year warranty to a total of 4 years.
L-28