Omega Products HH-21A User Manual

Exceptional Accuracy Digital Thermometers
Single and Dual Input Models
HH-20A Series
No Points
Holster
Included!
U Each Unit Comes with a Certificate
Stating NIST-Traceability (No Points)
U Single and Dual Input Models with
Display Hold
U Dual Input Models Feature
Trend, Min/Max and Differential Measurements
U HH-21A and HH-23A Accept J, K and
T Inputs
U HH-22A Accepts J and K Inputs U 0.1 Resolution in °F and °C Over
Full Range
U High 0.1% Reading Accuracy U Self-Diagnostics and Retention
of User Programming
U RoHS Compliant U Optional Power Supply
The HH-20A series microprocessor-based handheld thermometers offer wide-ranging temperature readings and feature state-of-the-art innovations. The easy-to-read custom 5-digit LCD readout with trend display and self-diagnostics are all standard. The case is drop/splash and dust-proof, and has a built-in tilt stand/handle for bench use or hands-free field measurements.
The HH-21A is a single input unit that accepts J, K and T thermocouple types. From the front panel, the user can select the thermocouple type, display units (°C or °F), and display resolution (0.1° or 1°). The HH-21A also has a display hold function. As with all HH-20A series units, the HH-21A features exceptionally high accuracy, 0.1% of reading plus 1°F.
The HH20-HB
holster (std)
provides additional
shock protection and a convenient
belt clip.
Spare holster
(HH20-HB).
HH-22A dual J/K input, shown smaller than actual size. Each unit supplied with 2 Type K beaded wire thermocouples, integral tilt stand, wrist strap, 9V battery, protective rubber holster (HH20-HB), NIST certificate and operator’s manual.
When you turn on an HH-20A, it remembers what you were doing; the thermocouple type, resolution, and temperature units are stored in non-volatile memory so you don’t have to reprogram every time you start up.
L-47
Specifications
Display: 5-digit LCD; custom indicators
for thermocouple type°C/°F units, hold and low battery; HH-22A and HH-23A have additional indicators for input (T1, T2, T1-T2, scan), up/down trend arrows and min/max data storage
Keypad: Momentary switches with tactile feedback; on/off, thermocouple type, units, resolution, hold; HH-22A and HH-23A have additional keys for record min/max, view min/max, stop/clear record input type (T1, T2, T1-T2, scan)
Configuration Retention: Selected readout, input type, units and resolution retained on power-off
Diagnostics: Low battery, open thermocouple, invalid keypad entry, out of range, internal hardware fault
Accuracy: 0.1% rdg + 0.6°C (1°F) Repeatability: 0.2°C for 1 week
at constant temperature
HH20SW
All Models
Resolution: 0.1° throughout
entire range Temperature Coefficient: (0.02% rdg
+ 0.1°C) below 64°F (18°C) and over 82°F (28°C); included in accuracy, between 18 and 28°C (64 and 82°F)
Ambient Temperature: 0 to 50°C (32 to 122°F), 0 to 90% RH
Reading Rate: 1 per second Max Common Mode Voltage: 42V peak
to earth ground
Power: 9 Vdc battery, alkaline (included)
The HH20SW, multiprobe switchbox allows up to 6 probes. Order below.
Battery Life: 100 h, typical, alkaline
battery Dimensions: 178 H x 74 W x 28 mm D
(7.0 x 2.9 x 1.1")
Weight: 284 g (10 oz) Accessories Included: 9 Vdc alkaline
battery, beaded wire Type K probe (for each input), integral tilt stand/ handle, wrist strap, rubber holster, NIST certificate, and operator’s manual
The HH20CAL, turns a
handheld into
a portable calibrator
for checking
calibration on other J,
K, and T instruments.
Order below.
U 6 Inputs with Rotary
Selector
U Works with a Wide
Variety of Handheld Meters
U 2-Position Output
Connector for Single and Dual Input Thermometers
U Available for J, K
and T Calibrations
Specifications
Operating Ambient: 0 to 50°C; less
than 90% RH to 35°C; reduce RH limit by 3%/°C from 35 to 50°C
Connectors: 1 male, 6 female subminiature thermocouple connectors, type SMP
Dimensions: 127 H x 71 W x 38 mm D (5 x 2.8 x 1.5")
Weight: 341 g (12 oz)
To Order
Model No. Description
HH20SW-(
SMP-(
Comes complete with operator’s manual.
Specify calibration: J, K, or T.
*
Ordering Example: HH20SW-J,
multiprobe switchbox, SMP-J-M, mating male connector.
Visit omega.com/hh20sw_21a_22a_23a for Pricing and Details
*) Multiprobe switchbox
*)-M Mating male connector
Input Ranges
Type °C Range °F Range
-210 to 760 -346 to 1400
-200 to 1372 -328 to 2502
-200 to 400 -328 to 752
AVAILABLE FOR FAST DELIVERY!
To Order visit omega.com/hh-20sw_21a_22a_23a for Pricing and Details
Model No. No. of Inputs Input Types
HH-21A 1 J/K/T
HH-22A 2 J/K HH-23A 2 J/K/T
Comes complete with beaded wire Type K probe (for each input), integral tilt stand/handle, wrist strap, 9V battery, shock resistant holster (HH20-HB) and operator’s manual.
Ordering Example: HH-22A, digital thermometer with Type J/K input, OMEGACARESM extends standard 3-year warranty to a total of 5 years.
Accessories
Model No. Description
SC-450L Soft carrying case HH20-HB Spare protective rubber holster HH22A-AC 9V NiMH battery with 110 Vac charger for
HH-21A, HH-22A or HH-23A (US plug) HH20A-U Universal 9V NiMH battery with 110 Vac
charger (with plug-in clips for USA, UK, Europe and Australia) for HH-21A, HH-22A or HH-23A
MN1604 Replacement alkaline battery CAL-3-HH (*)TSS-HH General purpose meter probe HH20CAL Portable calibrator module HH20SW-(*) Multiprobe switchbox
(*) Specify calibration J, K or T.
NIST-traceable calibration with points
Extended Warranty
Program
OMEGACARESM extended warranty program is available for models shown on this page. Ask your sales representative for full details when placing an order. OMEGACARE covers parts, labor and equivalent loaners.
SM
SM
L
L-48