Omega Products HH501AJK User Manual

Digital Thermometers
HH500 Series
Starts at
$
All Type K Models
Supplied with Yellow
Rubber Boot
95
Types J, K ThermocouplesProvides Max/Min,
Avg, Hold, Relative
Warning Beeper with Hi/Lo
Setting, Time Setting on Model HH502
Dual Display Function 0.1° ResolutionDifferential
Thermocouple Input
Accuracy: Stated Accuracy
at 23 ±5°C <75% RH
NEMA 4X (IP56) DustproofWater/Splash Resistant
Type J or K
Thermocouple
Inputs!
Specifications (Common)
Input Type: J or K Power: One 9V battery (included) Battery Life: 200 Hours Dimensions: 192 H x 91 W x 53 mm D
(7.6 x 3.6 x 2.2")
Weight: Approx 255 g (9 oz)
(HH501AJK)
Display Type: Backlit LCD Number of Digits: 1999 Input Channel: 1 Temperature Range: -50 to 1370°C
(-58 to 1950°F)
Resolution: 0.1°/1° Display: 1 W/Bead Wire Type K Thermocouple: 1 Basic Accuracy, (% Rdg): 0.1% +1°C
(HH501BJK)
Display Type: Backlit LCD Number of Digits: 1999 Input Channel: 2 Temperature Range: -50 to 1370°C
(-58 to 1950°F
Resolution: 0.1°/1° Display: 1 W/Bead Wire Type K Thermocouple: 2 Basic Accuracy: 0.1% +1°C
HH501AJK, $95, single input thermometer, 1999 counts, backlit LCD display, Type J or K thermocouple, reading hold, max function, ITS-90 accuracy: ±0.2%.
(HH502)
Display Type: LCD Number of Digits: 25,000 Input Channel: 2 Temperature Range: -200 to 1370°C
(-328 to 2498°F)
Resolution: 0.1° Display: 3 W/Bead Wire Type K Thermocouple: 2 Basic Accuracy: 0.05% +0.3°C
L-43
(HH503)
Display Type: LCD Number of Digits: 25,000 Input Channel: 1 Temperature Range: -200 to 1370°C
(-328 to 2498°F)
Resolution: 0.1° Display: 3 W/Bead Wire Type K Thermocouple: 1 Basic Accuracy: 0.05% +0.3°C
Standard
No Points
HH501BJK
$
109
Dual Type J and K Input1999 CountsBacklit LCD Display Hold and MaxT1-T2
Dustproof and
Water/Splash
Resistant
All models shown smaller than actual size.
HH502
$
129
Dual Type
J and K Input
25,000 Counts
Resolution
Max/MinT1-T2ITS-90 Accuracy
±0.05%
HH503
$
109
J or K Input25,000 Counts ResolutionMax/Min, AVG, REL,
and Hold Functions
ITS-90 Accuracy: ±0.05%
Free Thermocouple Included!
Thermocouple models include a free 1 m (40") Type K or appropriate alternative beaded wire thermocouple with subminiature connector and wire spool caddy (1 per channel).
Order a Spare! Model No. SC-GG-K-30-36, $15.
All Thermocouple and RTD Probes Sold Separately.
See Sections A and C for More Details!
MOST POPULAR MODELS HIGHLIGHTED!
To Order
Model No. Price No. of Inputs Input Type HH501AJK $95 1 J or K HH501BJK 109 2 J or K HH502 125 2 J or K HH503 109 1 J or K SC-HH500 15 Soft Carrying case CAL-3-HH 85 NIST traceable calibration
Comes complete with protective rubber boot with tilt stand, 9V alkaline battery and operator’s manual. Temperature models include 1 or 2 beaded wire thermocouples (1 per channel).
Ordering Examples: HH501AJK, single input handheld thermometer, for J or K thermocouples, $95.
HH501BJK, dual input handheld thermometer, for J or K thermocouples, $109.
Recommended Reference Book:
Planning, Scheduling and Controlling,GE-0210
(Specify Model Number)
with points
A Systems Approach to
, $
Visit omega.com/bobi for Additional Books
100
.
L
L-44
Loading...
+ 1 hidden pages