Omega Products H1750 User Manual

C-89
Digital I/O to Computer Interfaces
RS-232 or RS-485 Compatible
To Order
(Specify Model Number)
Model No. Price Description
H1750 $275 24-channel digital I/O to RS-232/485 interface;
mounts directly to SSS-PC-24V backplane
H1770 350 64-channel digital I/O to RS-232/485 interface;
H1770-CA-1 100 Four cables to attach H1770 to four
SSS-PC16-B backplanes
SSS-PC16-B* 100 16-channel digital I/O module backplane,
for use with H1770; requires H1770-CA-1 cable
SSS-PC-24V* 160 24-channel digital I/O module backplane,
for use with H1750
Specifications
Channels: H1750, 24 channels; H1770,
64 channels; user can define individual channels as either input or output
Input Voltage Level: 0 to 10 V without damage
Input Switching Levels: 3.5 V min high; 1.0 V max low
Power Requirements: +5 Vdc ±0.25 V @ 30 mA max (not including I/O module requirements)
Baud Rates: 300, 600, 1200, 2400, 4800, 9600, 19.2k, 38.4k
Multidrop Capability:
Up to 124 interfaces
*Backplanes require solid state I/O modules. Each unit supplied with complete operator’s manual.
Ordering Example: H1770 64-channel digital I/O interface, H1770-CA-1 cable assembly and SSS-PC16-B digital I/O module backplane, $350 + 100 + 100 = $550.
H1750, $275, shown connected to SSS-PC-24V
H1770, $350, shown connected to SSS-PC16-B
H1700 Series
$
275
Basic Unit
Digital Inputs/Outputs via RS-232 or RS-485
Connect to Solid State I/O Modules to Sense/ Control ac/dc Voltages
Configure Each Bit Individually as Input/Output
Control Digital I/O Singly or All at Once
24 and 64-Bit Versions
Up to 24 Boards/7936 Channels on a Single RS-485 Line
The H1700 Series provides easy access to digital input and output signals through an RS-232 or RS-485 communications link. The H1750 provides 24 channels of digital I/O, while the H1770 has 64 channels. For interfacing to real­world signals, the H1700 Series is designed to work directly with OMEGA solid state I/O modules. Modules are available to sense ac or dc voltages, or to control ac or dc power lines.
The H1750 mounts directly to the OMEGA SSS-PC-24V, which accepts up to 24 I/O modules, while the H1770 connects to up to four SSS-PC16-B 16-channel backplanes.
MOST POPULAR MODELS HIGHLIGHTED
Outputs: 0 to 10 V, 15 mA max load Communications: ASCII format via
RS-232/485 ports; 7 data bits, odd, even or none parity; all communications setups stored in nonvolatile memory using EEPROM
Dimensions: 102 H x 117 mm W (4.0" x 4.6"), H1750; 127 H x 254 mm W (5.0" x 10.0"), H1770
Operating Ambient: -25 to 70°C (-13 to 158°F); 0 to 95% RH, non-condensing
Storage Ambient: -25 to 85°C (-13 to 185°F)
IBM PC
SERIAL I/O
One Omega Drive | Stamford, CT 06907 | 1-888-TC-OMEGA (1-888-826-6342) | info@omega.com
EPG05
www.omega.com
UNITED KINGDOM
www. omega.co.uk
Manchester, England
0800-488-488
UNITED STATES
www.omega.com
1-800-TC-OMEGA
Stamford, CT.
CANADA
www.omega.ca
Laval(Quebec)
1-800-TC-OMEGA
GERMANY
www.omega.de
Deckenpfronn, Germany
0800-8266342
Karviná, Czech Republic
FRANCE
www.omega.fr
Guyancourt, France
088-466-342
CZECH REPUBLIC
www.omegaeng.cz
596-311-899
BENELUX
www.omega.nl
Amstelveen, NL 0800-099-33-44
More than 100,000 Products Available!
Temperature
Calibrators, Connectors, General Test and Measurement Instruments, Glass Bulb Thermometers, Handheld Instruments for Temperature Measurement, Ice Point References, Indicating Labels, Crayons, Cements and Lacquers, Infrared Temperature Measurement Instruments, Recorders Relative Humidity Measurement Instruments, RTD Probes, Elements and Assemblies, Temperature & Process Meters, Timers and Counters, Temperature and Process Controllers and Power Switching Devices, Thermistor Elements, Probes and Assemblies,Thermocouples Thermowells and Head and Well Assemblies, Transmitters, Wire
Flow and Level
Air Velocity Indicators, Doppler Flowmeters, Level Measurement, Magnetic Flowmeters, Mass Flowmeters, Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area Flowmeters, Vortex Shedding Flowmeters
pH and Conductivity
Conductivity Instrumentation, Dissolved Oxygen Instrumentation, Environmental Instrumentation, pH Electrodes and Instruments, Water and Soil Analysis Instrumentation
Data Acquisition
Auto-Dialers and Alarm Monitoring Systems, Communication Products and Converters, Data Acquisition and Analysis Software, Data Loggers Plug-in Cards, Signal Conditioners, USB, RS232, RS485 and Parallel Port Data Acquisition Systems, Wireless Transmitters and Receivers
Pressure, Strain and Force
Displacement Transducers, Dynamic Measurement Force Sensors, Instrumentation for Pressure and Strain Measurements, Load Cells, Pressure Gauges, Pressure Reference Section, Pressure Switches, Pressure Transducers, Proximity Transducers, Regulators, Strain Gages, Torque Transducers, Valves
Heaters
Band Heaters, Cartridge Heaters, Circulation Heaters, Comfort Heaters, Controllers, Meters and Switching Devices, Flexible Heaters, General Test and Measurement Instruments, Heater Hook-up Wire, Heating Cable Systems, Immersion Heaters, Process Air and Duct, Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters
click here to go to the omega.com home page
Loading...